Remove dependency on vfc/db
[integration/csit.git] / plans / vfc-gvnfm-vnfmgr / sanity-check / setup.sh
index 22dd8ae..b66662b 100755 (executable)
@@ -19,7 +19,6 @@
 
 source ${SCRIPTS}/common_functions.sh
 
-
 #start msb
 docker run -d -p 8500:8500  --name msb_consul consul:0.9.3
 MSB_CONSUL_IP=`get-instance-ip.sh msb_consul`
@@ -31,10 +30,16 @@ docker run -d -p 80:80 -e CONSUL_IP=$MSB_CONSUL_IP -e SDCLIENT_IP=$MSB_DISCOVERY
 MSB_IAG_IP=`get-instance-ip.sh msb_internal_apigateway`
 echo MSB_IAG_IP=${MSB_IAG_IP}
 
-docker run -d -p 3306:3306 --name vfc-db nexus3.onap.org:10001/onap/vfc/db
+# Start Mysql
+docker run -d -p 3306:3306 --name vfc-db -v /var/lib/mysql -e MYSQL_USER="gvnfm" -e MYSQL_PASSWORD="gvnfm" -e MYSQL_ROOT_PASSWORD=root -e MYSQL_DATABASE="gvnfm" nexus3.onap.org:10001/library/mariadb
 VFC_DB_IP=`get-instance-ip.sh vfc-db`
 echo VFC_DB_IP=${VFC_DB_IP}
 
+# Start Redis
+docker run -d -p 6379:6379 --name vfc-redis redis
+VFC_REDIS_IP=`get-instance-ip.sh vfc-redis`
+echo VFC_REDIS_IP=${VFC_REDIS_IP}
+
 # Wait for initialization(8500 Consul, 10081 Service Registration & Discovery, 80 api gateway)
 for i in {1..10}; do
     curl -sS -m 1 ${MSB_CONSUL_IP}:8500 && curl -sS -m 1 ${MSB_DISCOVERY_IP}:10081 && curl -sS -m 1 ${MSB_IAG_IP}:80 && break
@@ -54,7 +59,7 @@ echo sleep 60
 sleep 60
 
 # start vfc-vnflcm
-docker run -d --name vfc-vnflcm -e MSB_ADDR=${MSB_IAG_IP}:80 -e MYSQL_ADDR=${VFC_DB_IP}:3306 nexus3.onap.org:10001/onap/vfc/vnflcm
+docker run -d --name vfc-vnflcm -e MSB_ADDR=${MSB_IAG_IP}:80 -e MYSQL_ADDR=${VFC_DB_IP}:3306 -e REDIS_HOST=${VFC_REDIS_IP} nexus3.onap.org:10001/onap/vfc/vnflcm
 VNFLCM_IP=`get-instance-ip.sh vfc-vnflcm`
 
 # Wait for initialization
@@ -65,7 +70,7 @@ for i in {1..10}; do
 done
 
 # start vfc-vnfres
-docker run -d --name vfc-vnfmgr -e MSB_ADDR=${MSB_IAG_IP}:80 -e MYSQL_ADDR=${VFC_DB_IP}:3306 nexus3.onap.org:10001/onap/vfc/vnfmgr
+docker run -d --name vfc-vnfmgr -e MSB_ADDR=${MSB_IAG_IP}:80 -e MYSQL_ADDR=${VFC_DB_IP}:3306 -e REDIS_HOST=${VFC_REDIS_IP} nexus3.onap.org:10001/onap/vfc/vnfmgr
 VNFMGR_IP=`get-instance-ip.sh vfc-vnfmgr`
 
 # Wait for initialization