Chore: Add gerrit maven verify GHA workflow
[sdnc/oam.git] / platform-logic / generic-resource-api / src / main / xml / GENERIC-RESOURCE-API_vf-module-topology-operation-changeassign.xml
1 <service-logic\r
2     xmlns='http://www.onap.org/sdnc/svclogic'\r
3     xmlns:xsi='http://www.w3.org/2001/XMLSchema-instance' xsi:schemaLocation='http://www.onap.org/sdnc/svclogic ./svclogic.xsd' module='GENERIC-RESOURCE-API' version='${project.version}'>\r
4     <method rpc='vf-module-topology-operation-changeassign' mode='sync'>\r
5         <block atomic="true">\r
6             <switch test='`$vf-module-topology-operation-input.request-information.request-action`'>\r
7                 <outcome value='CreateVfModuleInstance'>\r
8                     <block></block>\r
9                 </outcome>\r
10                 <outcome value='Other'>\r
11                     <return status='failure'>\r
12                         <parameter name='ack-final' value='Y'/>\r
13                         <parameter name="error-code" value="500" />\r
14                         <parameter name="error-message" value="If svc-action is 'changeassign' then request-action must be 'CreateVfModuleInstance'" />\r
15                     </return>\r
16                 </outcome>\r
17             </switch>\r
18             <set>\r
19                 <parameter name='vnf-index' value='-1' />\r
20             </set>\r
21             <switch test='`$service-data.vnfs.vnf_length`'>\r
22                 <outcome value=''>\r
23                     <return status='failure'>\r
24                         <parameter name='ack-final' value='Y'/>\r
25                         <parameter name="error-code" value="500" />\r
26                         <parameter name="error-message" value="There are no VNFs defined in MD-SAL" />\r
27                     </return>\r
28                 </outcome>\r
29                 <outcome value='Other'>\r
30                     <for index='idx' start='0' end='`$service-data.vnfs.vnf_length`' >\r
31                         <switch test='`$service-data.vnfs.vnf[$idx].vnf-id == $vf-module-topology-operation-input.vnf-information.vnf-id`'>\r
32                             <outcome value='true'>\r
33                                 <block>\r
34                                     <set>\r
35                                         <parameter name='vnf-index' value='`$idx`' />\r
36                                     </set>\r
37                                     <break/>\r
38                                 </block>\r
39                             </outcome>\r
40                         </switch>\r
41                     </for>\r
42                 </outcome>\r
43             </switch>\r
44             <switch test='`$vnf-index`'>\r
45                 <outcome value='-1'>\r
46                     <return status='failure'>\r
47                         <parameter name='ack-final' value='Y'/>\r
48                         <parameter name="error-code" value="500" />\r
49                         <parameter name="error-message" value="`'Unable to find VNF ID ' + $vf-module-topology-operation-input.vnf-information.vnf-id + ' in MD-SAL'`" />\r
50                     </return>\r
51                 </outcome>\r
52             </switch>\r
53             <set>\r
54                 <parameter name='vf-module-index' value='-1' />\r
55             </set>\r
56             <switch test='`$service-data.vnfs.vnf[$vnf-index].vnf-data.vf-modules.vf-module_length`'>\r
57                 <outcome value=''>\r
58                     <return status='failure'>\r
59                         <parameter name='ack-final' value='Y'/>\r
60                         <parameter name="error-code" value="500" />\r
61                         <parameter name="error-message" value="`'There are no VF modules defined in MD-SAL for VNF ' + $vf-module-topology-operation-input.vnf-information.vnf-id`" />\r
62                     </return>\r
63                 </outcome>\r
64                 <outcome value='Other'>\r
65                     <for index='idx' start='0' end='`$service-data.vnfs.vnf[$vnf-index].vnf-data.vf-modules.vf-module_length`' >\r
66                         <switch test='`$service-data.vnfs.vnf[$vnf-index].vnf-data.vf-modules.vf-module[$idx].vf-module-id == $vf-module-topology-operation-input.vf-module-information.vf-module-id`'>\r
67                             <outcome value='true'>\r
68                                 <block>\r
69                                     <set>\r
70                                         <parameter name='vf-module-index' value='`$idx`' />\r
71                                     </set>\r
72                                     <break/>\r
73                                 </block>\r
74                             </outcome>\r
75                         </switch>\r
76                     </for>\r
77                 </outcome>\r
78             </switch>\r
79             <switch test='`$vf-module-index`'>\r
80                 <outcome value='-1'>\r
81                     <return status='failure'>\r
82                         <parameter name='ack-final' value='Y'/>\r
83                         <parameter name="error-code" value="500" />\r
84                         <parameter name="error-message" value="`'Unable to find VF module ID ' + $vf-module-topology-operation-input.vf-module-information.vf-module-id + ' in MD-SAL'`" />\r
85                     </return>\r
86                 </outcome>\r
87             </switch>\r
88             <call module='GENERIC-RESOURCE-API' rpc='self-serve-vf-module-forking-logic' mode='sync' ></call>\r
89             <switch test="`$ss.self-serve-flag`">\r
90                 <outcome value='true'>\r
91                     <call module='GENERIC-RESOURCE-API' rpc='self-serve-vfmodule-changeassign' mode='sync' >\r
92                         <outcome value='failure'>\r
93                             <return status='failure'>\r
94                                 <parameter name='error-code' value='500' />\r
95                                 <parameter name='error-message' value="`'Encountered error performing changeassign for self-serve vf-module resources with error: '+ $error-message`" />\r
96                             </return>\r
97                         </outcome>\r
98                         <outcome value='success'>\r
99                             <return status='success'>\r
100                                 <parameter name="ack-final-indicator" value="Y" />\r
101                                 <parameter name="error-code" value="200" />\r
102                                 <parameter name="error-message" value="`$error-message`" />\r
103                             </return>\r
104                         </outcome>\r
105                     </call>\r
106                 </outcome>\r
107                 <outcome value='false'>\r
108                     <block atomic="true">\r
109                         <switch test='`$vf-module-topology-operation-input.vf-module-information.onap-model-information.model-customization-uuid`'>\r
110                             <outcome value=''>\r
111                                 <return status='failure'>\r
112                                     <parameter name='ack-final' value='Y'/>\r
113                                     <parameter name="error-code" value="500" />\r
114                                     <parameter name="error-message" value="vf-module-information.onap-model-information.model-customization-uuid is a required input" />\r
115                                 </return>\r
116                             </outcome>\r
117                         </switch>\r
118                         <get-resource plugin='org.onap.ccsdk.sli.adaptors.resource.sql.SqlResource' resource='SQL'\r
119   key='SELECT * from VF_MODULE_MODEL WHERE customization_uuid = $vf-module-topology-operation-input.vf-module-information.onap-model-information.model-customization-uuid'\r
120   pfx='db.vf-module-model'>\r
121                             <outcome value='failure'>\r
122                                 <return status='failure'>\r
123                                     <parameter name='ack-final' value='Y'/>\r
124                                     <parameter name="error-code" value="500" />\r
125                                     <parameter name="error-message" value="Error reading VF_MODULE_MODEL table" />\r
126                                 </return>\r
127                             </outcome>\r
128                             <outcome value='not-found'>\r
129                                 <return status='failure'>\r
130                                     <parameter name='ack-final' value='Y'/>\r
131                                     <parameter name="error-code" value="500" />\r
132                                     <parameter name="error-message" value="`'No model found for VF module customization UUID ' + $vf-module-topology-operation-input.vf-module-information.onap-model-information.model-customization-uuid`" />\r
133                                 </return>\r
134                             </outcome>\r
135                         </get-resource>\r
136                         <set>\r
137                             <parameter name='service-data.vnfs.vnf[$vnf-index].vnf-data.vf-modules.vf-module[$vf-module-index].vf-module-data.vf-module-information.onap-model-information.'\r
138    value='$vf-module-topology-operation-input.vf-module-information.onap-model-information.' />\r
139                         </set>\r
140                         <set>\r
141                             <parameter name='service-data.vnfs.vnf[$vnf-index].vnf-data.vf-modules.vf-module[$vf-module-index].vf-module-data.vf-module-level-oper-status.order-status'\r
142   value='Created' />\r
143                             <parameter name='service-data.vnfs.vnf[$vnf-index].vnf-data.vf-modules.vf-module[$vf-module-index].vf-module-data.vf-module-level-oper-status.last-rpc-action'\r
144   value='`$vf-module-topology-operation-input.sdnc-request-header.svc-action`' />\r
145                             <parameter name='service-data.vnfs.vnf[$vnf-index].vnf-data.vf-modules.vf-module[$vf-module-index].vf-module-data.vf-module-level-oper-status.last-action'\r
146   value='`$vf-module-topology-operation-input.request-information.request-action`' />\r
147                         </set>\r
148                         <return status='success'>\r
149                             <parameter name="ack-final-indicator" value="Y" />\r
150                             <parameter name="error-code" value="200" />\r
151                             <parameter name="error-message" value="`$error-message`" />\r
152                         </return>\r
153                     </block>\r
154                 </outcome>\r
155             </switch>\r
156         </block>\r
157     </method>\r
158 </service-logic>