Rollback port no. 47/43947/2
authorxg353y <xg353y@intl.att.com>
Fri, 20 Apr 2018 14:44:09 +0000 (16:44 +0200)
committerxg353y <xg353y@intl.att.com>
Fri, 20 Apr 2018 15:35:04 +0000 (17:35 +0200)
Roll back the default port for policy, sdc and dcae

Issue-ID: CLAMP-153
Change-Id: I750def8dabd0d45eda1c68fb592259cf8cfb7cbd
Signed-off-by: xg353y <xg353y@intl.att.com>
src/main/resources/application.properties

index d6be03c..c1c0116 100644 (file)
@@ -125,9 +125,9 @@ clamp.config.sdc.decode.service_ids=classpath:/clds/templates/sdc-decode-service
 #\r
 #\r
 # Configuration Settings for Policy Engine Components\r
-clamp.config.policy.pdpUrl1=http://policy.api.simpledemo.onap.org:8085/pdp/ , testpdp, alpha123\r
-clamp.config.policy.pdpUrl2=http://policy.api.simpledemo.onap.org:8085/pdp/ , testpdp, alpha123\r
-clamp.config.policy.papUrl=http://policy.api.simpledemo.onap.org:8085/pap/ , testpap, alpha123\r
+clamp.config.policy.pdpUrl1=http://policy.api.simpledemo.onap.org:8081/pdp/ , testpdp, alpha123\r
+clamp.config.policy.pdpUrl2=http://policy.api.simpledemo.onap.org:8081/pdp/ , testpdp, alpha123\r
+clamp.config.policy.papUrl=http://policy.api.simpledemo.onap.org:8081/pap/ , testpap, alpha123\r
 clamp.config.policy.notificationType=websocket\r
 clamp.config.policy.notificationUebServers=localhost\r
 clamp.config.policy.notificationTopic=\r
@@ -181,9 +181,9 @@ clamp.config.op.eNodeB.limit=2
 clamp.config.op.eNodeB.period=10s\r
 #\r
 # Sdc service properties\r
-clamp.config.sdc.catalog.url=http://sdc.api.simpledemo.onap.org:8085/sdc/v1/catalog/\r
-clamp.config.sdc.hostUrl=http://sdc.api.simpledemo.onap.org:8085\r
-clamp.config.sdc.serviceUrl=http://sdc.api.simpledemo.onap.org:8085/sdc/v1/catalog/services\r
+clamp.config.sdc.catalog.url=http://sdc.api.simpledemo.onap.org:8080/sdc/v1/catalog/\r
+clamp.config.sdc.hostUrl=http://sdc.api.simpledemo.onap.org:8080\r
+clamp.config.sdc.serviceUrl=http://sdc.api.simpledemo.onap.org:8080/sdc/v1/catalog/services\r
 clamp.config.sdc.serviceUsername=clamp\r
 clamp.config.sdc.servicePassword=b7acccda32b98c5bb7acccda32b98c5b05D511BD6D93626E90D18E9D24D9B78CD34C7EE8012F0A189A28763E82271E50A5D4EC10C7D93E06E0A2D27CAE66B981\r
 clamp.config.sdc.artifactLabel=blueprintclampcockpit\r
@@ -207,12 +207,12 @@ clamp.config.action.insert.test.event=false
 clamp.config.clds.service.cache.invalidate.after.seconds=120\r
 \r
 #DCAE Inventory Url Properties\r
-clamp.config.dcae.inventory.url=http://dcae.api.simpledemo.onap.org:8085\r
+clamp.config.dcae.inventory.url=http://dcae.api.simpledemo.onap.org:8080\r
 clamp.config.dcae.intentory.retry.interval=10000\r
 clamp.config.dcae.intentory.retry.limit=3\r
 \r
 #DCAE Dispatcher Url Properties\r
-clamp.config.dcae.dispatcher.url=http://dcae.api.simpledemo.onap.org:8085\r
+clamp.config.dcae.dispatcher.url=http://dcae.api.simpledemo.onap.org:8080\r
 clamp.config.dcae.header.requestId = X-ECOMP-RequestID\r
 \r
 #Define user permission related parameters, the permission type can be changed but MUST be redefined in clds-users.properties in that case !\r