:depth: 3\r
 ..\r
 \r
-   **VNFM API**\r
+   **GVNFM Northbound & Southbound APIs**\r
    **V0.1**\r
 \r
 **1 Scope**\r
 =============\r
 \r
-    The scope of the present document is to describe the VNFM exposed\r
-    API specification over Or-Vnfm Reference Point.\r
+    The scope of the present document is to describe the GVNFM exposed\r
+    API specification over Or-Vnfm reference point and Ve-Vnfm-vnf reference point.\r
 \r
 **2 Terms, Definitions and Abbreviations**\r
 ===========================================\r
 \r
 Table 2-1 abbreviations\r
 \r
-**3. Interfaces provided by VNFM**  (Or-Vnfm/Ve-Vnfm-vnf) \r
+**3. Interfaces provided by GVNFM**  (Or-Vnfm) \r
 ==========================================================\r
 \r
    Interfaces use RESTful API and the format is as follows:\r
 
 \r
 **1.  Scope**\r
 ==============\r
-The scope of the present document is to describe the VNFM Driver exposed API specification.\r
+The scope of the present document is to describe the VNFM driver integrated related API specification.\r
 \r
 **2.  Terms, Definitions and Abbreviations**\r
 =============================================\r
 http(s)://[hostname][:port]/api/{vnfmtype}/v1/{vnfm_id}/[……]\r
 R1 vnfmtype:\r
 zte-vnfm\r
-fw-vnfm\r
+hw-vnfm\r
 juju\r
 \r
 **3.1  Instantiate VNF**\r
 +---------------+------------------------------------------------------------------+\r
 | IF Definition |  Description                                                     |\r
 +===============+==================================================================+\r
-| URI           | http(s)://[hostname][:port]/api//nslcm/v1/ns/grantvnf            |\r
+| URI           | http(s)://[hostname][:port]/api/nslcm/v1/ns/grantvnf             |\r
 +---------------+------------------------------------------------------------------+\r
 | Operation     |  POST                                                            |\r
 +---------------+------------------------------------------------------------------+\r
 +---------------+------------------------------------------------------------------+\r
 | IF Definition |  Description                                                     |\r
 +===============+==================================================================+\r
-| URI           | http(s)://[hostname][:port]/api/nslcm/v1/vnfs/                   |\r
+| URI           | http(s)://[hostname][:port]/api/nslcm/v1/ns/{vnfmid}/vnfs/       |\r
 |               | {vnfInstanceId}/Notify                                           |\r
 +---------------+------------------------------------------------------------------+\r
 | Operation     |  POST                                                            |\r
 
 List VF-C APIs offered.
 
 
-NS LCM API
+VFC Northbound API
 ----------
 
 Network services lifecycle management APIs
    NSLCM_API/index
 
 
-VNFM Driver API 
+VNFM Integration APIs 
 ---------------
 
-VNFM Driver component northbound APIs
+VNFM Driver Integration Related APIs
 
 .. toctree:: 
    :maxdepth: 1
 
 
 
-VNF LCM API
+GVNFM Northbound & Southbound APIs
 -----------
 
-VNF lifecycle management APIs
+GVNFM Northbound & Southbound APIs for VNF Integration
 
 .. toctree:: 
    :maxdepth: 1