1 tosca_definitions_version: tosca_simple_yaml_1_0_0
3 template_name: GlobalSubstitutionTypes
5 - openecomp_heat_index:
6 file: openecomp-heat/_index.yml
8 org.openecomp.resource.abstract.nodes.heat.nested_pattern5:
9 derived_from: org.openecomp.resource.abstract.nodes.AbstractSubstitute
13 description: port network
18 description: Flavor for PD server
25 packet_external_network_name:
27 description: network name
30 packet_internal_network_name:
32 description: network name
37 description: PD server names
44 description: CMAUI1, CMAUI2 server names
51 description: availabilityzone name
56 description: sub interface network
61 description: PD Image server
69 - dependency_server_1b_pd_0:
70 capability: tosca.capabilities.Node
71 node: tosca.nodes.Root
72 relationship: tosca.relationships.DependsOn
76 - local_storage_server_1b_pd_0:
77 capability: tosca.capabilities.Attachment
78 node: tosca.nodes.BlockStorage
79 relationship: tosca.relationships.AttachesTo
83 - dependency_packet_external_network:
84 capability: tosca.capabilities.Node
85 node: tosca.nodes.Root
86 relationship: tosca.relationships.DependsOn
90 - dependency_pd_server_1b_port_0:
91 capability: tosca.capabilities.Node
92 node: tosca.nodes.Root
93 relationship: tosca.relationships.DependsOn
97 - dependency_test_resourceGroup_0:
98 capability: tosca.capabilities.Node
99 node: tosca.nodes.Root
100 relationship: tosca.relationships.DependsOn
104 - dependency_template_subint_Vlan_vmi_1_test_resourceGroup_0:
105 capability: tosca.capabilities.Node
106 node: tosca.nodes.Root
107 relationship: tosca.relationships.DependsOn
111 - dependency_packet_internal_network:
112 capability: tosca.capabilities.Node
113 node: tosca.nodes.Root
114 relationship: tosca.relationships.DependsOn
118 - dependency_test_nested_level2:
119 capability: tosca.capabilities.Node
120 node: tosca.nodes.Root
121 relationship: tosca.relationships.DependsOn
125 - dependency_server_1b_ps_1_test_nested_level2:
126 capability: tosca.capabilities.Node
127 node: tosca.nodes.Root
128 relationship: tosca.relationships.DependsOn
132 - local_storage_server_1b_ps_1_test_nested_level2:
133 capability: tosca.capabilities.Attachment
134 node: tosca.nodes.BlockStorage
135 relationship: tosca.relationships.AttachesTo
139 - dependency_test_resourceGroup_1_test_nested_level2:
140 capability: tosca.capabilities.Node
141 node: tosca.nodes.Root
142 relationship: tosca.relationships.DependsOn
146 - dependency_template_subint_Vlan_vmi_1_test_resourceGroup_1_test_nested_level2:
147 capability: tosca.capabilities.Node
148 node: tosca.nodes.Root
149 relationship: tosca.relationships.DependsOn
153 - dependency_test_resourceGroup_2_test_nested_level2:
154 capability: tosca.capabilities.Node
155 node: tosca.nodes.Root
156 relationship: tosca.relationships.DependsOn
160 - dependency_template_subint_Vlan_vmi_1_test_resourceGroup_2_test_nested_level2:
161 capability: tosca.capabilities.Node
162 node: tosca.nodes.Root
163 relationship: tosca.relationships.DependsOn
167 - dependency_ps_server_1b_port_1_test_nested_level2:
168 capability: tosca.capabilities.Node
169 node: tosca.nodes.Root
170 relationship: tosca.relationships.DependsOn
174 - dependency_ps_server_1b_1_port_1_test_nested_level2:
175 capability: tosca.capabilities.Node
176 node: tosca.nodes.Root
177 relationship: tosca.relationships.DependsOn
181 - dependency_packet_ext_network_test_nested_level2:
182 capability: tosca.capabilities.Node
183 node: tosca.nodes.Root
184 relationship: tosca.relationships.DependsOn
188 - dependency_packet_int_network_test_nested_level2:
189 capability: tosca.capabilities.Node
190 node: tosca.nodes.Root
191 relationship: tosca.relationships.DependsOn
195 - dependency_server_1b_ps_2_test_nested_level2:
196 capability: tosca.capabilities.Node
197 node: tosca.nodes.Root
198 relationship: tosca.relationships.DependsOn
202 - local_storage_server_1b_ps_2_test_nested_level2:
203 capability: tosca.capabilities.Attachment
204 node: tosca.nodes.BlockStorage
205 relationship: tosca.relationships.AttachesTo
210 disk.device.write.bytes.rate_server_1b_ps_1_test_nested_level2:
211 type: org.openecomp.capabilities.metric.Ceilometer
212 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
216 scalable_server_1b_ps_1_test_nested_level2:
217 type: tosca.capabilities.Scalable
221 network.outgoing.bytes.rate_ps_server_1b_1_port_1_test_nested_level2:
222 type: org.openecomp.capabilities.metric.Ceilometer
223 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
227 end_point_packet_ext_network_test_nested_level2:
228 type: tosca.capabilities.Endpoint
232 disk.capacity_server_1b_ps_2_test_nested_level2:
233 type: org.openecomp.capabilities.metric.Ceilometer
234 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
238 disk.device.latency_server_1b_ps_2_test_nested_level2:
239 type: org.openecomp.capabilities.metric.Ceilometer
240 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
244 disk.device.write.bytes_server_1b_ps_2_test_nested_level2:
245 type: org.openecomp.capabilities.metric.Ceilometer
246 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
250 disk.device.write.requests_server_1b_pd_0:
251 type: org.openecomp.capabilities.metric.Ceilometer
252 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
256 network.incoming.packets_ps_server_1b_1_port_1_test_nested_level2:
257 type: org.openecomp.capabilities.metric.Ceilometer
258 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
262 disk.read.requests_server_1b_ps_2_test_nested_level2:
263 type: org.openecomp.capabilities.metric.Ceilometer
264 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
268 endpoint_server_1b_ps_2_test_nested_level2:
269 type: tosca.capabilities.Endpoint.Admin
273 disk.iops_server_1b_ps_2_test_nested_level2:
274 type: org.openecomp.capabilities.metric.Ceilometer
275 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
279 disk.device.read.bytes_server_1b_ps_1_test_nested_level2:
280 type: org.openecomp.capabilities.metric.Ceilometer
281 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
285 feature_packet_ext_network_test_nested_level2:
286 type: tosca.capabilities.Node
290 forwarder_ps_server_1b_port_1_test_nested_level2:
291 type: org.openecomp.capabilities.Forwarder
295 forwarder_pd_server_1b_port_0:
296 type: org.openecomp.capabilities.Forwarder
300 disk.capacity_server_1b_pd_0:
301 type: org.openecomp.capabilities.metric.Ceilometer
302 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
306 forwarder_ps_server_1b_1_port_1_test_nested_level2:
307 type: org.openecomp.capabilities.Forwarder
311 network.outpoing.packets_pd_server_1b_port_0:
312 type: org.openecomp.capabilities.metric.Ceilometer
313 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
317 feature_ps_server_1b_1_port_1_test_nested_level2:
318 type: tosca.capabilities.Node
322 cpu_util_server_1b_ps_2_test_nested_level2:
323 type: org.openecomp.capabilities.metric.Ceilometer
324 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
328 network.incoming.packets_ps_server_1b_port_1_test_nested_level2:
329 type: org.openecomp.capabilities.metric.Ceilometer
330 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
334 network.outpoing.packets_ps_server_1b_1_port_1_test_nested_level2:
335 type: org.openecomp.capabilities.metric.Ceilometer
336 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
340 feature_pd_server_1b_port_0:
341 type: tosca.capabilities.Node
345 memory_server_1b_ps_1_test_nested_level2:
346 type: org.openecomp.capabilities.metric.Ceilometer
347 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
351 link_packet_int_network_test_nested_level2:
352 type: tosca.capabilities.network.Linkable
356 os_server_1b_ps_1_test_nested_level2:
357 type: tosca.capabilities.OperatingSystem
361 disk.root.size_server_1b_ps_1_test_nested_level2:
362 type: org.openecomp.capabilities.metric.Ceilometer
363 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
367 attachment_packet_internal_network:
368 type: tosca.capabilities.Attachment
372 disk.device.allocation_server_1b_pd_0:
373 type: org.openecomp.capabilities.metric.Ceilometer
374 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
378 feature_test_resourceGroup_0:
379 type: tosca.capabilities.Node
383 feature_packet_int_network_test_nested_level2:
384 type: tosca.capabilities.Node
388 disk.write.requests_server_1b_ps_1_test_nested_level2:
389 type: org.openecomp.capabilities.metric.Ceilometer
390 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
395 type: org.openecomp.capabilities.metric.Ceilometer
396 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
400 disk.write.requests.rate_server_1b_pd_0:
401 type: org.openecomp.capabilities.metric.Ceilometer
402 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
406 disk.latency_server_1b_ps_1_test_nested_level2:
407 type: org.openecomp.capabilities.metric.Ceilometer
408 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
412 feature_template_subint_Vlan_vmi_1_test_resourceGroup_1_test_nested_level2:
413 type: tosca.capabilities.Node
417 disk.device.read.bytes.rate_server_1b_pd_0:
418 type: org.openecomp.capabilities.metric.Ceilometer
419 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
423 feature_test_nested_level2:
424 type: tosca.capabilities.Node
428 disk.write.bytes.rate_server_1b_pd_0:
429 type: org.openecomp.capabilities.metric.Ceilometer
430 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
434 disk.device.usage_server_1b_ps_1_test_nested_level2:
435 type: org.openecomp.capabilities.metric.Ceilometer
436 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
440 disk.device.read.requests.rate_server_1b_ps_2_test_nested_level2:
441 type: org.openecomp.capabilities.metric.Ceilometer
442 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
446 disk.read.bytes_server_1b_ps_1_test_nested_level2:
447 type: org.openecomp.capabilities.metric.Ceilometer
448 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
452 disk.read.bytes_server_1b_ps_2_test_nested_level2:
453 type: org.openecomp.capabilities.metric.Ceilometer
454 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
458 cpu_server_1b_ps_1_test_nested_level2:
459 type: org.openecomp.capabilities.metric.Ceilometer
460 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
464 disk.usage_server_1b_pd_0:
465 type: org.openecomp.capabilities.metric.Ceilometer
466 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
470 disk.ephemeral.size_server_1b_ps_2_test_nested_level2:
471 type: org.openecomp.capabilities.metric.Ceilometer
472 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
476 end_point_packet_int_network_test_nested_level2:
477 type: tosca.capabilities.Endpoint
481 disk.device.iops_server_1b_pd_0:
482 type: org.openecomp.capabilities.metric.Ceilometer
483 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
487 disk.write.bytes.rate_server_1b_ps_1_test_nested_level2:
488 type: org.openecomp.capabilities.metric.Ceilometer
489 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
493 scalable_server_1b_ps_2_test_nested_level2:
494 type: tosca.capabilities.Scalable
498 cpu_util_server_1b_pd_0:
499 type: org.openecomp.capabilities.metric.Ceilometer
500 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
504 disk.read.requests_server_1b_pd_0:
505 type: org.openecomp.capabilities.metric.Ceilometer
506 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
510 network.outgoing.packets.rate_ps_server_1b_1_port_1_test_nested_level2:
511 type: org.openecomp.capabilities.metric.Ceilometer
512 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
516 disk.device.write.bytes.rate_server_1b_pd_0:
517 type: org.openecomp.capabilities.metric.Ceilometer
518 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
522 vcpus_server_1b_ps_1_test_nested_level2:
523 type: org.openecomp.capabilities.metric.Ceilometer
524 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
528 disk.device.write.bytes_server_1b_ps_1_test_nested_level2:
529 type: org.openecomp.capabilities.metric.Ceilometer
530 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
534 feature_server_1b_ps_2_test_nested_level2:
535 type: tosca.capabilities.Node
539 disk.iops_server_1b_ps_1_test_nested_level2:
540 type: org.openecomp.capabilities.metric.Ceilometer
541 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
545 disk.device.read.bytes_server_1b_ps_2_test_nested_level2:
546 type: org.openecomp.capabilities.metric.Ceilometer
547 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
551 feature_server_1b_pd_0:
552 type: tosca.capabilities.Node
556 disk.device.write.requests.rate_server_1b_ps_2_test_nested_level2:
557 type: org.openecomp.capabilities.metric.Ceilometer
558 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
562 disk.device.write.requests_server_1b_ps_2_test_nested_level2:
563 type: org.openecomp.capabilities.metric.Ceilometer
564 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
568 disk.capacity_server_1b_ps_1_test_nested_level2:
569 type: org.openecomp.capabilities.metric.Ceilometer
570 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
574 disk.allocation_server_1b_ps_1_test_nested_level2:
575 type: org.openecomp.capabilities.metric.Ceilometer
576 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
580 endpoint_server_1b_ps_1_test_nested_level2:
581 type: tosca.capabilities.Endpoint.Admin
585 disk.usage_server_1b_ps_1_test_nested_level2:
586 type: org.openecomp.capabilities.metric.Ceilometer
587 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
591 disk.device.write.bytes_server_1b_pd_0:
592 type: org.openecomp.capabilities.metric.Ceilometer
593 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
597 disk.iops_server_1b_pd_0:
598 type: org.openecomp.capabilities.metric.Ceilometer
599 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
603 end_point_packet_external_network:
604 type: tosca.capabilities.Endpoint
608 disk.write.bytes_server_1b_pd_0:
609 type: org.openecomp.capabilities.metric.Ceilometer
610 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
614 cpu.delta_server_1b_ps_2_test_nested_level2:
615 type: org.openecomp.capabilities.metric.Ceilometer
616 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
620 instance_server_1b_ps_2_test_nested_level2:
621 type: org.openecomp.capabilities.metric.Ceilometer
622 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
626 disk.device.capacity_server_1b_ps_2_test_nested_level2:
627 type: org.openecomp.capabilities.metric.Ceilometer
628 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
632 binding_server_1b_pd_0:
633 type: tosca.capabilities.network.Bindable
637 disk.device.read.requests_server_1b_ps_2_test_nested_level2:
638 type: org.openecomp.capabilities.metric.Ceilometer
639 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
643 binding_ps_server_1b_1_port_1_test_nested_level2:
644 type: tosca.capabilities.network.Bindable
646 - org.openecomp.resource.cp.nodes.heat.network.contrailV2.VLANSubInterface
647 - org.openecomp.resource.cp.nodes.heat.network.v2.contrailV2.VLANSubInterface
651 network.incoming.bytes_ps_server_1b_1_port_1_test_nested_level2:
652 type: org.openecomp.capabilities.metric.Ceilometer
653 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
657 disk.device.write.requests.rate_server_1b_pd_0:
658 type: org.openecomp.capabilities.metric.Ceilometer
659 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
663 disk.device.iops_server_1b_ps_2_test_nested_level2:
664 type: org.openecomp.capabilities.metric.Ceilometer
665 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
669 network.outgoing.bytes_pd_server_1b_port_0:
670 type: org.openecomp.capabilities.metric.Ceilometer
671 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
675 network.incoming.packets.rate_ps_server_1b_1_port_1_test_nested_level2:
676 type: org.openecomp.capabilities.metric.Ceilometer
677 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
681 disk.read.requests_server_1b_ps_1_test_nested_level2:
682 type: org.openecomp.capabilities.metric.Ceilometer
683 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
687 network.outgoing.bytes_ps_server_1b_1_port_1_test_nested_level2:
688 type: org.openecomp.capabilities.metric.Ceilometer
689 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
693 memory.usage_server_1b_ps_1_test_nested_level2:
694 type: org.openecomp.capabilities.metric.Ceilometer
695 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
699 link_packet_external_network:
700 type: tosca.capabilities.network.Linkable
704 memory.usage_server_1b_ps_2_test_nested_level2:
705 type: org.openecomp.capabilities.metric.Ceilometer
706 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
710 disk.device.iops_server_1b_ps_1_test_nested_level2:
711 type: org.openecomp.capabilities.metric.Ceilometer
712 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
716 memory.resident_server_1b_pd_0:
717 type: org.openecomp.capabilities.metric.Ceilometer
718 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
722 network.outgoing.packets.rate_pd_server_1b_port_0:
723 type: org.openecomp.capabilities.metric.Ceilometer
724 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
728 disk.device.read.bytes_server_1b_pd_0:
729 type: org.openecomp.capabilities.metric.Ceilometer
730 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
734 feature_server_1b_ps_1_test_nested_level2:
735 type: tosca.capabilities.Node
739 vcpus_server_1b_ps_2_test_nested_level2:
740 type: org.openecomp.capabilities.metric.Ceilometer
741 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
745 attachment_pd_server_1b_port_0:
746 type: tosca.capabilities.Attachment
750 attachment_packet_ext_network_test_nested_level2:
751 type: tosca.capabilities.Attachment
755 disk.device.write.requests.rate_server_1b_ps_1_test_nested_level2:
756 type: org.openecomp.capabilities.metric.Ceilometer
757 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
761 host_server_1b_ps_1_test_nested_level2:
762 type: tosca.capabilities.Container
764 - tosca.nodes.SoftwareComponent
768 disk.ephemeral.size_server_1b_pd_0:
769 type: org.openecomp.capabilities.metric.Ceilometer
770 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
774 network.outgoing.bytes_ps_server_1b_port_1_test_nested_level2:
775 type: org.openecomp.capabilities.metric.Ceilometer
776 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
780 disk.write.bytes_server_1b_ps_1_test_nested_level2:
781 type: org.openecomp.capabilities.metric.Ceilometer
782 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
786 end_point_packet_internal_network:
787 type: tosca.capabilities.Endpoint
791 attachment_ps_server_1b_port_1_test_nested_level2:
792 type: tosca.capabilities.Attachment
796 feature_ps_server_1b_port_1_test_nested_level2:
797 type: tosca.capabilities.Node
801 feature_packet_internal_network:
802 type: tosca.capabilities.Node
806 cpu.delta_server_1b_ps_1_test_nested_level2:
807 type: org.openecomp.capabilities.metric.Ceilometer
808 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
812 disk.device.write.requests_server_1b_ps_1_test_nested_level2:
813 type: org.openecomp.capabilities.metric.Ceilometer
814 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
818 disk.device.capacity_server_1b_ps_1_test_nested_level2:
819 type: org.openecomp.capabilities.metric.Ceilometer
820 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
824 disk.usage_server_1b_ps_2_test_nested_level2:
825 type: org.openecomp.capabilities.metric.Ceilometer
826 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
830 instance_server_1b_pd_0:
831 type: org.openecomp.capabilities.metric.Ceilometer
832 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
836 disk.device.capacity_server_1b_pd_0:
837 type: org.openecomp.capabilities.metric.Ceilometer
838 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
842 disk.root.size_server_1b_ps_2_test_nested_level2:
843 type: org.openecomp.capabilities.metric.Ceilometer
844 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
848 disk.device.read.bytes.rate_server_1b_ps_1_test_nested_level2:
849 type: org.openecomp.capabilities.metric.Ceilometer
850 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
854 instance_server_1b_ps_1_test_nested_level2:
855 type: org.openecomp.capabilities.metric.Ceilometer
856 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
860 network.outgoing.bytes.rate_ps_server_1b_port_1_test_nested_level2:
861 type: org.openecomp.capabilities.metric.Ceilometer
862 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
866 network.incoming.packets.rate_ps_server_1b_port_1_test_nested_level2:
867 type: org.openecomp.capabilities.metric.Ceilometer
868 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
872 feature_template_subint_Vlan_vmi_1_test_resourceGroup_0:
873 type: tosca.capabilities.Node
877 disk.device.read.requests_server_1b_ps_1_test_nested_level2:
878 type: org.openecomp.capabilities.metric.Ceilometer
879 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
883 network.outgoing.bytes.rate_pd_server_1b_port_0:
884 type: org.openecomp.capabilities.metric.Ceilometer
885 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
889 network.incoming.packets.rate_pd_server_1b_port_0:
890 type: org.openecomp.capabilities.metric.Ceilometer
891 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
896 type: tosca.capabilities.OperatingSystem
900 network.incoming.bytes_ps_server_1b_port_1_test_nested_level2:
901 type: org.openecomp.capabilities.metric.Ceilometer
902 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
906 endpoint_server_1b_pd_0:
907 type: tosca.capabilities.Endpoint.Admin
911 disk.read.bytes_server_1b_pd_0:
912 type: org.openecomp.capabilities.metric.Ceilometer
913 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
917 cpu_util_server_1b_ps_1_test_nested_level2:
918 type: org.openecomp.capabilities.metric.Ceilometer
919 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
923 disk.write.requests_server_1b_ps_2_test_nested_level2:
924 type: org.openecomp.capabilities.metric.Ceilometer
925 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
929 disk.latency_server_1b_ps_2_test_nested_level2:
930 type: org.openecomp.capabilities.metric.Ceilometer
931 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
935 binding_server_1b_ps_1_test_nested_level2:
936 type: tosca.capabilities.network.Bindable
940 disk.device.usage_server_1b_ps_2_test_nested_level2:
941 type: org.openecomp.capabilities.metric.Ceilometer
942 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
946 network.incoming.bytes.rate_ps_server_1b_port_1_test_nested_level2:
947 type: org.openecomp.capabilities.metric.Ceilometer
948 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
952 feature_template_subint_Vlan_vmi_1_test_resourceGroup_2_test_nested_level2:
953 type: tosca.capabilities.Node
957 binding_ps_server_1b_port_1_test_nested_level2:
958 type: tosca.capabilities.network.Bindable
960 - org.openecomp.resource.cp.nodes.heat.network.contrailV2.VLANSubInterface
961 - org.openecomp.resource.cp.nodes.heat.network.v2.contrailV2.VLANSubInterface
966 type: tosca.capabilities.Container
968 - tosca.nodes.SoftwareComponent
972 attachment_packet_int_network_test_nested_level2:
973 type: tosca.capabilities.Attachment
977 network.incoming.bytes_pd_server_1b_port_0:
978 type: org.openecomp.capabilities.metric.Ceilometer
979 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
983 disk.root.size_server_1b_pd_0:
984 type: org.openecomp.capabilities.metric.Ceilometer
985 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
989 disk.ephemeral.size_server_1b_ps_1_test_nested_level2:
990 type: org.openecomp.capabilities.metric.Ceilometer
991 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
995 disk.allocation_server_1b_ps_2_test_nested_level2:
996 type: org.openecomp.capabilities.metric.Ceilometer
997 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1001 memory_server_1b_pd_0:
1002 type: org.openecomp.capabilities.metric.Ceilometer
1003 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1007 disk.device.latency_server_1b_pd_0:
1008 type: org.openecomp.capabilities.metric.Ceilometer
1009 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1013 binding_server_1b_ps_2_test_nested_level2:
1014 type: tosca.capabilities.network.Bindable
1018 disk.device.read.requests.rate_server_1b_ps_1_test_nested_level2:
1019 type: org.openecomp.capabilities.metric.Ceilometer
1020 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1024 disk.device.usage_server_1b_pd_0:
1025 type: org.openecomp.capabilities.metric.Ceilometer
1026 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1030 network.incoming.bytes.rate_ps_server_1b_1_port_1_test_nested_level2:
1031 type: org.openecomp.capabilities.metric.Ceilometer
1032 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1036 cpu_server_1b_ps_2_test_nested_level2:
1037 type: org.openecomp.capabilities.metric.Ceilometer
1038 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1042 feature_packet_external_network:
1043 type: tosca.capabilities.Node
1047 memory.resident_server_1b_ps_2_test_nested_level2:
1048 type: org.openecomp.capabilities.metric.Ceilometer
1049 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1053 memory.resident_server_1b_ps_1_test_nested_level2:
1054 type: org.openecomp.capabilities.metric.Ceilometer
1055 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1059 disk.write.bytes.rate_server_1b_ps_2_test_nested_level2:
1060 type: org.openecomp.capabilities.metric.Ceilometer
1061 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1065 disk.device.write.bytes.rate_server_1b_ps_2_test_nested_level2:
1066 type: org.openecomp.capabilities.metric.Ceilometer
1067 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1071 network.outgoing.packets.rate_ps_server_1b_port_1_test_nested_level2:
1072 type: org.openecomp.capabilities.metric.Ceilometer
1073 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1077 disk.device.latency_server_1b_ps_1_test_nested_level2:
1078 type: org.openecomp.capabilities.metric.Ceilometer
1079 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1083 disk.allocation_server_1b_pd_0:
1084 type: org.openecomp.capabilities.metric.Ceilometer
1085 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1089 link_packet_ext_network_test_nested_level2:
1090 type: tosca.capabilities.network.Linkable
1094 disk.write.bytes_server_1b_ps_2_test_nested_level2:
1095 type: org.openecomp.capabilities.metric.Ceilometer
1096 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1100 binding_pd_server_1b_port_0:
1101 type: tosca.capabilities.network.Bindable
1103 - org.openecomp.resource.cp.nodes.heat.network.contrailV2.VLANSubInterface
1104 - org.openecomp.resource.cp.nodes.heat.network.v2.contrailV2.VLANSubInterface
1108 host_server_1b_ps_2_test_nested_level2:
1109 type: tosca.capabilities.Container
1111 - tosca.nodes.SoftwareComponent
1115 disk.device.read.requests.rate_server_1b_pd_0:
1116 type: org.openecomp.capabilities.metric.Ceilometer
1117 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1121 link_packet_internal_network:
1122 type: tosca.capabilities.network.Linkable
1126 disk.write.requests_server_1b_pd_0:
1127 type: org.openecomp.capabilities.metric.Ceilometer
1128 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1132 disk.device.allocation_server_1b_ps_1_test_nested_level2:
1133 type: org.openecomp.capabilities.metric.Ceilometer
1134 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1138 attachment_ps_server_1b_1_port_1_test_nested_level2:
1139 type: tosca.capabilities.Attachment
1143 disk.device.read.bytes.rate_server_1b_ps_2_test_nested_level2:
1144 type: org.openecomp.capabilities.metric.Ceilometer
1145 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1149 scalable_server_1b_pd_0:
1150 type: tosca.capabilities.Scalable
1154 memory_server_1b_ps_2_test_nested_level2:
1155 type: org.openecomp.capabilities.metric.Ceilometer
1156 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1160 os_server_1b_ps_2_test_nested_level2:
1161 type: tosca.capabilities.OperatingSystem
1165 cpu.delta_server_1b_pd_0:
1166 type: org.openecomp.capabilities.metric.Ceilometer
1167 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1171 disk.read.bytes.rate_server_1b_ps_1_test_nested_level2:
1172 type: org.openecomp.capabilities.metric.Ceilometer
1173 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1177 feature_test_resourceGroup_1_test_nested_level2:
1178 type: tosca.capabilities.Node
1182 feature_test_resourceGroup_2_test_nested_level2:
1183 type: tosca.capabilities.Node
1187 disk.read.bytes.rate_server_1b_ps_2_test_nested_level2:
1188 type: org.openecomp.capabilities.metric.Ceilometer
1189 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1193 disk.device.allocation_server_1b_ps_2_test_nested_level2:
1194 type: org.openecomp.capabilities.metric.Ceilometer
1195 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1199 vcpus_server_1b_pd_0:
1200 type: org.openecomp.capabilities.metric.Ceilometer
1201 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1205 disk.device.read.requests_server_1b_pd_0:
1206 type: org.openecomp.capabilities.metric.Ceilometer
1207 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1211 network.incoming.packets_pd_server_1b_port_0:
1212 type: org.openecomp.capabilities.metric.Ceilometer
1213 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1217 disk.read.bytes.rate_server_1b_pd_0:
1218 type: org.openecomp.capabilities.metric.Ceilometer
1219 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1223 memory.usage_server_1b_pd_0:
1224 type: org.openecomp.capabilities.metric.Ceilometer
1225 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1229 attachment_packet_external_network:
1230 type: tosca.capabilities.Attachment
1234 network.outpoing.packets_ps_server_1b_port_1_test_nested_level2:
1235 type: org.openecomp.capabilities.metric.Ceilometer
1236 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1240 disk.latency_server_1b_pd_0:
1241 type: org.openecomp.capabilities.metric.Ceilometer
1242 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1246 network.incoming.bytes.rate_pd_server_1b_port_0:
1247 type: org.openecomp.capabilities.metric.Ceilometer
1248 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1252 disk.write.requests.rate_server_1b_ps_2_test_nested_level2:
1253 type: org.openecomp.capabilities.metric.Ceilometer
1254 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1258 disk.write.requests.rate_server_1b_ps_1_test_nested_level2:
1259 type: org.openecomp.capabilities.metric.Ceilometer
1260 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1264 org.openecomp.resource.abstract.nodes.pd_server_1b:
1265 derived_from: org.openecomp.resource.abstract.nodes.VFC
1267 compute_pd_server_1b_name:
1273 subinterface_nested_vlan_service_template_filter_count:
1279 port_pd_server_1b_port_0_subnetpoolid:
1283 port_pd_server_1b_port_0_exCP_naming:
1284 type: org.openecomp.datatypes.Naming
1289 description: Index value of this substitution service template runtime instance
1294 - greater_or_equal: 0
1295 port_pd_server_1b_port_0_ip_requirements:
1300 type: org.openecomp.datatypes.network.IpRequirements
1301 port_pd_server_1b_port_0_network_role_tag:
1309 port_pd_server_1b_port_0_order:
1313 port_pd_server_1b_port_0_network:
1319 subinterface_nested_vlan_net1:
1325 port_pd_server_1b_port_0_vlan_requirements:
1330 type: org.openecomp.datatypes.network.VlanRequirements
1335 port_pd_server_1b_port_0_related_networks:
1340 type: org.openecomp.datatypes.network.RelatedNetworksAssignments
1341 subinterface_nested_vlan_parent_interface:
1347 port_pd_server_1b_port_0_replacement_policy:
1353 port_pd_server_1b_port_0_network_role:
1357 port_pd_server_1b_port_0_mac_requirements:
1358 type: org.openecomp.datatypes.network.MacRequirements
1361 compute_pd_server_1b_availability_zone:
1367 port_pd_server_1b_port_0_fixed_ips:
1372 type: org.openecomp.datatypes.heat.neutron.port.FixedIps
1374 - dependency_pd_server_1b_pd_server_1b_port_0_nested_vlan:
1375 capability: tosca.capabilities.Node
1376 node: tosca.nodes.Root
1377 relationship: tosca.relationships.DependsOn
1381 - dependency_template_subint_Vlan_vmi_1_pd_server_1b_pd_server_1b_port_0_nested_vlan:
1382 capability: tosca.capabilities.Node
1383 node: tosca.nodes.Root
1384 relationship: tosca.relationships.DependsOn
1388 - subinterface_link_template_subint_Vlan_vmi_1_pd_server_1b_pd_server_1b_port_0_nested_vlan:
1389 capability: tosca.capabilities.network.Linkable
1390 relationship: tosca.relationships.network.LinksTo
1394 - dependency_pd_server_1b:
1395 capability: tosca.capabilities.Node
1396 node: tosca.nodes.Root
1397 relationship: tosca.relationships.DependsOn
1401 - local_storage_pd_server_1b:
1402 capability: tosca.capabilities.Attachment
1403 node: tosca.nodes.BlockStorage
1404 relationship: tosca.relationships.AttachesTo
1408 - dependency_pd_server_1b_pd_server_1b_port_0:
1409 capability: tosca.capabilities.Node
1410 node: tosca.nodes.Root
1411 relationship: tosca.relationships.DependsOn
1415 - link_pd_server_1b_pd_server_1b_port_0:
1416 capability: tosca.capabilities.network.Linkable
1417 relationship: tosca.relationships.network.LinksTo
1422 disk.device.read.bytes_pd_server_1b:
1423 type: org.openecomp.capabilities.metric.Ceilometer
1424 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1429 type: tosca.capabilities.Container
1431 - tosca.nodes.SoftwareComponent
1435 disk.read.bytes.rate_pd_server_1b:
1436 type: org.openecomp.capabilities.metric.Ceilometer
1437 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1441 disk.allocation_pd_server_1b:
1442 type: org.openecomp.capabilities.metric.Ceilometer
1443 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1447 cpu.delta_pd_server_1b:
1448 type: org.openecomp.capabilities.metric.Ceilometer
1449 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1453 disk.device.read.requests_pd_server_1b:
1454 type: org.openecomp.capabilities.metric.Ceilometer
1455 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1459 network.incoming.packets.rate_pd_server_1b_pd_server_1b_port_0:
1460 type: org.openecomp.capabilities.metric.Ceilometer
1461 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1465 binding_pd_server_1b_pd_server_1b_port_0:
1466 type: tosca.capabilities.network.Bindable
1468 - org.openecomp.resource.cp.nodes.heat.network.contrailV2.VLANSubInterface
1469 - org.openecomp.resource.cp.nodes.heat.network.v2.contrailV2.VLANSubInterface
1473 feature_pd_server_1b:
1474 type: tosca.capabilities.Node
1478 disk.device.iops_pd_server_1b:
1479 type: org.openecomp.capabilities.metric.Ceilometer
1480 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1485 type: org.openecomp.capabilities.metric.Ceilometer
1486 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1490 disk.write.bytes.rate_pd_server_1b:
1491 type: org.openecomp.capabilities.metric.Ceilometer
1492 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1496 feature_template_subint_Vlan_vmi_1_pd_server_1b_pd_server_1b_port_0_nested_vlan:
1497 type: tosca.capabilities.Node
1501 disk.device.read.requests.rate_pd_server_1b:
1502 type: org.openecomp.capabilities.metric.Ceilometer
1503 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1507 endpoint_pd_server_1b:
1508 type: tosca.capabilities.Endpoint.Admin
1512 disk.device.allocation_pd_server_1b:
1513 type: org.openecomp.capabilities.metric.Ceilometer
1514 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1518 memory.usage_pd_server_1b:
1519 type: org.openecomp.capabilities.metric.Ceilometer
1520 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1524 network.incoming.bytes_pd_server_1b_pd_server_1b_port_0:
1525 type: org.openecomp.capabilities.metric.Ceilometer
1526 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1530 memory_pd_server_1b:
1531 type: org.openecomp.capabilities.metric.Ceilometer
1532 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1536 disk.device.read.bytes.rate_pd_server_1b:
1537 type: org.openecomp.capabilities.metric.Ceilometer
1538 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1542 disk.device.latency_pd_server_1b:
1543 type: org.openecomp.capabilities.metric.Ceilometer
1544 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1548 disk.read.bytes_pd_server_1b:
1549 type: org.openecomp.capabilities.metric.Ceilometer
1550 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1554 network.incoming.bytes.rate_pd_server_1b_pd_server_1b_port_0:
1555 type: org.openecomp.capabilities.metric.Ceilometer
1556 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1560 disk.device.usage_pd_server_1b:
1561 type: org.openecomp.capabilities.metric.Ceilometer
1562 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1566 disk.device.write.requests_pd_server_1b:
1567 type: org.openecomp.capabilities.metric.Ceilometer
1568 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1572 disk.latency_pd_server_1b:
1573 type: org.openecomp.capabilities.metric.Ceilometer
1574 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1578 feature_pd_server_1b_pd_server_1b_port_0_nested_vlan:
1579 type: tosca.capabilities.Node
1583 disk.ephemeral.size_pd_server_1b:
1584 type: org.openecomp.capabilities.metric.Ceilometer
1585 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1589 forwarder_pd_server_1b_pd_server_1b_port_0:
1590 type: org.openecomp.capabilities.Forwarder
1594 network.outgoing.bytes_pd_server_1b_pd_server_1b_port_0:
1595 type: org.openecomp.capabilities.metric.Ceilometer
1596 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1600 scalable_pd_server_1b:
1601 type: tosca.capabilities.Scalable
1605 disk.write.requests_pd_server_1b:
1606 type: org.openecomp.capabilities.metric.Ceilometer
1607 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1611 disk.device.write.bytes.rate_pd_server_1b:
1612 type: org.openecomp.capabilities.metric.Ceilometer
1613 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1617 disk.root.size_pd_server_1b:
1618 type: org.openecomp.capabilities.metric.Ceilometer
1619 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1623 network.outgoing.bytes.rate_pd_server_1b_pd_server_1b_port_0:
1624 type: org.openecomp.capabilities.metric.Ceilometer
1625 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1629 disk.iops_pd_server_1b:
1630 type: org.openecomp.capabilities.metric.Ceilometer
1631 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1635 feature_pd_server_1b_pd_server_1b_port_0:
1636 type: tosca.capabilities.Node
1640 disk.write.bytes_pd_server_1b:
1641 type: org.openecomp.capabilities.metric.Ceilometer
1642 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1646 disk.device.write.bytes_pd_server_1b:
1647 type: org.openecomp.capabilities.metric.Ceilometer
1648 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1653 type: tosca.capabilities.OperatingSystem
1658 type: org.openecomp.capabilities.metric.Ceilometer
1659 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1663 instance_pd_server_1b:
1664 type: org.openecomp.capabilities.metric.Ceilometer
1665 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1669 binding_pd_server_1b:
1670 type: tosca.capabilities.network.Bindable
1674 cpu_util_pd_server_1b:
1675 type: org.openecomp.capabilities.metric.Ceilometer
1676 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1680 network.outpoing.packets_pd_server_1b_pd_server_1b_port_0:
1681 type: org.openecomp.capabilities.metric.Ceilometer
1682 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1686 attachment_pd_server_1b_pd_server_1b_port_0:
1687 type: tosca.capabilities.Attachment
1691 memory.resident_pd_server_1b:
1692 type: org.openecomp.capabilities.metric.Ceilometer
1693 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1697 network.incoming.packets_pd_server_1b_pd_server_1b_port_0:
1698 type: org.openecomp.capabilities.metric.Ceilometer
1699 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1703 disk.device.write.requests.rate_pd_server_1b:
1704 type: org.openecomp.capabilities.metric.Ceilometer
1705 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1709 disk.device.capacity_pd_server_1b:
1710 type: org.openecomp.capabilities.metric.Ceilometer
1711 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1715 disk.read.requests_pd_server_1b:
1716 type: org.openecomp.capabilities.metric.Ceilometer
1717 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1721 disk.capacity_pd_server_1b:
1722 type: org.openecomp.capabilities.metric.Ceilometer
1723 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1727 disk.usage_pd_server_1b:
1728 type: org.openecomp.capabilities.metric.Ceilometer
1729 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1733 network.outgoing.packets.rate_pd_server_1b_pd_server_1b_port_0:
1734 type: org.openecomp.capabilities.metric.Ceilometer
1735 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1739 disk.write.requests.rate_pd_server_1b:
1740 type: org.openecomp.capabilities.metric.Ceilometer
1741 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1745 org.openecomp.resource.abstract.nodes.heat.nested_pattern5_levelTwo:
1746 derived_from: org.openecomp.resource.abstract.nodes.AbstractSubstitute
1750 description: port network
1761 packet_int_network_name:
1763 description: network name
1766 security_group_name:
1768 description: CMAUI1, CMAUI2 server names
1773 availability_zone_0:
1775 description: availabilityzone name
1778 ps_server_1b_flavor:
1780 description: Flavor for PS server
1785 description: Ps Image server
1790 description: sub interface network
1795 description: Ps server names
1800 packet_ext_network_name:
1802 description: network name
1806 - dependency_server_1b_ps_1:
1807 capability: tosca.capabilities.Node
1808 node: tosca.nodes.Root
1809 relationship: tosca.relationships.DependsOn
1813 - local_storage_server_1b_ps_1:
1814 capability: tosca.capabilities.Attachment
1815 node: tosca.nodes.BlockStorage
1816 relationship: tosca.relationships.AttachesTo
1820 - dependency_test_resourceGroup_1:
1821 capability: tosca.capabilities.Node
1822 node: tosca.nodes.Root
1823 relationship: tosca.relationships.DependsOn
1827 - dependency_template_subint_Vlan_vmi_1_test_resourceGroup_1:
1828 capability: tosca.capabilities.Node
1829 node: tosca.nodes.Root
1830 relationship: tosca.relationships.DependsOn
1834 - dependency_test_resourceGroup_2:
1835 capability: tosca.capabilities.Node
1836 node: tosca.nodes.Root
1837 relationship: tosca.relationships.DependsOn
1841 - dependency_template_subint_Vlan_vmi_1_test_resourceGroup_2:
1842 capability: tosca.capabilities.Node
1843 node: tosca.nodes.Root
1844 relationship: tosca.relationships.DependsOn
1848 - dependency_ps_server_1b_port_1:
1849 capability: tosca.capabilities.Node
1850 node: tosca.nodes.Root
1851 relationship: tosca.relationships.DependsOn
1855 - dependency_ps_server_1b_1_port_1:
1856 capability: tosca.capabilities.Node
1857 node: tosca.nodes.Root
1858 relationship: tosca.relationships.DependsOn
1862 - dependency_packet_ext_network:
1863 capability: tosca.capabilities.Node
1864 node: tosca.nodes.Root
1865 relationship: tosca.relationships.DependsOn
1869 - dependency_packet_int_network:
1870 capability: tosca.capabilities.Node
1871 node: tosca.nodes.Root
1872 relationship: tosca.relationships.DependsOn
1876 - dependency_server_1b_ps_2:
1877 capability: tosca.capabilities.Node
1878 node: tosca.nodes.Root
1879 relationship: tosca.relationships.DependsOn
1883 - local_storage_server_1b_ps_2:
1884 capability: tosca.capabilities.Attachment
1885 node: tosca.nodes.BlockStorage
1886 relationship: tosca.relationships.AttachesTo
1891 disk.device.latency_server_1b_ps_1:
1892 type: org.openecomp.capabilities.metric.Ceilometer
1893 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1897 disk.device.usage_server_1b_ps_1:
1898 type: org.openecomp.capabilities.metric.Ceilometer
1899 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1903 disk.device.usage_server_1b_ps_2:
1904 type: org.openecomp.capabilities.metric.Ceilometer
1905 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1909 disk.read.requests_server_1b_ps_1:
1910 type: org.openecomp.capabilities.metric.Ceilometer
1911 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1915 disk.device.write.requests.rate_server_1b_ps_1:
1916 type: org.openecomp.capabilities.metric.Ceilometer
1917 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1921 disk.read.requests_server_1b_ps_2:
1922 type: org.openecomp.capabilities.metric.Ceilometer
1923 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1927 disk.device.write.requests.rate_server_1b_ps_2:
1928 type: org.openecomp.capabilities.metric.Ceilometer
1929 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1933 binding_ps_server_1b_port_1:
1934 type: tosca.capabilities.network.Bindable
1936 - org.openecomp.resource.cp.nodes.heat.network.contrailV2.VLANSubInterface
1937 - org.openecomp.resource.cp.nodes.heat.network.v2.contrailV2.VLANSubInterface
1941 disk.read.bytes_server_1b_ps_1:
1942 type: org.openecomp.capabilities.metric.Ceilometer
1943 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1947 disk.read.bytes_server_1b_ps_2:
1948 type: org.openecomp.capabilities.metric.Ceilometer
1949 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1953 disk.device.latency_server_1b_ps_2:
1954 type: org.openecomp.capabilities.metric.Ceilometer
1955 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1959 disk.root.size_server_1b_ps_1:
1960 type: org.openecomp.capabilities.metric.Ceilometer
1961 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1965 disk.root.size_server_1b_ps_2:
1966 type: org.openecomp.capabilities.metric.Ceilometer
1967 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1971 network.incoming.bytes.rate_ps_server_1b_port_1:
1972 type: org.openecomp.capabilities.metric.Ceilometer
1973 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1977 disk.device.read.requests.rate_server_1b_ps_1:
1978 type: org.openecomp.capabilities.metric.Ceilometer
1979 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1983 disk.device.read.requests.rate_server_1b_ps_2:
1984 type: org.openecomp.capabilities.metric.Ceilometer
1985 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1989 feature_test_resourceGroup_1:
1990 type: tosca.capabilities.Node
1994 network.incoming.bytes_ps_server_1b_port_1:
1995 type: org.openecomp.capabilities.metric.Ceilometer
1996 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2000 attachment_packet_int_network:
2001 type: tosca.capabilities.Attachment
2005 cpu.delta_server_1b_ps_2:
2006 type: org.openecomp.capabilities.metric.Ceilometer
2007 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2011 memory.resident_server_1b_ps_2:
2012 type: org.openecomp.capabilities.metric.Ceilometer
2013 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2017 cpu.delta_server_1b_ps_1:
2018 type: org.openecomp.capabilities.metric.Ceilometer
2019 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2023 memory.resident_server_1b_ps_1:
2024 type: org.openecomp.capabilities.metric.Ceilometer
2025 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2029 cpu_util_server_1b_ps_1:
2030 type: org.openecomp.capabilities.metric.Ceilometer
2031 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2035 disk.device.write.bytes.rate_server_1b_ps_2:
2036 type: org.openecomp.capabilities.metric.Ceilometer
2037 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2041 disk.device.write.bytes.rate_server_1b_ps_1:
2042 type: org.openecomp.capabilities.metric.Ceilometer
2043 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2047 cpu_util_server_1b_ps_2:
2048 type: org.openecomp.capabilities.metric.Ceilometer
2049 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2053 disk.ephemeral.size_server_1b_ps_1:
2054 type: org.openecomp.capabilities.metric.Ceilometer
2055 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2059 disk.ephemeral.size_server_1b_ps_2:
2060 type: org.openecomp.capabilities.metric.Ceilometer
2061 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2065 disk.capacity_server_1b_ps_2:
2066 type: org.openecomp.capabilities.metric.Ceilometer
2067 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2071 memory_server_1b_ps_1:
2072 type: org.openecomp.capabilities.metric.Ceilometer
2073 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2077 network.outgoing.packets.rate_ps_server_1b_port_1:
2078 type: org.openecomp.capabilities.metric.Ceilometer
2079 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2083 disk.capacity_server_1b_ps_1:
2084 type: org.openecomp.capabilities.metric.Ceilometer
2085 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2089 memory_server_1b_ps_2:
2090 type: org.openecomp.capabilities.metric.Ceilometer
2091 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2095 instance_server_1b_ps_1:
2096 type: org.openecomp.capabilities.metric.Ceilometer
2097 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2101 forwarder_ps_server_1b_port_1:
2102 type: org.openecomp.capabilities.Forwarder
2106 link_packet_int_network:
2107 type: tosca.capabilities.network.Linkable
2111 instance_server_1b_ps_2:
2112 type: org.openecomp.capabilities.metric.Ceilometer
2113 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2117 network.outgoing.packets.rate_ps_server_1b_1_port_1:
2118 type: org.openecomp.capabilities.metric.Ceilometer
2119 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2123 disk.device.capacity_server_1b_ps_1:
2124 type: org.openecomp.capabilities.metric.Ceilometer
2125 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2129 end_point_packet_ext_network:
2130 type: tosca.capabilities.Endpoint
2134 disk.device.capacity_server_1b_ps_2:
2135 type: org.openecomp.capabilities.metric.Ceilometer
2136 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2140 network.outgoing.bytes_ps_server_1b_1_port_1:
2141 type: org.openecomp.capabilities.metric.Ceilometer
2142 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2146 disk.device.iops_server_1b_ps_2:
2147 type: org.openecomp.capabilities.metric.Ceilometer
2148 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2152 disk.device.iops_server_1b_ps_1:
2153 type: org.openecomp.capabilities.metric.Ceilometer
2154 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2158 network.incoming.packets_ps_server_1b_port_1:
2159 type: org.openecomp.capabilities.metric.Ceilometer
2160 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2164 network.outgoing.bytes.rate_ps_server_1b_port_1:
2165 type: org.openecomp.capabilities.metric.Ceilometer
2166 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2170 network.outpoing.packets_ps_server_1b_port_1:
2171 type: org.openecomp.capabilities.metric.Ceilometer
2172 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2176 endpoint_server_1b_ps_1:
2177 type: tosca.capabilities.Endpoint.Admin
2181 network.incoming.packets.rate_ps_server_1b_1_port_1:
2182 type: org.openecomp.capabilities.metric.Ceilometer
2183 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2187 network.incoming.bytes.rate_ps_server_1b_1_port_1:
2188 type: org.openecomp.capabilities.metric.Ceilometer
2189 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2193 disk.device.allocation_server_1b_ps_1:
2194 type: org.openecomp.capabilities.metric.Ceilometer
2195 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2199 endpoint_server_1b_ps_2:
2200 type: tosca.capabilities.Endpoint.Admin
2204 disk.write.requests.rate_server_1b_ps_2:
2205 type: org.openecomp.capabilities.metric.Ceilometer
2206 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2210 disk.write.requests.rate_server_1b_ps_1:
2211 type: org.openecomp.capabilities.metric.Ceilometer
2212 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2216 host_server_1b_ps_2:
2217 type: tosca.capabilities.Container
2219 - tosca.nodes.SoftwareComponent
2223 host_server_1b_ps_1:
2224 type: tosca.capabilities.Container
2226 - tosca.nodes.SoftwareComponent
2230 attachment_ps_server_1b_1_port_1:
2231 type: tosca.capabilities.Attachment
2235 feature_packet_int_network:
2236 type: tosca.capabilities.Node
2240 disk.write.bytes.rate_server_1b_ps_1:
2241 type: org.openecomp.capabilities.metric.Ceilometer
2242 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2246 disk.write.bytes_server_1b_ps_2:
2247 type: org.openecomp.capabilities.metric.Ceilometer
2248 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2252 disk.device.write.bytes_server_1b_ps_2:
2253 type: org.openecomp.capabilities.metric.Ceilometer
2254 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2258 disk.device.write.bytes_server_1b_ps_1:
2259 type: org.openecomp.capabilities.metric.Ceilometer
2260 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2264 disk.write.bytes_server_1b_ps_1:
2265 type: org.openecomp.capabilities.metric.Ceilometer
2266 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2270 disk.write.bytes.rate_server_1b_ps_2:
2271 type: org.openecomp.capabilities.metric.Ceilometer
2272 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2276 disk.device.allocation_server_1b_ps_2:
2277 type: org.openecomp.capabilities.metric.Ceilometer
2278 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2282 scalable_server_1b_ps_1:
2283 type: tosca.capabilities.Scalable
2287 network.outpoing.packets_ps_server_1b_1_port_1:
2288 type: org.openecomp.capabilities.metric.Ceilometer
2289 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2293 scalable_server_1b_ps_2:
2294 type: tosca.capabilities.Scalable
2298 disk.allocation_server_1b_ps_2:
2299 type: org.openecomp.capabilities.metric.Ceilometer
2300 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2304 disk.allocation_server_1b_ps_1:
2305 type: org.openecomp.capabilities.metric.Ceilometer
2306 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2310 feature_server_1b_ps_2:
2311 type: tosca.capabilities.Node
2315 feature_server_1b_ps_1:
2316 type: tosca.capabilities.Node
2320 vcpus_server_1b_ps_1:
2321 type: org.openecomp.capabilities.metric.Ceilometer
2322 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2326 network.outgoing.bytes.rate_ps_server_1b_1_port_1:
2327 type: org.openecomp.capabilities.metric.Ceilometer
2328 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2332 vcpus_server_1b_ps_2:
2333 type: org.openecomp.capabilities.metric.Ceilometer
2334 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2338 feature_template_subint_Vlan_vmi_1_test_resourceGroup_2:
2339 type: tosca.capabilities.Node
2343 network.incoming.bytes_ps_server_1b_1_port_1:
2344 type: org.openecomp.capabilities.metric.Ceilometer
2345 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2349 feature_template_subint_Vlan_vmi_1_test_resourceGroup_1:
2350 type: tosca.capabilities.Node
2354 disk.read.bytes.rate_server_1b_ps_2:
2355 type: org.openecomp.capabilities.metric.Ceilometer
2356 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2360 disk.read.bytes.rate_server_1b_ps_1:
2361 type: org.openecomp.capabilities.metric.Ceilometer
2362 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2366 disk.iops_server_1b_ps_1:
2367 type: org.openecomp.capabilities.metric.Ceilometer
2368 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2372 memory.usage_server_1b_ps_2:
2373 type: org.openecomp.capabilities.metric.Ceilometer
2374 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2378 memory.usage_server_1b_ps_1:
2379 type: org.openecomp.capabilities.metric.Ceilometer
2380 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2384 disk.iops_server_1b_ps_2:
2385 type: org.openecomp.capabilities.metric.Ceilometer
2386 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2390 disk.write.requests_server_1b_ps_1:
2391 type: org.openecomp.capabilities.metric.Ceilometer
2392 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2396 disk.write.requests_server_1b_ps_2:
2397 type: org.openecomp.capabilities.metric.Ceilometer
2398 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2402 disk.latency_server_1b_ps_2:
2403 type: org.openecomp.capabilities.metric.Ceilometer
2404 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2408 disk.latency_server_1b_ps_1:
2409 type: org.openecomp.capabilities.metric.Ceilometer
2410 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2414 network.incoming.packets.rate_ps_server_1b_port_1:
2415 type: org.openecomp.capabilities.metric.Ceilometer
2416 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2420 binding_server_1b_ps_1:
2421 type: tosca.capabilities.network.Bindable
2425 link_packet_ext_network:
2426 type: tosca.capabilities.network.Linkable
2430 binding_server_1b_ps_2:
2431 type: tosca.capabilities.network.Bindable
2435 disk.device.write.requests_server_1b_ps_1:
2436 type: org.openecomp.capabilities.metric.Ceilometer
2437 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2441 disk.device.read.requests_server_1b_ps_2:
2442 type: org.openecomp.capabilities.metric.Ceilometer
2443 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2447 disk.device.write.requests_server_1b_ps_2:
2448 type: org.openecomp.capabilities.metric.Ceilometer
2449 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2453 disk.device.read.requests_server_1b_ps_1:
2454 type: org.openecomp.capabilities.metric.Ceilometer
2455 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2459 end_point_packet_int_network:
2460 type: tosca.capabilities.Endpoint
2464 attachment_ps_server_1b_port_1:
2465 type: tosca.capabilities.Attachment
2469 attachment_packet_ext_network:
2470 type: tosca.capabilities.Attachment
2474 network.incoming.packets_ps_server_1b_1_port_1:
2475 type: org.openecomp.capabilities.metric.Ceilometer
2476 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2481 type: tosca.capabilities.OperatingSystem
2486 type: tosca.capabilities.OperatingSystem
2490 binding_ps_server_1b_1_port_1:
2491 type: tosca.capabilities.network.Bindable
2493 - org.openecomp.resource.cp.nodes.heat.network.contrailV2.VLANSubInterface
2494 - org.openecomp.resource.cp.nodes.heat.network.v2.contrailV2.VLANSubInterface
2498 feature_test_resourceGroup_2:
2499 type: tosca.capabilities.Node
2503 network.outgoing.bytes_ps_server_1b_port_1:
2504 type: org.openecomp.capabilities.metric.Ceilometer
2505 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2509 feature_ps_server_1b_1_port_1:
2510 type: tosca.capabilities.Node
2514 disk.usage_server_1b_ps_2:
2515 type: org.openecomp.capabilities.metric.Ceilometer
2516 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2520 disk.usage_server_1b_ps_1:
2521 type: org.openecomp.capabilities.metric.Ceilometer
2522 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2526 forwarder_ps_server_1b_1_port_1:
2527 type: org.openecomp.capabilities.Forwarder
2531 disk.device.read.bytes_server_1b_ps_2:
2532 type: org.openecomp.capabilities.metric.Ceilometer
2533 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2537 disk.device.read.bytes_server_1b_ps_1:
2538 type: org.openecomp.capabilities.metric.Ceilometer
2539 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2544 type: org.openecomp.capabilities.metric.Ceilometer
2545 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2550 type: org.openecomp.capabilities.metric.Ceilometer
2551 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2555 feature_packet_ext_network:
2556 type: tosca.capabilities.Node
2560 feature_ps_server_1b_port_1:
2561 type: tosca.capabilities.Node
2565 disk.device.read.bytes.rate_server_1b_ps_1:
2566 type: org.openecomp.capabilities.metric.Ceilometer
2567 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2571 disk.device.read.bytes.rate_server_1b_ps_2:
2572 type: org.openecomp.capabilities.metric.Ceilometer
2573 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2577 org.openecomp.resource.abstract.nodes.ps_server_1b:
2578 derived_from: org.openecomp.resource.abstract.nodes.VFC
2580 port_ps_server_1b_port_1_network_role_tag:
2584 port_ps_server_1b_port_1_related_networks:
2589 type: org.openecomp.datatypes.network.RelatedNetworksAssignments
2590 subinterface_nested_vlan_service_template_filter_count:
2598 description: Index value of this substitution service template runtime instance
2603 - greater_or_equal: 0
2604 port_ps_server_1b_port_1_ip_requirements:
2609 type: org.openecomp.datatypes.network.IpRequirements
2614 port_ps_server_1b_port_1_mac_requirements:
2615 type: org.openecomp.datatypes.network.MacRequirements
2618 port_ps_server_1b_port_1_network_role:
2622 subinterface_nested_vlan_net1:
2632 port_ps_server_1b_port_1_replacement_policy:
2638 port_ps_server_1b_port_1_exCP_naming:
2639 type: org.openecomp.datatypes.Naming
2642 port_ps_server_1b_port_1_fixed_ips:
2647 type: org.openecomp.datatypes.heat.neutron.port.FixedIps
2648 subinterface_nested_vlan_parent_interface:
2654 port_ps_server_1b_port_1_order:
2658 port_ps_server_1b_port_1_subnetpoolid:
2662 port_ps_server_1b_port_1_network:
2668 compute_ps_server_1b_availability_zone:
2674 port_ps_server_1b_port_1_vlan_requirements:
2679 type: org.openecomp.datatypes.network.VlanRequirements
2680 compute_ps_server_1b_name:
2687 - dependency_ps_server_1b:
2688 capability: tosca.capabilities.Node
2689 node: tosca.nodes.Root
2690 relationship: tosca.relationships.DependsOn
2694 - local_storage_ps_server_1b:
2695 capability: tosca.capabilities.Attachment
2696 node: tosca.nodes.BlockStorage
2697 relationship: tosca.relationships.AttachesTo
2701 - dependency_ps_server_1b_ps_server_1b_port_1:
2702 capability: tosca.capabilities.Node
2703 node: tosca.nodes.Root
2704 relationship: tosca.relationships.DependsOn
2708 - link_ps_server_1b_ps_server_1b_port_1:
2709 capability: tosca.capabilities.network.Linkable
2710 relationship: tosca.relationships.network.LinksTo
2714 - dependency_ps_server_1b_ps_server_1b_port_1_nested_vlan:
2715 capability: tosca.capabilities.Node
2716 node: tosca.nodes.Root
2717 relationship: tosca.relationships.DependsOn
2721 - dependency_template_subint_Vlan_vmi_1_ps_server_1b_ps_server_1b_port_1_nested_vlan:
2722 capability: tosca.capabilities.Node
2723 node: tosca.nodes.Root
2724 relationship: tosca.relationships.DependsOn
2728 - subinterface_link_template_subint_Vlan_vmi_1_ps_server_1b_ps_server_1b_port_1_nested_vlan:
2729 capability: tosca.capabilities.network.Linkable
2730 relationship: tosca.relationships.network.LinksTo
2735 disk.write.bytes.rate_ps_server_1b:
2736 type: org.openecomp.capabilities.metric.Ceilometer
2737 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2741 disk.device.usage_ps_server_1b:
2742 type: org.openecomp.capabilities.metric.Ceilometer
2743 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2747 disk.device.allocation_ps_server_1b:
2748 type: org.openecomp.capabilities.metric.Ceilometer
2749 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2753 disk.device.write.requests_ps_server_1b:
2754 type: org.openecomp.capabilities.metric.Ceilometer
2755 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2759 cpu_util_ps_server_1b:
2760 type: org.openecomp.capabilities.metric.Ceilometer
2761 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2765 scalable_ps_server_1b:
2766 type: tosca.capabilities.Scalable
2770 network.outgoing.bytes_ps_server_1b_ps_server_1b_port_1:
2771 type: org.openecomp.capabilities.metric.Ceilometer
2772 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2776 disk.device.read.bytes.rate_ps_server_1b:
2777 type: org.openecomp.capabilities.metric.Ceilometer
2778 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2782 disk.device.latency_ps_server_1b:
2783 type: org.openecomp.capabilities.metric.Ceilometer
2784 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2788 network.outgoing.packets.rate_ps_server_1b_ps_server_1b_port_1:
2789 type: org.openecomp.capabilities.metric.Ceilometer
2790 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2794 disk.device.iops_ps_server_1b:
2795 type: org.openecomp.capabilities.metric.Ceilometer
2796 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2800 disk.device.capacity_ps_server_1b:
2801 type: org.openecomp.capabilities.metric.Ceilometer
2802 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2806 instance_ps_server_1b:
2807 type: org.openecomp.capabilities.metric.Ceilometer
2808 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2813 type: org.openecomp.capabilities.metric.Ceilometer
2814 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2818 disk.device.write.bytes_ps_server_1b:
2819 type: org.openecomp.capabilities.metric.Ceilometer
2820 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2824 disk.read.bytes.rate_ps_server_1b:
2825 type: org.openecomp.capabilities.metric.Ceilometer
2826 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2830 disk.device.read.requests_ps_server_1b:
2831 type: org.openecomp.capabilities.metric.Ceilometer
2832 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2837 type: tosca.capabilities.Container
2839 - tosca.nodes.SoftwareComponent
2843 disk.usage_ps_server_1b:
2844 type: org.openecomp.capabilities.metric.Ceilometer
2845 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2849 disk.read.requests_ps_server_1b:
2850 type: org.openecomp.capabilities.metric.Ceilometer
2851 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2855 disk.device.read.requests.rate_ps_server_1b:
2856 type: org.openecomp.capabilities.metric.Ceilometer
2857 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2861 disk.capacity_ps_server_1b:
2862 type: org.openecomp.capabilities.metric.Ceilometer
2863 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2867 network.incoming.bytes_ps_server_1b_ps_server_1b_port_1:
2868 type: org.openecomp.capabilities.metric.Ceilometer
2869 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2873 disk.write.requests.rate_ps_server_1b:
2874 type: org.openecomp.capabilities.metric.Ceilometer
2875 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2879 disk.device.read.bytes_ps_server_1b:
2880 type: org.openecomp.capabilities.metric.Ceilometer
2881 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2885 attachment_ps_server_1b_ps_server_1b_port_1:
2886 type: tosca.capabilities.Attachment
2890 disk.device.write.requests.rate_ps_server_1b:
2891 type: org.openecomp.capabilities.metric.Ceilometer
2892 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2896 network.incoming.packets_ps_server_1b_ps_server_1b_port_1:
2897 type: org.openecomp.capabilities.metric.Ceilometer
2898 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2902 disk.root.size_ps_server_1b:
2903 type: org.openecomp.capabilities.metric.Ceilometer
2904 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2908 feature_ps_server_1b_ps_server_1b_port_1_nested_vlan:
2909 type: tosca.capabilities.Node
2913 binding_ps_server_1b:
2914 type: tosca.capabilities.network.Bindable
2918 memory.resident_ps_server_1b:
2919 type: org.openecomp.capabilities.metric.Ceilometer
2920 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2924 memory_ps_server_1b:
2925 type: org.openecomp.capabilities.metric.Ceilometer
2926 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2930 disk.write.bytes_ps_server_1b:
2931 type: org.openecomp.capabilities.metric.Ceilometer
2932 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2936 disk.device.write.bytes.rate_ps_server_1b:
2937 type: org.openecomp.capabilities.metric.Ceilometer
2938 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2942 disk.read.bytes_ps_server_1b:
2943 type: org.openecomp.capabilities.metric.Ceilometer
2944 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2948 network.outgoing.bytes.rate_ps_server_1b_ps_server_1b_port_1:
2949 type: org.openecomp.capabilities.metric.Ceilometer
2950 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2954 feature_ps_server_1b:
2955 type: tosca.capabilities.Node
2960 type: tosca.capabilities.OperatingSystem
2964 forwarder_ps_server_1b_ps_server_1b_port_1:
2965 type: org.openecomp.capabilities.Forwarder
2969 disk.iops_ps_server_1b:
2970 type: org.openecomp.capabilities.metric.Ceilometer
2971 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2975 disk.allocation_ps_server_1b:
2976 type: org.openecomp.capabilities.metric.Ceilometer
2977 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2981 disk.write.requests_ps_server_1b:
2982 type: org.openecomp.capabilities.metric.Ceilometer
2983 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2987 network.incoming.packets.rate_ps_server_1b_ps_server_1b_port_1:
2988 type: org.openecomp.capabilities.metric.Ceilometer
2989 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2993 binding_ps_server_1b_ps_server_1b_port_1:
2994 type: tosca.capabilities.network.Bindable
2996 - org.openecomp.resource.cp.nodes.heat.network.contrailV2.VLANSubInterface
2997 - org.openecomp.resource.cp.nodes.heat.network.v2.contrailV2.VLANSubInterface
3001 memory.usage_ps_server_1b:
3002 type: org.openecomp.capabilities.metric.Ceilometer
3003 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
3007 disk.latency_ps_server_1b:
3008 type: org.openecomp.capabilities.metric.Ceilometer
3009 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
3013 network.outpoing.packets_ps_server_1b_ps_server_1b_port_1:
3014 type: org.openecomp.capabilities.metric.Ceilometer
3015 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
3019 endpoint_ps_server_1b:
3020 type: tosca.capabilities.Endpoint.Admin
3024 feature_template_subint_Vlan_vmi_1_ps_server_1b_ps_server_1b_port_1_nested_vlan:
3025 type: tosca.capabilities.Node
3030 type: org.openecomp.capabilities.metric.Ceilometer
3031 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
3035 network.incoming.bytes.rate_ps_server_1b_ps_server_1b_port_1:
3036 type: org.openecomp.capabilities.metric.Ceilometer
3037 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
3041 cpu.delta_ps_server_1b:
3042 type: org.openecomp.capabilities.metric.Ceilometer
3043 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
3047 disk.ephemeral.size_ps_server_1b:
3048 type: org.openecomp.capabilities.metric.Ceilometer
3049 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
3053 feature_ps_server_1b_ps_server_1b_port_1:
3054 type: tosca.capabilities.Node
3058 org.openecomp.resource.abstract.nodes.heat.subinterface.nested_vlan:
3059 derived_from: org.openecomp.resource.abstract.nodes.AbstractSubstitute
3069 virtual_ipv6_address:
3077 lb_st_vlan_type_oam:
3090 subinterface_name_prefix:
3094 subinterface_instance_index:
3099 - dependency_template_subint_Vlan_vmi_1:
3100 capability: tosca.capabilities.Node
3101 node: tosca.nodes.Root
3102 relationship: tosca.relationships.DependsOn
3106 - subinterface_link_template_subint_Vlan_vmi_1:
3107 capability: tosca.capabilities.network.Linkable
3108 relationship: tosca.relationships.network.LinksTo
3112 - binding_template_subint_Vlan_vmi_1:
3113 capability: tosca.capabilities.network.Bindable
3114 node: org.openecomp.resource.cp.nodes.network.Port
3115 relationship: tosca.relationships.network.BindsTo
3120 feature_template_subint_Vlan_vmi_1:
3121 type: tosca.capabilities.Node