X-Git-Url: https://gerrit.onap.org/r/gitweb?a=blobdiff_plain;f=boot%2Fvfc_vm_init.sh;h=f193b20df61ad5211c4da95302947999fa027c37;hb=d8bf64d1cd1be25e5cd4ca68aedf30897e7b8070;hp=24f85cfa8e584fbb0a4058dbe1f2442cadf05e5d;hpb=39b5b135d4e866ff4b4eefaf0b24298badb43b17;p=demo.git diff --git a/boot/vfc_vm_init.sh b/boot/vfc_vm_init.sh index 24f85cfa..f193b20d 100755 --- a/boot/vfc_vm_init.sh +++ b/boot/vfc_vm_init.sh @@ -4,32 +4,36 @@ NEXUS_USERNAME=$(cat /opt/config/nexus_username.txt) NEXUS_PASSWD=$(cat /opt/config/nexus_password.txt) NEXUS_DOCKER_REPO=$(cat /opt/config/nexus_docker_repo.txt) -DOCKER_IMAGE_VERSION=$(cat /opt/config/vfc_docker.txt) source /opt/config/onap_ips.txt +source /opt/config/vfc_docker.txt # Refresh images docker login -u $NEXUS_USERNAME -p $NEXUS_PASSWD $NEXUS_DOCKER_REPO -docker pull $NEXUS_DOCKER_REPO/onap/vfc/wfengine-activiti:$DOCKER_IMAGE_VERSION -docker pull $NEXUS_DOCKER_REPO/onap/vfc/wfengine-mgrservice:$DOCKER_IMAGE_VERSION -docker pull $NEXUS_DOCKER_REPO/onap/vfc/catalog:$DOCKER_IMAGE_VERSION -docker pull $NEXUS_DOCKER_REPO/onap/vfc/emsdriver:$DOCKER_IMAGE_VERSION -docker pull $NEXUS_DOCKER_REPO/onap/vfc/gvnfmdriver:$DOCKER_IMAGE_VERSION -docker pull $NEXUS_DOCKER_REPO/onap/vfc/jujudriver:$DOCKER_IMAGE_VERSION -docker pull $NEXUS_DOCKER_REPO/onap/vfc/nfvo/svnfm/huawei:$DOCKER_IMAGE_VERSION -docker pull $NEXUS_DOCKER_REPO/onap/vfc/nslcm:$DOCKER_IMAGE_VERSION -docker pull $NEXUS_DOCKER_REPO/onap/vfc/resmanagement:$DOCKER_IMAGE_VERSION -docker pull $NEXUS_DOCKER_REPO/onap/vfc/vnflcm:$DOCKER_IMAGE_VERSION -docker pull $NEXUS_DOCKER_REPO/onap/vfc/vnfmgr:$DOCKER_IMAGE_VERSION -docker pull $NEXUS_DOCKER_REPO/onap/vfc/vnfres:$DOCKER_IMAGE_VERSION -docker pull $NEXUS_DOCKER_REPO/onap/vfc/ztesdncdriver:$DOCKER_IMAGE_VERSION -docker pull $NEXUS_DOCKER_REPO/onap/vfc/ztevmanagerdriver:$DOCKER_IMAGE_VERSION -docker pull $NEXUS_DOCKER_REPO/onap/vfc/nfvo/svnfm/nokia:$DOCKER_IMAGE_VERSION +docker pull $NEXUS_DOCKER_REPO/onap/vfc/wfengine-activiti:$ACTIVITI_DOCKER_VER +docker pull $NEXUS_DOCKER_REPO/onap/vfc/wfengine-mgrservice:$MGRSERVICE_DOCKER_VER +docker pull $NEXUS_DOCKER_REPO/onap/vfc/catalog:$CATALOG_DOCKER_VER +docker pull $NEXUS_DOCKER_REPO/onap/vfc/multivimproxy:$MVIMPROXY_DOCKER_VER +docker pull $NEXUS_DOCKER_REPO/onap/vfc/emsdriver:$EMSDRIVER_DOCKER_VER +docker pull $NEXUS_DOCKER_REPO/onap/vfc/gvnfmdriver:$GVNFMDRIVER_DOCKER_VER +docker pull $NEXUS_DOCKER_REPO/onap/vfc/jujudriver:$JUJUDRIVER_DOCKER_VER +docker pull $NEXUS_DOCKER_REPO/onap/vfc/nfvo/svnfm/huawei:$HUAWEI_DOCKER_VER +docker pull $NEXUS_DOCKER_REPO/onap/vfc/nslcm:$NSLCM_DOCKER_VER +docker pull $NEXUS_DOCKER_REPO/onap/vfc/resmanagement:$RESMANAGEMENT_DOCKER_VER +docker pull $NEXUS_DOCKER_REPO/onap/vfc/vnflcm:$VNFLCM_DOCKER_VER +docker pull $NEXUS_DOCKER_REPO/onap/vfc/vnfmgr:$VNFMGR_DOCKER_VER +docker pull $NEXUS_DOCKER_REPO/onap/vfc/vnfres:$VNFRES_DOCKER_VER +docker pull $NEXUS_DOCKER_REPO/onap/vfc/ztesdncdriver:$ZTESDNCDRIVER_DOCKER_VER +docker pull $NEXUS_DOCKER_REPO/onap/vfc/ztevmanagerdriver:$ZTEVMANAGERDRIVER_DOCKER_VER +docker pull $NEXUS_DOCKER_REPO/onap/vfc/ztevnfmdriver:$ZTEVNFMDRIVER_DOCKER_VER +docker pull $NEXUS_DOCKER_REPO/onap/vfc/nfvo/svnfm/nokia:$NOKIA_DOCKER_VER +docker pull $NEXUS_DOCKER_REPO/onap/vfc/nfvo/svnfm/nokiav2:$NOKIAV2_DOCKER_VER docker rm -f vfc_wfengine_mgrservice docker rm -f vfc_wfengine_activiti docker rm -f vfc_catalog docker rm -f vfc_emsdriver +docker rm -f vfc_multivimproxy docker rm -f vfc_gvnfmdriver docker rm -f vfc_jujudriver docker rm -f vfc_svnfm_huawei @@ -40,21 +44,29 @@ docker rm -f vfc_vnfmgr docker rm -f vfc_vnfres docker rm -f vfc_ztesdncdriver docker rm -f vfc_ztevmanagerdriver +docker rm -f vfc_ztevnfmdriver docker rm -f vfc_svnfm_nokia +docker rm -f vfc_svnfm_nokiav2 # Insert docker run instructions here -docker run -i -t -d --name vfc_wfengine_activiti -p 8804:8080 -e SERVICE_IP=$OPENO_IP -e SERVICE_PORT=8804 -e OPENPALETTE_MSB_IP=$OPENO_IP -e OPENPALETTE_MSB_PORT=80 $NEXUS_DOCKER_REPO/onap/vfc/wfengine-activiti:$DOCKER_IMAGE_VERSION -docker run -i -t -d --name vfc_wfengine_mgrservice -p 8805:10550 -e SERVICE_IP=$OPENO_IP -e SERVICE_PORT=8805 -e OPENPALETTE_MSB_IP=$OPENO_IP -e OPENPALETTE_MSB_PORT=80 $NEXUS_DOCKER_REPO/onap/vfc/wfengine-mgrservice:$DOCKER_IMAGE_VERSION -docker run -i -t -d --name vfc_catalog -e MSB_ADDR=$OPENO_IP:80 $NEXUS_DOCKER_REPO/onap/vfc/catalog:$DOCKER_IMAGE_VERSION -docker run -i -t -d --name vfc_emsdriver -e MSB_ADDR=$OPENO_IP:80 $NEXUS_DOCKER_REPO/onap/vfc/emsdriver:$DOCKER_IMAGE_VERSION -docker run -i -t -d --name vfc_gvnfmdriver -e MSB_ADDR=$OPENO_IP:80 $NEXUS_DOCKER_REPO/onap/vfc/gvnfmdriver:$DOCKER_IMAGE_VERSION -docker run -i -t -d --name vfc_jujudriver -e MSB_ADDR=$OPENO_IP:80 $NEXUS_DOCKER_REPO/onap/vfc/jujudriver:$DOCKER_IMAGE_VERSION -docker run -i -t -d --name vfc_svnfm_huawei -e MSB_ADDR=$OPENO_IP:80 $NEXUS_DOCKER_REPO/onap/vfc/nfvo/svnfm/huawei:$DOCKER_IMAGE_VERSION -docker run -i -t -d --name vfc_nslcm -e MSB_ADDR=$OPENO_IP:80 $NEXUS_DOCKER_REPO/onap/vfc/nslcm:$DOCKER_IMAGE_VERSION -docker run -i -t -d --name vfc_resmanagement -e MSB_ADDR=$OPENO_IP:80 $NEXUS_DOCKER_REPO/onap/vfc/resmanagement:$DOCKER_IMAGE_VERSION -docker run -i -t -d --name vfc_vnflcm -e MSB_ADDR=$OPENO_IP:80 $NEXUS_DOCKER_REPO/onap/vfc/vnflcm:$DOCKER_IMAGE_VERSION -docker run -i -t -d --name vfc_vnfmgr -e MSB_ADDR=$OPENO_IP:80 $NEXUS_DOCKER_REPO/onap/vfc/vnfmgr:$DOCKER_IMAGE_VERSION -docker run -i -t -d --name vfc_vnfres -e MSB_ADDR=$OPENO_IP:80 $NEXUS_DOCKER_REPO/onap/vfc/vnfres:$DOCKER_IMAGE_VERSION -docker run -i -t -d --name vfc_ztesdncdriver -e MSB_ADDR=$OPENO_IP:80 $NEXUS_DOCKER_REPO/onap/vfc/ztesdncdriver:$DOCKER_IMAGE_VERSION -docker run -i -t -d --name vfc_ztevmanagerdriver -e MSB_ADDR=$OPENO_IP:80 $NEXUS_DOCKER_REPO/onap/vfc/ztevmanagerdriver:$DOCKER_IMAGE_VERSION -docker run -i -t -d --name vfc_svnfm_nokia -e MSB_ADDR=$OPENO_IP:80 $NEXUS_DOCKER_REPO/onap/vfc/nfvo/svnfm/nokia:$DOCKER_IMAGE_VERSION \ No newline at end of file +docker run -i -t -d --name vfc_wfengine_activiti -p 8804:8080 -e SERVICE_IP=$OPENO_IP -e SERVICE_PORT=8804 -e OPENPALETTE_MSB_IP=$OPENO_IP -e OPENPALETTE_MSB_PORT=80 $NEXUS_DOCKER_REPO/onap/vfc/wfengine-activiti:$ACTIVITI_DOCKER_VER +docker run -i -t -d --name vfc_wfengine_mgrservice -p 8805:10550 -e SERVICE_IP=$OPENO_IP -e SERVICE_PORT=8805 -e OPENPALETTE_MSB_IP=$OPENO_IP -e OPENPALETTE_MSB_PORT=80 $NEXUS_DOCKER_REPO/onap/vfc/wfengine-mgrservice:$MGRSERVICE_DOCKER_VER +docker run -i -t -d --name vfc_catalog -p 8806:8806 -e MSB_ADDR=$OPENO_IP:80 $NEXUS_DOCKER_REPO/onap/vfc/catalog:$CATALOG_DOCKER_VER +docker run -i -t -d --name vfc_emsdriver -p 8206:8206 -e MSB_ADDR=$OPENO_IP:80 -e VES_ADDR=$DCAE_COLL_IP:8080 -e VES_AUTHINFO="":"" $NEXUS_DOCKER_REPO/onap/vfc/emsdriver:$EMSDRIVER_DOCKER_VER +docker run -i -t -d --name vfc_gvnfmdriver -p 8484:8484 -e MSB_ADDR=$OPENO_IP:80 $NEXUS_DOCKER_REPO/onap/vfc/gvnfmdriver:$GVNFMDRIVER_DOCKER_VER +docker run -i -t -d --name vfc_jujudriver -p 8483:8483 -e MSB_ADDR=$OPENO_IP:80 $NEXUS_DOCKER_REPO/onap/vfc/jujudriver:$JUJUDRIVER_DOCKER_VER +docker run -i -t -d --name vfc_svnfm_huawei -p 8482:8482 -p 8443:8443 -e MSB_ADDR=$OPENO_IP:80 $NEXUS_DOCKER_REPO/onap/vfc/nfvo/svnfm/huawei:$HUAWEI_DOCKER_VER +docker run -i -t -d --name vfc_nslcm -p 8403:8403 -e MSB_ADDR=$OPENO_IP:80 $NEXUS_DOCKER_REPO/onap/vfc/nslcm:$NSLCM_DOCKER_VER +docker run -i -t -d --name vfc_resmanagement -p 8480:8480 -e MSB_ADDR=$OPENO_IP:80 $NEXUS_DOCKER_REPO/onap/vfc/resmanagement:$RESMANAGEMENT_DOCKER_VER +docker run -i -t -d --name vfc_vnflcm -p 8801:8801 -e MSB_ADDR=$OPENO_IP:80 $NEXUS_DOCKER_REPO/onap/vfc/vnflcm:$VNFLCM_DOCKER_VER +docker run -i -t -d --name vfc_vnfmgr -p 8803:8803 -e MSB_ADDR=$OPENO_IP:80 $NEXUS_DOCKER_REPO/onap/vfc/vnfmgr:$VNFMGR_DOCKER_VER +docker run -i -t -d --name vfc_vnfres -p 8802:8802 -e MSB_ADDR=$OPENO_IP:80 $NEXUS_DOCKER_REPO/onap/vfc/vnfres:$VNFRES_DOCKER_VER +docker run -i -t -d --name vfc_ztesdncdriver -p 8411:8411 -e MSB_ADDR=$OPENO_IP:80 $NEXUS_DOCKER_REPO/onap/vfc/ztesdncdriver:$ZTESDNCDRIVER_DOCKER_VER +docker run -i -t -d --name vfc_ztevnfmdriver -p 8410:8410 -e MSB_ADDR=$OPENO_IP:80 $NEXUS_DOCKER_REPO/onap/vfc/ztevnfmdriver:$ZTEVNFMDRIVER_DOCKER_VER +docker run -i -t -d --name vfc_svnfm_nokia -p 8486:8486 -e MSB_ADDR=$OPENO_IP:80 $NEXUS_DOCKER_REPO/onap/vfc/nfvo/svnfm/nokia:$NOKIA_DOCKER_VER + +CBAM_IP=$(cat /opt/config/cbam_ip.txt) +VNFM_ID=vnfmUuid +CBAM_PASSWORD=$(cat /opt/config/cbam_password.txt) +CBAM_USERNAME=$(cat /opt/config/cbam_username.txt) +docker run -i -t -d --name vfc_svnfm_nokiav2 -p 8089:8089 -e MSB_IP=$OPENO_IP -e CONFIGURE=kuku -e EXTERNAL_IP=$OPENO_IP -e "CBAM_CATALOG_URL=https://$CBAM_IP:443/api/catalog/adapter/" -e "CBAM_LCN_URL=https://$CBAM_IP:443/vnfm/lcn/v3/" -e "CBAM_KEYCLOAK_URL=https://$CBAM_IP:443/auth/" -e "CBAM_USERNAME=$CBAM_USERNAME" -e "CBAM_PASSWORD=$CBAM_PASSWORD" -e "VNFM_ID=$VNFM_ID" -d --stop-timeout 300 $NEXUS_DOCKER_REPO/onap/vfc/nfvo/svnfm/nokiav2:$NOKIAV2_DOCKER_VER