X-Git-Url: https://gerrit.onap.org/r/gitweb?a=blobdiff_plain;f=sdnr%2Fwt%2Fdevicemanager%2Fprovider%2Fsrc%2Fmain%2Fresources%2Felasticsearch%2Findex%2Fmwtn%2FmodelDescription%2Fg.874.1-model.schema-information.json;fp=sdnr%2Fwt%2Fdevicemanager%2Fprovider%2Fsrc%2Fmain%2Fresources%2Felasticsearch%2Findex%2Fmwtn%2FmodelDescription%2Fg.874.1-model.schema-information.json;h=0000000000000000000000000000000000000000;hb=8404b495de1770617d745ab488116714e9d2d06d;hp=b8e4d4ab6b9ddb1bdf3bfef387887bd2018fefe3;hpb=159de601758f7cedcef9359da471f182dcf73781;p=ccsdk%2Ffeatures.git diff --git a/sdnr/wt/devicemanager/provider/src/main/resources/elasticsearch/index/mwtn/modelDescription/g.874.1-model.schema-information.json b/sdnr/wt/devicemanager/provider/src/main/resources/elasticsearch/index/mwtn/modelDescription/g.874.1-model.schema-information.json deleted file mode 100644 index b8e4d4ab6..000000000 --- a/sdnr/wt/devicemanager/provider/src/main/resources/elasticsearch/index/mwtn/modelDescription/g.874.1-model.schema-information.json +++ /dev/null @@ -1,602 +0,0 @@ -{ - "schema-information": { - "otn-current-data": { - "id": "otn-current-data", - "uml-id": "_OxyHAOGJEeGhaeLtr7IxXg", - "uml-type": "uml:Class", - "is-read-only": false, - "description": [ - "This object class is an abstract class from which the OTN layer-specific CurrentData object classes are inherited. This object class is a subclass of the Q.822 CurrentData object class, which in turn is a subclass of X.739 Scanner object class. It inherits the following attributes: scannerId, operationalState, granularityPeriod, administrativeState, suspectIntervalFlag, elapsedTime, observedObjectClass, and observedObjectInstance." - ], - "uml-name": "OTN_CurrentData" - }, - "timestamp": { - "id": "timestamp", - "uml-id": "_bGwfoOGJEeGhaeLtr7IxXg", - "uml-type": "ownedAttribute", - "type": "_X-HZUNwbEeGoneTbGt8X0A", - "order-number": 1, - "is-read-only": false, - "description": [ - "The timestamp associated with when the current data was collected." - ], - "uml-name": "timestamp" - }, - "otn-history-data": { - "id": "otn-history-data", - "uml-id": "_dQ2mYOGOEeGhaeLtr7IxXg", - "uml-type": "uml:Class", - "is-read-only": false, - "description": [ - "This object class is an abstract class from which the OTN layer-specific HistoryData object classes are inherited." - ], - "uml-name": "OTN_HistoryData" - }, - "suspect-interval-flag": { - "id": "suspect-interval-flag", - "uml-id": "_M8IDNceIEeSfd5vyUJsimg", - "uml-type": "ownedAttribute", - "type": "pathmap://UML_LIBRARIES/UMLPrimitiveTypes.library.uml#Boolean", - "order-number": 1, - "is-read-only": false, - "description": [ - "This attribute is used to indicate that the performance data for the current period may not be reliable. Some reasons for this to occur are:- Suspect data were detected by the actual resource doing data collection.- Transition of the administrativeState attribute to/from the 'lock' state.- Transition of the operationalState to/from the 'disabled' state.- Scheduler setting that inhibits the collection function.- The performance counters were reset during the interval.- The currentData (or subclass) object instance was created during the monitoring period." - ], - "uml-name": "suspectIntervalFlag", - "controlType": "checkbox" - }, - "«q.822»-current-data": { - "id": "«q.822»-current-data", - "uml-id": "_M8IDMceIEeSfd5vyUJsimg", - "uml-type": "uml:Class", - "is-read-only": false, - "uml-name": "«Q.822»-CurrentData" - }, - "elapsed-time": { - "id": "elapsed-time", - "uml-id": "_M8IDOMeIEeSfd5vyUJsimg", - "uml-type": "ownedAttribute", - "type": "pathmap://UML_LIBRARIES/UMLPrimitiveTypes.library.uml#Integer", - "order-number": 2, - "is-read-only": false, - "uml-name": "elapsedTime", - "controlType": "number" - }, - "«q.822»-history-data": { - "id": "«q.822»-history-data", - "uml-id": "_M8IDVMeIEeSfd5vyUJsimg", - "uml-type": "uml:Class", - "is-read-only": false, - "uml-name": "«Q.822»-HistoryData" - }, - "history-data-id": { - "id": "history-data-id", - "uml-id": "_M8IDWMeIEeSfd5vyUJsimg", - "uml-type": "ownedAttribute", - "type": "pathmap://UML_LIBRARIES/UMLPrimitiveTypes.library.uml#String", - "order-number": 1, - "is-read-only": false, - "uml-name": "historyDataId", - "controlType": "text" - }, - "period-end-time": { - "id": "period-end-time", - "uml-id": "_M8IDWceIEeSfd5vyUJsimg", - "uml-type": "ownedAttribute", - "type": "../OnfModel-CoreModel/CoreModel.uml#_oGqi1lLNEeO75dO39GbF8Q", - "order-number": 2, - "is-read-only": false, - "uml-name": "periodEndTime" - }, - "granularity-period": { - "id": "granularity-period", - "uml-id": "_M8IDWseIEeSfd5vyUJsimg", - "uml-type": "ownedAttribute", - "type": "_Y6WUEEamEeabNPX3o7rjtw", - "order-number": 2, - "is-read-only": false, - "uml-name": "granularityPeriod", - "controlType": [ - "unknown", - "period-15-min", - "period-24-hours" - ] - }, - "«x.739»-scanner": { - "id": "«x.739»-scanner", - "uml-id": "_7wb90ceIEeSfd5vyUJsimg", - "uml-type": "uml:Class", - "is-read-only": false, - "uml-name": "«X.739»-Scanner" - }, - "scanner-id": { - "id": "scanner-id", - "uml-id": "_7wb91ceIEeSfd5vyUJsimg", - "uml-type": "ownedAttribute", - "type": "pathmap://UML_LIBRARIES/UMLPrimitiveTypes.library.uml#String", - "order-number": 1, - "is-read-only": false, - "uml-name": "scannerId", - "controlType": "text" - }, - "administrative-state": { - "id": "administrative-state", - "uml-id": "_7wb92seIEeSfd5vyUJsimg", - "uml-type": "ownedAttribute", - "type": "../OnfModel-CoreModel/CoreModel.uml#_KSKOYLEuEeSZUdYfPSdgew", - "order-number": 3, - "is-read-only": false, - "uml-name": "administrativeState" - }, - "«x.721»-top": { - "id": "«x.721»-top", - "uml-id": "_BMJ0EceTEeS6-cawxfHpnA", - "uml-type": "uml:Class", - "is-read-only": false, - "description": [ - "This is the top level of managed object class hierarchy and every other managed object class is a specialization of either this generic class (top) or a specialization of subclass of top. The parameter miscellaneousError is to be used when a processing failure has occurred and the error condition encountered does not match any of object's defined specific error types." - ], - "uml-name": "«X.721»-Top" - }, - "object-class": { - "id": "object-class", - "uml-id": "_BMJ0FceTEeS6-cawxfHpnA", - "uml-type": "ownedAttribute", - "type": "_ltGzFMeUEeS6-cawxfHpnA", - "order-number": 1, - "is-read-only": false, - "description": [ - "ObjectClass ::= CHOICE{ globalForm [0] OBJECT IDENTIFIER, localForm [1] INTEGER}" - ], - "uml-name": "objectClass" - }, - "name-binding": { - "id": "name-binding", - "uml-id": "_BMJ0F8eTEeS6-cawxfHpnA", - "uml-type": "ownedAttribute", - "type": "_ltGzFMeUEeS6-cawxfHpnA", - "order-number": 2, - "is-read-only": false, - "uml-name": "nameBinding" - }, - "date-and-time": { - "id": "date-and-time", - "uml-id": "_X-HZUNwbEeGoneTbGt8X0A", - "uml-type": "uml:DataType", - "description": [ - "This primitive type defines the date and time according to the following structure: yyyyMMddhhmmss.s[Z|{+|-}HHMm] where: yyyy 0000 .. 9999 year MM 01 .. 12 month dd 01 .. 31 day hh 00 .. 23 hour mm 00 .. 59 minute ss 00 .. 59 second s .0 .. .9 tenth of second (set to .0 if EMS or NE cannot support this granularity) Z Z indicates UTC (rather than local time) {+|-} + or - delta from UTC HH 00 .. 23 time zone difference in hours Mm 00 .. 59 time zone difference in minutes." - ], - "uml-name": "DateAndTime" - }, - "5-g6-yq-oo-ee-cj-nnlz-cc6-mew": { - "id": "5-g6-yq-oo-ee-cj-nnlz-cc6-mew", - "uml-id": "_5G6YQOo-EeCjNNLZCc6mew", - "enum": [ - "SINK", - "SOURCE", - "BIDIRECTIONAL" - ], - "is-read-only": false, - "description": [ - "The enumeration with the options for directionality of the termination point." - ], - "uml-name": "_5G6YQOo-EeCjNNLZCc6mew" - }, - "r-u8-a-m-opf-ee-cj-nnlz-cc6-mew": { - "id": "r-u8-a-m-opf-ee-cj-nnlz-cc6-mew", - "uml-id": "_rU8aMOpfEeCjNNLZCc6mew", - "enum": [ - "GCC1", - "GCC2", - "GCC1_AND_GCC2" - ], - "is-read-only": false, - "description": [ - "This enumeration indicates the GCC access represented by the entity." - ], - "uml-name": "_rU8aMOpfEeCjNNLZCc6mew" - }, - "w7-1-o-opi-ee-cj-nnlz-cc6-mew": { - "id": "w7-1-o-opi-ee-cj-nnlz-cc6-mew", - "uml-id": "_W7-1oOpiEeCjNNLZCc6mew", - "enum": [ - "ENABLED", - "DISABLED" - ], - "is-read-only": false, - "description": [ - "The list of valid operational states for the connection." - ], - "uml-name": "_W7-1oOpiEeCjNNLZCc6mew" - }, - "g0-z-cs-os-d-ee-cj-nnlz-cc6-mew": { - "id": "g0-z-cs-os-d-ee-cj-nnlz-cc6-mew", - "uml-id": "_g0zCsOsDEeCjNNLZCc6mew", - "enum": [ - "REVERTIVE", - "NON-REVERTIVE" - ], - "is-read-only": false, - "description": [ - "The operation type associated with the protection mechanism (either non-revertive or revertive)." - ], - "uml-name": "_g0zCsOsDEeCjNNLZCc6mew" - }, - "jl09-g-os-k-ee-cj-nnlz-cc6-mew": { - "id": "jl09-g-os-k-ee-cj-nnlz-cc6-mew", - "uml-id": "_Jl09gOsKEeCjNNLZCc6mew", - "enum": [ - "EXERCISE", - "MANUAL_SWITCH", - "FORCED_SWITCH", - "LOCKOUT", - "RELEASE_OF_MANUAL_SWITCH", - "RELEASE_OF_FORCED_SWITCH", - "RELEASE_OF_LOCKOUT" - ], - "is-read-only": false, - "description": [ - "This enumeration contains the options for the actions that instruct the protection system for performing specific protection switching operations." - ], - "uml-name": "_Jl09gOsKEeCjNNLZCc6mew" - }, - "bwx-bq-ow5-ee-cj-nnlz-cc6-mew": { - "id": "bwx-bq-ow5-ee-cj-nnlz-cc6-mew", - "uml-id": "_bwxBQOw5EeCjNNLZCc6mew", - "enum": [ - "UNLOCKED", - "LOCKED", - "SHUTTING_DOWN" - ], - "is-read-only": false, - "description": [ - "For more information on Administrative State, See ITU-T Recs. X.731 and M.3100." - ], - "uml-name": "_bwxBQOw5EeCjNNLZCc6mew" - }, - "ch-q5-o-ow-ee-cj-nnlz-cc6-mew": { - "id": "ch-q5-o-ow-ee-cj-nnlz-cc6-mew", - "uml-id": "_ChQ5oOw-EeCjNNLZCc6mew", - "enum": [ - "2.5_G", - "10_G", - "40_G", - "100_G" - ], - "is-read-only": false, - "description": [ - "Provides an enumeration with the meaning of each k value." - ], - "uml-name": "_ChQ5oOw-EeCjNNLZCc6mew" - }, - "z-bty-u-ow-ee-cj-nnlz-cc6-mew": { - "id": "z-bty-u-ow-ee-cj-nnlz-cc6-mew", - "uml-id": "_ZBtyUOw_EeCjNNLZCc6mew", - "enum": [ - "DAPI", - "SAPI", - "BOTH" - ], - "is-read-only": false, - "description": [ - "List of modes for trace identifier mismatch detection." - ], - "uml-name": "_ZBtyUOw_EeCjNNLZCc6mew" - }, - "hf864-ox-a-ee-cj-nnlz-cc6-mew": { - "id": "hf864-ox-a-ee-cj-nnlz-cc6-mew", - "uml-id": "_HF864OxAEeCjNNLZCc6mew", - "enum": [ - "LOS_P", - "OCI", - "SSF_P", - "SSF_O", - "SSF", - "TIM", - "DEG", - "BDI" - ], - "is-read-only": false, - "description": [ - "The valid list of problems for the entity." - ], - "uml-name": "_HF864OxAEeCjNNLZCc6mew" - }, - "w-po-no-o3-e-ee-cj-nnlz-cc6-mew": { - "id": "w-po-no-o3-e-ee-cj-nnlz-cc6-mew", - "uml-id": "_WPoNoO3eEeCjNNLZCc6mew", - "enum": [ - "INTRUSIVE", - "NON-INTRUSIVE" - ], - "is-read-only": false, - "description": [ - "Monitoring types for the tandem connection monitoring function." - ], - "uml-name": "_WPoNoO3eEeCjNNLZCc6mew" - }, - "oi-7-w-o6-q-ee-cj-nnlz-cc6-mew": { - "id": "oi-7-w-o6-q-ee-cj-nnlz-cc6-mew", - "uml-id": "_OI-7wO6QEeCjNNLZCc6mew", - "enum": [ - "OPERATIONAL", - "TRANSPARENT", - "MONITOR" - ], - "is-read-only": false, - "description": [ - "List of value modes for the sink side of the tandem connection monitoring function." - ], - "uml-name": "_OI-7wO6QEeCjNNLZCc6mew" - }, - "zn-m8-c-o6-z-ee-cj-nnlz-cc6-mew": { - "id": "zn-m8-c-o6-z-ee-cj-nnlz-cc6-mew", - "uml-id": "_ZnM8cO6ZEeCjNNLZCc6mew", - "enum": [ - "40_G", - "100_G" - ], - "is-read-only": false, - "description": [ - "Provides an enumeration with the meaning of each k value." - ], - "uml-name": "_ZnM8cO6ZEeCjNNLZCc6mew" - }, - "p-v-f8-o6-a-ee-cj-nnlz-cc6-mew": { - "id": "p-v-f8-o6-a-ee-cj-nnlz-cc6-mew", - "uml-id": "_pV-F8O6aEeCjNNLZCc6mew", - "enum": [ - "LOS", - "LOL" - ], - "is-read-only": false, - "description": [ - "The valid list of problems for the entity." - ], - "uml-name": "_pV-F8O6aEeCjNNLZCc6mew" - }, - "qw1-syo6-b-ee-cj-nnlz-cc6-mew": { - "id": "qw1-syo6-b-ee-cj-nnlz-cc6-mew", - "uml-id": "_QW1SYO6bEeCjNNLZCc6mew", - "enum": [ - "LOS" - ], - "is-read-only": false, - "description": [ - "The valid list of problems for the entity." - ], - "uml-name": "_QW1SYO6bEeCjNNLZCc6mew" - }, - "o-ouk-o6-b-ee-cj-nnlz-cc6-mew": { - "id": "o-ouk-o6-b-ee-cj-nnlz-cc6-mew", - "uml-id": "_o-oukO6bEeCjNNLZCc6mew", - "enum": [ - "2.5_G", - "10_G", - "40_G", - "2.5_10_G", - "10_40_G", - "2.5_10_40_G" - ], - "is-read-only": false, - "description": [ - "Provides an enumeration with the meaning of each k value." - ], - "uml-name": "_o-oukO6bEeCjNNLZCc6mew" - }, - "krcg4-o6-d-ee-cj-nnlz-cc6-mew": { - "id": "krcg4-o6-d-ee-cj-nnlz-cc6-mew", - "uml-id": "_KRCG4O6dEeCjNNLZCc6mew", - "enum": [ - "INTRA_DOMAIN", - "INTER_DOMAIN" - ], - "is-read-only": false, - "description": [ - "This enumeration provides the options for the interface associated with OTMn." - ], - "uml-name": "_KRCG4O6dEeCjNNLZCc6mew" - }, - "eo-py-io6-q-ee-cj-nnlz-cc6-mew": { - "id": "eo-py-io6-q-ee-cj-nnlz-cc6-mew", - "uml-id": "_EOPyIO6qEeCjNNLZCc6mew", - "enum": [ - "INTRA_OFFICE", - "SHORTHAUL", - "LONGHAUL" - ], - "is-read-only": false, - "description": [ - "The valid options for reach of the optical cable." - ], - "uml-name": "_EOPyIO6qEeCjNNLZCc6mew" - }, - "6-bt3-qo6-q-ee-cj-nnlz-cc6-mew": { - "id": "6-bt3-qo6-q-ee-cj-nnlz-cc6-mew", - "uml-id": "_6Bt3QO6qEeCjNNLZCc6mew", - "enum": [ - "ON", - "OFF" - ], - "is-read-only": false, - "description": [ - "The enumeration of the options for the Automatic Power Reduction Status." - ], - "uml-name": "_6Bt3QO6qEeCjNNLZCc6mew" - }, - "f-lz-nqo6-v-ee-cj-nnlz-cc6-mew": { - "id": "f-lz-nqo6-v-ee-cj-nnlz-cc6-mew", - "uml-id": "_FLzNQO6vEeCjNNLZCc6mew", - "enum": [ - "BDI_P", - "BDI_O", - "BDI", - "TIM", - "LOS_P", - "LOS_O", - "LOS" - ], - "is-read-only": false, - "description": [ - "The valid list of problems for the entity." - ], - "uml-name": "_FLzNQO6vEeCjNNLZCc6mew" - }, - "na-el-yo6-w-ee-cj-nnlz-cc6-mew": { - "id": "na-el-yo6-w-ee-cj-nnlz-cc6-mew", - "uml-id": "_NAElYO6wEeCjNNLZCc6mew", - "enum": [ - "REGULAR", - "NONE", - "VENDOR_SPECIFIC", - "FUNCTIONALLY_STANDARDIZED" - ], - "is-read-only": false, - "description": [ - "The adaptation options for OTUk_ConnectionTermationPoints." - ], - "uml-name": "_NAElYO6wEeCjNNLZCc6mew" - }, - "wg-r-hc-o6-w-ee-cj-nnlz-cc6-mew": { - "id": "wg-r-hc-o6-w-ee-cj-nnlz-cc6-mew", - "uml-id": "_wgRHcO6wEeCjNNLZCc6mew", - "enum": [ - "2.5_G", - "10_G", - "40_G", - "100_G" - ], - "is-read-only": false, - "description": [ - "Provides an enumeration with the meaning of each k value." - ], - "uml-name": "_wgRHcO6wEeCjNNLZCc6mew" - }, - "6-y-g-eo6-w-ee-cj-nnlz-cc6-mew": { - "id": "6-y-g-eo6-w-ee-cj-nnlz-cc6-mew", - "uml-id": "_6Y_gEO6wEeCjNNLZCc6mew", - "enum": [ - "LOF", - "AIS", - "LOM" - ], - "is-read-only": false, - "description": [ - "The valid list of problems for the entity." - ], - "uml-name": "_6Y_gEO6wEeCjNNLZCc6mew" - }, - "x-hnwmo6-x-ee-cj-nnlz-cc6-mew": { - "id": "x-hnwmo6-x-ee-cj-nnlz-cc6-mew", - "uml-id": "_xHNWMO6xEeCjNNLZCc6mew", - "enum": [ - "TIM", - "DEG", - "BDI", - "SSF" - ], - "is-read-only": false, - "description": [ - "The valid list of problems for the entity." - ], - "uml-name": "_xHNWMO6xEeCjNNLZCc6mew" - }, - "krq3-mk8-k-ee-g-z-yhf-u3-o-m-yg": { - "id": "krq3-mk8-k-ee-g-z-yhf-u3-o-m-yg", - "uml-id": "_KRQ3MK8KEeG_zYhfU3oMYg", - "enum": [ - "SINK", - "SOURCE" - ], - "is-read-only": false, - "description": [ - "The enumeration with the options for directionality for nonintrusive monitoring." - ], - "uml-name": "_KRQ3MK8KEeG_zYhfU3oMYg" - }, - "q-bme4-lu-y-ee-geq-z-lpdv-u3-ba": { - "id": "q-bme4-lu-y-ee-geq-z-lpdv-u3-ba", - "uml-id": "_qBme4LuYEeGeqZLpdvU3BA", - "enum": [ - "PERCENTAGE", - "NUMBER_ERRORED_BLOCKS" - ], - "is-read-only": false, - "description": [ - "

The value of the threshold can be provisioned in terms of number of errored blocks or in terms of percentage of errored blocks. For percentage-based specification, in order to support provision of less than 1%, the specification consists of two fields. The first field indicates the granularity of percentage. For examples, in 1%, in 0.1%, or in 0.01%, etc. The second field indicates the multiple of the granularity. For number of errored block based, the value is a positive integer.

" - ], - "uml-name": "_qBme4LuYEeGeqZLpdvU3BA" - }, - "parz8-nw-a-ee-gone-tb-gt8-x0-a": { - "id": "parz8-nw-a-ee-gone-tb-gt8-x0-a", - "uml-id": "_Parz8NwAEeGoneTbGt8X0A", - "enum": [ - "DWDM", - "CWDM", - "NO_WDM" - ], - "is-read-only": false, - "uml-name": "_Parz8NwAEeGoneTbGt8X0A" - }, - "v1-tu-a-nw-a-ee-gone-tb-gt8-x0-a": { - "id": "v1-tu-a-nw-a-ee-gone-tb-gt8-x0-a", - "uml-id": "_V1TuANwAEeGoneTbGt8X0A", - "enum": [ - "STANDARD", - "PROPRIETARY" - ], - "is-read-only": false, - "uml-name": "_V1TuANwAEeGoneTbGt8X0A" - }, - "yt7-s4-pzg-ee-g3-u-a-qk-ii-ctg": { - "id": "yt7-s4-pzg-ee-g3-u-a-qk-ii-ctg", - "uml-id": "_yt7S4PzgEeG3u-aQKIiCtg", - "enum": [ - "PATH", - "TCM1", - "TCM2", - "TCM3", - "TCM4", - "TCM5", - "TCM6", - "SECTION" - ], - "is-read-only": false, - "uml-name": "_yt7S4PzgEeG3u-aQKIiCtg" - }, - "lg3-y-qovv-ee-ky-u85-edu-w-r-a": { - "id": "lg3-y-qovv-ee-ky-u85-edu-w-r-a", - "uml-id": "_LG3yQOVVEeKyU85eduW_rA", - "enum": [ - "CONTROLLER", - "RESPONDER" - ], - "is-read-only": false, - "uml-name": "_LG3yQOVVEeKyU85eduW_rA" - }, - "7-fy9-s-jsc-ee-o-lx-kcui-ytz-cg": { - "id": "7-fy9-s-jsc-ee-o-lx-kcui-ytz-cg", - "uml-id": "_7fy9sJSCEeOLxKCUIYtzCg", - "enum": [ - "INCREASE_BW", - "DECREASE_BW" - ], - "is-read-only": false, - "uml-name": "_7fy9sJSCEeOLxKCUIYtzCg" - }, - "y6-wue-eam-eeab-npx3-o7-rjtw": { - "id": "y6-wue-eam-eeab-npx3-o7-rjtw", - "uml-id": "_Y6WUEEamEeabNPX3o7rjtw", - "enum": [ - "UNKNOWN", - "PERIOD_15MIN", - "PERIOD_24HOURS" - ], - "is-read-only": false, - "description": [ - "The enumeration with the options for granularity period of the performance data." - ], - "uml-name": "_Y6WUEEamEeabNPX3o7rjtw" - } - } -} \ No newline at end of file