CSIT tests update for Synchronous VES collector
[integration/csit.git] / tests / dcaegen2 / testcases / assets / json_events / ves7_batch_with_different_domain.json
diff --git a/tests/dcaegen2/testcases/assets/json_events/ves7_batch_with_different_domain.json b/tests/dcaegen2/testcases/assets/json_events/ves7_batch_with_different_domain.json
new file mode 100644 (file)
index 0000000..0a7d4a0
--- /dev/null
@@ -0,0 +1,67 @@
+
+{
+   "eventList": [
+      {
+         "commonEventHeader": {
+            "version": "4.0.1",
+            "vesEventListenerVersion": "7.0.1",
+            "domain": "fault",
+            "eventName": "Fault_Vscf:Acs-Ericcson_PilotNumberPoolExhaustion",
+            "eventId": "fault0000250",
+            "sequence": 1,
+            "priority": "High",
+            "reportingEntityId": "cc305d54-75b4-431b-adb2-eb6b9e541234",
+            "reportingEntityName": "ibcx0001vm002oam0011234",
+            "sourceId": "de305d54-75b4-431b-adb2-eb6b9e546014",
+            "sourceName": "scfx0001vm002cap001",
+            "nfVendorName": "Ericsson",
+            "nfNamingCode": "scfx",
+            "nfcNamingCode": "ssc",
+            "startEpochMicrosec": 1413378172000000,
+            "lastEpochMicrosec": 1413378172000000,
+            "timeZoneOffset": "UTC-05:30"
+         },
+         "faultFields": {
+            "faultFieldsVersion": "4.0",
+            "alarmCondition": "PilotNumberPoolExhaustion",
+            "eventSourceType": "other",
+            "specificProblem": "Calls cannot complete - pilot numbers are unavailable",
+            "eventSeverity": "CRITICAL",
+            "vfStatus": "Active",
+            "alarmAdditionalInformation": {
+                "PilotNumberPoolSize": "1000"
+            }
+         }
+      },
+      {
+         "commonEventHeader": {
+            "version": "4.0.1",
+            "vesEventListenerVersion": "7.0.1",
+            "domain": "other",
+            "eventName": " Fault_Vscf:Acs-Ericcson_RecordingServerUnreachable",
+            "eventId": "other0000251",
+            "sequence": 0,
+            "priority": "High",
+            "reportingEntityId": "cc305d54-75b4-431b-adb2-eb6b9e541234",
+            "reportingEntityName": "ibcx0001vm002oam0011234",
+            "sourceId": "de305d54-75b4-431b-adb2-eb6b9e546014",
+            "sourceName": "scfx0001vm002cap001",
+            "nfVendorName": "Ericsson",
+            "nfNamingCode": "scfx",
+            "nfcNamingCode": "ssc",
+            "startEpochMicrosec": 1413378172000010,
+            "lastEpochMicrosec": 1413378172000010,
+            "timeZoneOffset": "UTC-05:30"
+         },
+         "faultFields": {
+            "faultFieldsVersion": "4.0",
+            "alarmCondition": "RecordingServerUnreachable",
+            "eventSourceType": "other",
+            "specificProblem": "Recording server unreachable",
+            "eventSeverity": "CRITICAL",
+            "vfStatus": "Active"
+         }
+      }
+   ]
+}
+