*** Settings ***
Documentation Integration tests for PRH.
... PRH receive events from DMaaP and produce or not PNF_READY notification depends on required fields in received event.
-Suite Setup Run keywords Create Headers AND Create sessions
+Suite Setup Run keywords Create Headers AND Create sessions AND Set default PRH config
Test Teardown Reset Simulators
Test Timeout 2 minutes
-Library resources/PrhLibrary.py
+Resource resources/prh_sessions.robot
Resource resources/prh_library.robot
-Resource ../../common.robot
+Resource resources/prh_config_library.robot
*** Variables ***
${TEST_CASES_DIR} %{WORKSPACE}/tests/dcaegen2/prh-testcases/assets
-${DMAAP_SIMULATOR_SETUP_URL} http://${DMAAP_SIMULATOR_SETUP}
-${AAI_SIMULATOR_SETUP_URL} http://${AAI_SIMULATOR_SETUP}
-${CONSUL_SETUP_URL} http://${CONSUL_SETUP}
-${PRH_SETUP_URL} http://${PRH_SETUP}
-${TRACE_LOG_LEVEL_CONF} {"configuredLevel":"TRACE","effectiveLevel":"TRACE"}
-${WARN_LOG_LEVEL_CONF} {"configuredLevel":"WARN","effectiveLevel":"WARN"}
-
*** Test Cases ***
BBS case event - attachment point
[Documentation] PRH get from DMaaP valid event with valid attachment point
[Tags] PRH Valid event
[Template] Verify PNF ready sent
${TEST_CASES_DIR}/ves-event-without-additional-fields
+ ${TEST_CASES_DIR}/ves-event-with-missing-IP-addresses
+ ${TEST_CASES_DIR}/ves-event-with-only-IP-addresses
${TEST_CASES_DIR}/ves-event-with-empty-additional-fields
${TEST_CASES_DIR}/ves-event-with-empty-attachment-point
-Should not sent PNF ready when DMaaP event is invalid
+Should not send PNF ready when DMaaP event has missing required field
[Documentation] PRH get from DMaaP event with missing required field
[Tags] PRH Invalid event
[Template] Verify event with missing required field is logged
${TEST_CASES_DIR}/ves-event-missing-field
-Should not sent PNF ready when DMaaP event is not JSON array
- [Documentation] Event from DMaaP is not JSON array
+Should not send PNF ready when DMaaP event is not JSON array
+ [Documentation] Event from DMaaP is not an array of JSON objects
[Tags] PRH Invalid event
- Verify incorrect JSON event is logged ${TEST_CASES_DIR}/ves-event-not-array
+ Verify incorrect JSON event is logged ${TEST_CASES_DIR}/ves-event-not-a-json-object
-Should not sent PNF ready when AAI record doesn't exist
+Should not send PNF ready when AAI record doesn't exist
[Documentation] PRH get from DMaaP valid event but given PNF doesn't exists in AAI
[Tags] PRH Missing AAI record
Verify missing AAI record is logged ${TEST_CASES_DIR}/aai-missing-entry
-Should not sent PNF ready when AAI is not responding
+Should not send PNF ready when AAI is not responding
[Documentation] PRH get from DMaaP valid event but AAI is not responding
[Tags] PRH AAI not responding
Verify AAI not responding is logged ${TEST_CASES_DIR}/aai-not-responding
+Should send PNF ready when logical link exists and replace it in AAI
+ [Documentation] PRH gets event from DMaaP with an attachment point, PNF is related to a logical link in AAI
+ [Tags] PRH Attachment point
+ [Template] Verify PNF ready sent and old logical link replaced in AAI
+ ${TEST_CASES_DIR}/pnf-with-existing-logical-link
+ ${TEST_CASES_DIR}/pnf-with-different-logical-link
+
BBS case event - Re-registration
- [Documentation] After regitered PNF, PRH reads another one PRH event with registration event
+ [Documentation] After registered PNF, PRH reads another one PRH event with registration event
[Tags] PRH Valid event Re registraiton
[Template] Verify PNF re registration
${TEST_CASES_DIR}/re-registration
+Should send PNF ready when the associated service instance is non-Active
+ [Documentation] PNF has a non active service instance, should send PNF_READY event
+ [Tags] PRH Service instance non active
+ [Template] Verify PNF ready sent when service instance non active
+ ${TEST_CASES_DIR}/service-instance-non-active
+
PRH logging level change
- [Documentation] PRH logging level change from WARN to TRACE
+ [Documentation] ad-hoc PRH logging level change using rest endpoint
[Tags] PRH logging level
- Verify change logging level
\ No newline at end of file
+ Verify change logging level