e44facaecf3611d0bcaa6dc538dc135e00e82dda
[sdc.git] /
1 tosca_definitions_version: tosca_simple_yaml_1_0_0
2 metadata:
3   template_name: GlobalSubstitutionTypes
4 imports:
5 - openecomp_heat_index:
6     file: openecomp-heat/_index.yml
7 node_types:
8   org.openecomp.resource.abstract.nodes.heat.nested_pattern5:
9     derived_from: org.openecomp.resource.abstract.nodes.AbstractSubstitute
10     properties:
11       port_net:
12         type: string
13         description: port network
14         required: true
15         status: SUPPORTED
16       pd_server_1b_flavor:
17         type: string
18         description: Flavor for PD server
19         required: true
20         status: SUPPORTED
21       pd_server_1b_ips:
22         type: string
23         required: true
24         status: SUPPORTED
25       packet_external_network_name:
26         type: string
27         description: network name
28         required: true
29         status: SUPPORTED
30       packet_internal_network_name:
31         type: string
32         description: network name
33         required: true
34         status: SUPPORTED
35       pd_server_1b_names:
36         type: list
37         description: PD server names
38         required: true
39         status: SUPPORTED
40         entry_schema:
41           type: string
42       security_group_name:
43         type: list
44         description: CMAUI1, CMAUI2 server names
45         required: true
46         status: SUPPORTED
47         entry_schema:
48           type: string
49       availability_zone_0:
50         type: string
51         description: availabilityzone name
52         required: true
53         status: SUPPORTED
54       sub_inf_net:
55         type: string
56         description: sub interface network
57         required: true
58         status: SUPPORTED
59       pd_server_1b_image:
60         type: string
61         description: PD Image server
62         required: true
63         status: SUPPORTED
64       pd_server_2b_ips:
65         type: string
66         required: true
67         status: SUPPORTED
68     requirements:
69     - dependency_server_1b_pd_0:
70         capability: tosca.capabilities.Node
71         node: tosca.nodes.Root
72         relationship: tosca.relationships.DependsOn
73         occurrences:
74         - 0
75         - UNBOUNDED
76     - local_storage_server_1b_pd_0:
77         capability: tosca.capabilities.Attachment
78         node: tosca.nodes.BlockStorage
79         relationship: tosca.relationships.AttachesTo
80         occurrences:
81         - 0
82         - UNBOUNDED
83     - dependency_packet_external_network:
84         capability: tosca.capabilities.Node
85         node: tosca.nodes.Root
86         relationship: tosca.relationships.DependsOn
87         occurrences:
88         - 0
89         - UNBOUNDED
90     - dependency_pd_server_1b_port_0:
91         capability: tosca.capabilities.Node
92         node: tosca.nodes.Root
93         relationship: tosca.relationships.DependsOn
94         occurrences:
95         - 0
96         - UNBOUNDED
97     - dependency_test_resourceGroup_0:
98         capability: tosca.capabilities.Node
99         node: tosca.nodes.Root
100         relationship: tosca.relationships.DependsOn
101         occurrences:
102         - 0
103         - UNBOUNDED
104     - dependency_template_subint_Vlan_vmi_1_test_resourceGroup_0:
105         capability: tosca.capabilities.Node
106         node: tosca.nodes.Root
107         relationship: tosca.relationships.DependsOn
108         occurrences:
109         - 0
110         - UNBOUNDED
111     - dependency_packet_internal_network:
112         capability: tosca.capabilities.Node
113         node: tosca.nodes.Root
114         relationship: tosca.relationships.DependsOn
115         occurrences:
116         - 0
117         - UNBOUNDED
118     - dependency_test_nested_level2:
119         capability: tosca.capabilities.Node
120         node: tosca.nodes.Root
121         relationship: tosca.relationships.DependsOn
122         occurrences:
123         - 0
124         - UNBOUNDED
125     - dependency_server_1b_ps_1_test_nested_level2:
126         capability: tosca.capabilities.Node
127         node: tosca.nodes.Root
128         relationship: tosca.relationships.DependsOn
129         occurrences:
130         - 0
131         - UNBOUNDED
132     - local_storage_server_1b_ps_1_test_nested_level2:
133         capability: tosca.capabilities.Attachment
134         node: tosca.nodes.BlockStorage
135         relationship: tosca.relationships.AttachesTo
136         occurrences:
137         - 0
138         - UNBOUNDED
139     - dependency_test_resourceGroup_1_test_nested_level2:
140         capability: tosca.capabilities.Node
141         node: tosca.nodes.Root
142         relationship: tosca.relationships.DependsOn
143         occurrences:
144         - 0
145         - UNBOUNDED
146     - dependency_template_subint_Vlan_vmi_1_test_resourceGroup_1_test_nested_level2:
147         capability: tosca.capabilities.Node
148         node: tosca.nodes.Root
149         relationship: tosca.relationships.DependsOn
150         occurrences:
151         - 0
152         - UNBOUNDED
153     - dependency_test_resourceGroup_2_test_nested_level2:
154         capability: tosca.capabilities.Node
155         node: tosca.nodes.Root
156         relationship: tosca.relationships.DependsOn
157         occurrences:
158         - 0
159         - UNBOUNDED
160     - dependency_template_subint_Vlan_vmi_1_test_resourceGroup_2_test_nested_level2:
161         capability: tosca.capabilities.Node
162         node: tosca.nodes.Root
163         relationship: tosca.relationships.DependsOn
164         occurrences:
165         - 0
166         - UNBOUNDED
167     - dependency_ps_server_1b_port_1_test_nested_level2:
168         capability: tosca.capabilities.Node
169         node: tosca.nodes.Root
170         relationship: tosca.relationships.DependsOn
171         occurrences:
172         - 0
173         - UNBOUNDED
174     - dependency_ps_server_1b_1_port_1_test_nested_level2:
175         capability: tosca.capabilities.Node
176         node: tosca.nodes.Root
177         relationship: tosca.relationships.DependsOn
178         occurrences:
179         - 0
180         - UNBOUNDED
181     - dependency_packet_ext_network_test_nested_level2:
182         capability: tosca.capabilities.Node
183         node: tosca.nodes.Root
184         relationship: tosca.relationships.DependsOn
185         occurrences:
186         - 0
187         - UNBOUNDED
188     - dependency_packet_int_network_test_nested_level2:
189         capability: tosca.capabilities.Node
190         node: tosca.nodes.Root
191         relationship: tosca.relationships.DependsOn
192         occurrences:
193         - 0
194         - UNBOUNDED
195     - dependency_server_1b_ps_2_test_nested_level2:
196         capability: tosca.capabilities.Node
197         node: tosca.nodes.Root
198         relationship: tosca.relationships.DependsOn
199         occurrences:
200         - 0
201         - UNBOUNDED
202     - local_storage_server_1b_ps_2_test_nested_level2:
203         capability: tosca.capabilities.Attachment
204         node: tosca.nodes.BlockStorage
205         relationship: tosca.relationships.AttachesTo
206         occurrences:
207         - 0
208         - UNBOUNDED
209     capabilities:
210       disk.device.write.bytes.rate_server_1b_ps_1_test_nested_level2:
211         type: org.openecomp.capabilities.metric.Ceilometer
212         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
213         occurrences:
214         - 1
215         - UNBOUNDED
216       scalable_server_1b_ps_1_test_nested_level2:
217         type: tosca.capabilities.Scalable
218         occurrences:
219         - 1
220         - UNBOUNDED
221       network.outgoing.bytes.rate_ps_server_1b_1_port_1_test_nested_level2:
222         type: org.openecomp.capabilities.metric.Ceilometer
223         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
224         occurrences:
225         - 1
226         - UNBOUNDED
227       end_point_packet_ext_network_test_nested_level2:
228         type: tosca.capabilities.Endpoint
229         occurrences:
230         - 1
231         - UNBOUNDED
232       disk.capacity_server_1b_ps_2_test_nested_level2:
233         type: org.openecomp.capabilities.metric.Ceilometer
234         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
235         occurrences:
236         - 1
237         - UNBOUNDED
238       disk.device.latency_server_1b_ps_2_test_nested_level2:
239         type: org.openecomp.capabilities.metric.Ceilometer
240         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
241         occurrences:
242         - 1
243         - UNBOUNDED
244       disk.device.write.bytes_server_1b_ps_2_test_nested_level2:
245         type: org.openecomp.capabilities.metric.Ceilometer
246         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
247         occurrences:
248         - 1
249         - UNBOUNDED
250       disk.device.write.requests_server_1b_pd_0:
251         type: org.openecomp.capabilities.metric.Ceilometer
252         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
253         occurrences:
254         - 1
255         - UNBOUNDED
256       network.incoming.packets_ps_server_1b_1_port_1_test_nested_level2:
257         type: org.openecomp.capabilities.metric.Ceilometer
258         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
259         occurrences:
260         - 1
261         - UNBOUNDED
262       disk.read.requests_server_1b_ps_2_test_nested_level2:
263         type: org.openecomp.capabilities.metric.Ceilometer
264         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
265         occurrences:
266         - 1
267         - UNBOUNDED
268       endpoint_server_1b_ps_2_test_nested_level2:
269         type: tosca.capabilities.Endpoint.Admin
270         occurrences:
271         - 1
272         - UNBOUNDED
273       disk.iops_server_1b_ps_2_test_nested_level2:
274         type: org.openecomp.capabilities.metric.Ceilometer
275         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
276         occurrences:
277         - 1
278         - UNBOUNDED
279       disk.device.read.bytes_server_1b_ps_1_test_nested_level2:
280         type: org.openecomp.capabilities.metric.Ceilometer
281         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
282         occurrences:
283         - 1
284         - UNBOUNDED
285       feature_packet_ext_network_test_nested_level2:
286         type: tosca.capabilities.Node
287         occurrences:
288         - 1
289         - UNBOUNDED
290       forwarder_ps_server_1b_port_1_test_nested_level2:
291         type: org.openecomp.capabilities.Forwarder
292         occurrences:
293         - 1
294         - UNBOUNDED
295       forwarder_pd_server_1b_port_0:
296         type: org.openecomp.capabilities.Forwarder
297         occurrences:
298         - 1
299         - UNBOUNDED
300       disk.capacity_server_1b_pd_0:
301         type: org.openecomp.capabilities.metric.Ceilometer
302         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
303         occurrences:
304         - 1
305         - UNBOUNDED
306       forwarder_ps_server_1b_1_port_1_test_nested_level2:
307         type: org.openecomp.capabilities.Forwarder
308         occurrences:
309         - 1
310         - UNBOUNDED
311       network.outpoing.packets_pd_server_1b_port_0:
312         type: org.openecomp.capabilities.metric.Ceilometer
313         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
314         occurrences:
315         - 1
316         - UNBOUNDED
317       feature_ps_server_1b_1_port_1_test_nested_level2:
318         type: tosca.capabilities.Node
319         occurrences:
320         - 1
321         - UNBOUNDED
322       cpu_util_server_1b_ps_2_test_nested_level2:
323         type: org.openecomp.capabilities.metric.Ceilometer
324         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
325         occurrences:
326         - 1
327         - UNBOUNDED
328       network.incoming.packets_ps_server_1b_port_1_test_nested_level2:
329         type: org.openecomp.capabilities.metric.Ceilometer
330         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
331         occurrences:
332         - 1
333         - UNBOUNDED
334       network.outpoing.packets_ps_server_1b_1_port_1_test_nested_level2:
335         type: org.openecomp.capabilities.metric.Ceilometer
336         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
337         occurrences:
338         - 1
339         - UNBOUNDED
340       feature_pd_server_1b_port_0:
341         type: tosca.capabilities.Node
342         occurrences:
343         - 1
344         - UNBOUNDED
345       memory_server_1b_ps_1_test_nested_level2:
346         type: org.openecomp.capabilities.metric.Ceilometer
347         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
348         occurrences:
349         - 1
350         - UNBOUNDED
351       link_packet_int_network_test_nested_level2:
352         type: tosca.capabilities.network.Linkable
353         occurrences:
354         - 1
355         - UNBOUNDED
356       os_server_1b_ps_1_test_nested_level2:
357         type: tosca.capabilities.OperatingSystem
358         occurrences:
359         - 1
360         - UNBOUNDED
361       disk.root.size_server_1b_ps_1_test_nested_level2:
362         type: org.openecomp.capabilities.metric.Ceilometer
363         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
364         occurrences:
365         - 1
366         - UNBOUNDED
367       attachment_packet_internal_network:
368         type: tosca.capabilities.Attachment
369         occurrences:
370         - 1
371         - UNBOUNDED
372       disk.device.allocation_server_1b_pd_0:
373         type: org.openecomp.capabilities.metric.Ceilometer
374         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
375         occurrences:
376         - 1
377         - UNBOUNDED
378       feature_test_resourceGroup_0:
379         type: tosca.capabilities.Node
380         occurrences:
381         - 1
382         - UNBOUNDED
383       feature_packet_int_network_test_nested_level2:
384         type: tosca.capabilities.Node
385         occurrences:
386         - 1
387         - UNBOUNDED
388       disk.write.requests_server_1b_ps_1_test_nested_level2:
389         type: org.openecomp.capabilities.metric.Ceilometer
390         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
391         occurrences:
392         - 1
393         - UNBOUNDED
394       cpu_server_1b_pd_0:
395         type: org.openecomp.capabilities.metric.Ceilometer
396         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
397         occurrences:
398         - 1
399         - UNBOUNDED
400       disk.write.requests.rate_server_1b_pd_0:
401         type: org.openecomp.capabilities.metric.Ceilometer
402         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
403         occurrences:
404         - 1
405         - UNBOUNDED
406       disk.latency_server_1b_ps_1_test_nested_level2:
407         type: org.openecomp.capabilities.metric.Ceilometer
408         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
409         occurrences:
410         - 1
411         - UNBOUNDED
412       feature_template_subint_Vlan_vmi_1_test_resourceGroup_1_test_nested_level2:
413         type: tosca.capabilities.Node
414         occurrences:
415         - 1
416         - UNBOUNDED
417       disk.device.read.bytes.rate_server_1b_pd_0:
418         type: org.openecomp.capabilities.metric.Ceilometer
419         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
420         occurrences:
421         - 1
422         - UNBOUNDED
423       feature_test_nested_level2:
424         type: tosca.capabilities.Node
425         occurrences:
426         - 1
427         - UNBOUNDED
428       disk.write.bytes.rate_server_1b_pd_0:
429         type: org.openecomp.capabilities.metric.Ceilometer
430         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
431         occurrences:
432         - 1
433         - UNBOUNDED
434       disk.device.usage_server_1b_ps_1_test_nested_level2:
435         type: org.openecomp.capabilities.metric.Ceilometer
436         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
437         occurrences:
438         - 1
439         - UNBOUNDED
440       disk.device.read.requests.rate_server_1b_ps_2_test_nested_level2:
441         type: org.openecomp.capabilities.metric.Ceilometer
442         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
443         occurrences:
444         - 1
445         - UNBOUNDED
446       disk.read.bytes_server_1b_ps_1_test_nested_level2:
447         type: org.openecomp.capabilities.metric.Ceilometer
448         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
449         occurrences:
450         - 1
451         - UNBOUNDED
452       disk.read.bytes_server_1b_ps_2_test_nested_level2:
453         type: org.openecomp.capabilities.metric.Ceilometer
454         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
455         occurrences:
456         - 1
457         - UNBOUNDED
458       cpu_server_1b_ps_1_test_nested_level2:
459         type: org.openecomp.capabilities.metric.Ceilometer
460         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
461         occurrences:
462         - 1
463         - UNBOUNDED
464       disk.usage_server_1b_pd_0:
465         type: org.openecomp.capabilities.metric.Ceilometer
466         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
467         occurrences:
468         - 1
469         - UNBOUNDED
470       disk.ephemeral.size_server_1b_ps_2_test_nested_level2:
471         type: org.openecomp.capabilities.metric.Ceilometer
472         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
473         occurrences:
474         - 1
475         - UNBOUNDED
476       end_point_packet_int_network_test_nested_level2:
477         type: tosca.capabilities.Endpoint
478         occurrences:
479         - 1
480         - UNBOUNDED
481       disk.device.iops_server_1b_pd_0:
482         type: org.openecomp.capabilities.metric.Ceilometer
483         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
484         occurrences:
485         - 1
486         - UNBOUNDED
487       disk.write.bytes.rate_server_1b_ps_1_test_nested_level2:
488         type: org.openecomp.capabilities.metric.Ceilometer
489         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
490         occurrences:
491         - 1
492         - UNBOUNDED
493       scalable_server_1b_ps_2_test_nested_level2:
494         type: tosca.capabilities.Scalable
495         occurrences:
496         - 1
497         - UNBOUNDED
498       cpu_util_server_1b_pd_0:
499         type: org.openecomp.capabilities.metric.Ceilometer
500         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
501         occurrences:
502         - 1
503         - UNBOUNDED
504       disk.read.requests_server_1b_pd_0:
505         type: org.openecomp.capabilities.metric.Ceilometer
506         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
507         occurrences:
508         - 1
509         - UNBOUNDED
510       network.outgoing.packets.rate_ps_server_1b_1_port_1_test_nested_level2:
511         type: org.openecomp.capabilities.metric.Ceilometer
512         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
513         occurrences:
514         - 1
515         - UNBOUNDED
516       disk.device.write.bytes.rate_server_1b_pd_0:
517         type: org.openecomp.capabilities.metric.Ceilometer
518         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
519         occurrences:
520         - 1
521         - UNBOUNDED
522       vcpus_server_1b_ps_1_test_nested_level2:
523         type: org.openecomp.capabilities.metric.Ceilometer
524         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
525         occurrences:
526         - 1
527         - UNBOUNDED
528       disk.device.write.bytes_server_1b_ps_1_test_nested_level2:
529         type: org.openecomp.capabilities.metric.Ceilometer
530         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
531         occurrences:
532         - 1
533         - UNBOUNDED
534       feature_server_1b_ps_2_test_nested_level2:
535         type: tosca.capabilities.Node
536         occurrences:
537         - 1
538         - UNBOUNDED
539       disk.iops_server_1b_ps_1_test_nested_level2:
540         type: org.openecomp.capabilities.metric.Ceilometer
541         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
542         occurrences:
543         - 1
544         - UNBOUNDED
545       disk.device.read.bytes_server_1b_ps_2_test_nested_level2:
546         type: org.openecomp.capabilities.metric.Ceilometer
547         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
548         occurrences:
549         - 1
550         - UNBOUNDED
551       feature_server_1b_pd_0:
552         type: tosca.capabilities.Node
553         occurrences:
554         - 1
555         - UNBOUNDED
556       disk.device.write.requests.rate_server_1b_ps_2_test_nested_level2:
557         type: org.openecomp.capabilities.metric.Ceilometer
558         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
559         occurrences:
560         - 1
561         - UNBOUNDED
562       disk.device.write.requests_server_1b_ps_2_test_nested_level2:
563         type: org.openecomp.capabilities.metric.Ceilometer
564         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
565         occurrences:
566         - 1
567         - UNBOUNDED
568       disk.capacity_server_1b_ps_1_test_nested_level2:
569         type: org.openecomp.capabilities.metric.Ceilometer
570         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
571         occurrences:
572         - 1
573         - UNBOUNDED
574       disk.allocation_server_1b_ps_1_test_nested_level2:
575         type: org.openecomp.capabilities.metric.Ceilometer
576         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
577         occurrences:
578         - 1
579         - UNBOUNDED
580       endpoint_server_1b_ps_1_test_nested_level2:
581         type: tosca.capabilities.Endpoint.Admin
582         occurrences:
583         - 1
584         - UNBOUNDED
585       disk.usage_server_1b_ps_1_test_nested_level2:
586         type: org.openecomp.capabilities.metric.Ceilometer
587         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
588         occurrences:
589         - 1
590         - UNBOUNDED
591       disk.device.write.bytes_server_1b_pd_0:
592         type: org.openecomp.capabilities.metric.Ceilometer
593         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
594         occurrences:
595         - 1
596         - UNBOUNDED
597       disk.iops_server_1b_pd_0:
598         type: org.openecomp.capabilities.metric.Ceilometer
599         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
600         occurrences:
601         - 1
602         - UNBOUNDED
603       end_point_packet_external_network:
604         type: tosca.capabilities.Endpoint
605         occurrences:
606         - 1
607         - UNBOUNDED
608       disk.write.bytes_server_1b_pd_0:
609         type: org.openecomp.capabilities.metric.Ceilometer
610         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
611         occurrences:
612         - 1
613         - UNBOUNDED
614       cpu.delta_server_1b_ps_2_test_nested_level2:
615         type: org.openecomp.capabilities.metric.Ceilometer
616         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
617         occurrences:
618         - 1
619         - UNBOUNDED
620       instance_server_1b_ps_2_test_nested_level2:
621         type: org.openecomp.capabilities.metric.Ceilometer
622         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
623         occurrences:
624         - 1
625         - UNBOUNDED
626       disk.device.capacity_server_1b_ps_2_test_nested_level2:
627         type: org.openecomp.capabilities.metric.Ceilometer
628         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
629         occurrences:
630         - 1
631         - UNBOUNDED
632       binding_server_1b_pd_0:
633         type: tosca.capabilities.network.Bindable
634         occurrences:
635         - 1
636         - UNBOUNDED
637       disk.device.read.requests_server_1b_ps_2_test_nested_level2:
638         type: org.openecomp.capabilities.metric.Ceilometer
639         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
640         occurrences:
641         - 1
642         - UNBOUNDED
643       binding_ps_server_1b_1_port_1_test_nested_level2:
644         type: tosca.capabilities.network.Bindable
645         valid_source_types:
646         - org.openecomp.resource.cp.nodes.heat.network.contrailV2.VLANSubInterface
647         - org.openecomp.resource.cp.nodes.heat.network.v2.contrailV2.VLANSubInterface
648         occurrences:
649         - 0
650         - UNBOUNDED
651       network.incoming.bytes_ps_server_1b_1_port_1_test_nested_level2:
652         type: org.openecomp.capabilities.metric.Ceilometer
653         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
654         occurrences:
655         - 1
656         - UNBOUNDED
657       disk.device.write.requests.rate_server_1b_pd_0:
658         type: org.openecomp.capabilities.metric.Ceilometer
659         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
660         occurrences:
661         - 1
662         - UNBOUNDED
663       disk.device.iops_server_1b_ps_2_test_nested_level2:
664         type: org.openecomp.capabilities.metric.Ceilometer
665         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
666         occurrences:
667         - 1
668         - UNBOUNDED
669       network.outgoing.bytes_pd_server_1b_port_0:
670         type: org.openecomp.capabilities.metric.Ceilometer
671         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
672         occurrences:
673         - 1
674         - UNBOUNDED
675       network.incoming.packets.rate_ps_server_1b_1_port_1_test_nested_level2:
676         type: org.openecomp.capabilities.metric.Ceilometer
677         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
678         occurrences:
679         - 1
680         - UNBOUNDED
681       disk.read.requests_server_1b_ps_1_test_nested_level2:
682         type: org.openecomp.capabilities.metric.Ceilometer
683         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
684         occurrences:
685         - 1
686         - UNBOUNDED
687       network.outgoing.bytes_ps_server_1b_1_port_1_test_nested_level2:
688         type: org.openecomp.capabilities.metric.Ceilometer
689         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
690         occurrences:
691         - 1
692         - UNBOUNDED
693       memory.usage_server_1b_ps_1_test_nested_level2:
694         type: org.openecomp.capabilities.metric.Ceilometer
695         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
696         occurrences:
697         - 1
698         - UNBOUNDED
699       link_packet_external_network:
700         type: tosca.capabilities.network.Linkable
701         occurrences:
702         - 1
703         - UNBOUNDED
704       memory.usage_server_1b_ps_2_test_nested_level2:
705         type: org.openecomp.capabilities.metric.Ceilometer
706         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
707         occurrences:
708         - 1
709         - UNBOUNDED
710       disk.device.iops_server_1b_ps_1_test_nested_level2:
711         type: org.openecomp.capabilities.metric.Ceilometer
712         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
713         occurrences:
714         - 1
715         - UNBOUNDED
716       memory.resident_server_1b_pd_0:
717         type: org.openecomp.capabilities.metric.Ceilometer
718         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
719         occurrences:
720         - 1
721         - UNBOUNDED
722       network.outgoing.packets.rate_pd_server_1b_port_0:
723         type: org.openecomp.capabilities.metric.Ceilometer
724         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
725         occurrences:
726         - 1
727         - UNBOUNDED
728       disk.device.read.bytes_server_1b_pd_0:
729         type: org.openecomp.capabilities.metric.Ceilometer
730         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
731         occurrences:
732         - 1
733         - UNBOUNDED
734       feature_server_1b_ps_1_test_nested_level2:
735         type: tosca.capabilities.Node
736         occurrences:
737         - 1
738         - UNBOUNDED
739       vcpus_server_1b_ps_2_test_nested_level2:
740         type: org.openecomp.capabilities.metric.Ceilometer
741         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
742         occurrences:
743         - 1
744         - UNBOUNDED
745       attachment_pd_server_1b_port_0:
746         type: tosca.capabilities.Attachment
747         occurrences:
748         - 1
749         - UNBOUNDED
750       attachment_packet_ext_network_test_nested_level2:
751         type: tosca.capabilities.Attachment
752         occurrences:
753         - 1
754         - UNBOUNDED
755       disk.device.write.requests.rate_server_1b_ps_1_test_nested_level2:
756         type: org.openecomp.capabilities.metric.Ceilometer
757         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
758         occurrences:
759         - 1
760         - UNBOUNDED
761       host_server_1b_ps_1_test_nested_level2:
762         type: tosca.capabilities.Container
763         valid_source_types:
764         - tosca.nodes.SoftwareComponent
765         occurrences:
766         - 1
767         - UNBOUNDED
768       disk.ephemeral.size_server_1b_pd_0:
769         type: org.openecomp.capabilities.metric.Ceilometer
770         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
771         occurrences:
772         - 1
773         - UNBOUNDED
774       network.outgoing.bytes_ps_server_1b_port_1_test_nested_level2:
775         type: org.openecomp.capabilities.metric.Ceilometer
776         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
777         occurrences:
778         - 1
779         - UNBOUNDED
780       disk.write.bytes_server_1b_ps_1_test_nested_level2:
781         type: org.openecomp.capabilities.metric.Ceilometer
782         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
783         occurrences:
784         - 1
785         - UNBOUNDED
786       end_point_packet_internal_network:
787         type: tosca.capabilities.Endpoint
788         occurrences:
789         - 1
790         - UNBOUNDED
791       attachment_ps_server_1b_port_1_test_nested_level2:
792         type: tosca.capabilities.Attachment
793         occurrences:
794         - 1
795         - UNBOUNDED
796       feature_ps_server_1b_port_1_test_nested_level2:
797         type: tosca.capabilities.Node
798         occurrences:
799         - 1
800         - UNBOUNDED
801       feature_packet_internal_network:
802         type: tosca.capabilities.Node
803         occurrences:
804         - 1
805         - UNBOUNDED
806       cpu.delta_server_1b_ps_1_test_nested_level2:
807         type: org.openecomp.capabilities.metric.Ceilometer
808         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
809         occurrences:
810         - 1
811         - UNBOUNDED
812       disk.device.write.requests_server_1b_ps_1_test_nested_level2:
813         type: org.openecomp.capabilities.metric.Ceilometer
814         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
815         occurrences:
816         - 1
817         - UNBOUNDED
818       disk.device.capacity_server_1b_ps_1_test_nested_level2:
819         type: org.openecomp.capabilities.metric.Ceilometer
820         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
821         occurrences:
822         - 1
823         - UNBOUNDED
824       disk.usage_server_1b_ps_2_test_nested_level2:
825         type: org.openecomp.capabilities.metric.Ceilometer
826         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
827         occurrences:
828         - 1
829         - UNBOUNDED
830       instance_server_1b_pd_0:
831         type: org.openecomp.capabilities.metric.Ceilometer
832         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
833         occurrences:
834         - 1
835         - UNBOUNDED
836       disk.device.capacity_server_1b_pd_0:
837         type: org.openecomp.capabilities.metric.Ceilometer
838         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
839         occurrences:
840         - 1
841         - UNBOUNDED
842       disk.root.size_server_1b_ps_2_test_nested_level2:
843         type: org.openecomp.capabilities.metric.Ceilometer
844         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
845         occurrences:
846         - 1
847         - UNBOUNDED
848       disk.device.read.bytes.rate_server_1b_ps_1_test_nested_level2:
849         type: org.openecomp.capabilities.metric.Ceilometer
850         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
851         occurrences:
852         - 1
853         - UNBOUNDED
854       instance_server_1b_ps_1_test_nested_level2:
855         type: org.openecomp.capabilities.metric.Ceilometer
856         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
857         occurrences:
858         - 1
859         - UNBOUNDED
860       network.outgoing.bytes.rate_ps_server_1b_port_1_test_nested_level2:
861         type: org.openecomp.capabilities.metric.Ceilometer
862         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
863         occurrences:
864         - 1
865         - UNBOUNDED
866       network.incoming.packets.rate_ps_server_1b_port_1_test_nested_level2:
867         type: org.openecomp.capabilities.metric.Ceilometer
868         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
869         occurrences:
870         - 1
871         - UNBOUNDED
872       feature_template_subint_Vlan_vmi_1_test_resourceGroup_0:
873         type: tosca.capabilities.Node
874         occurrences:
875         - 1
876         - UNBOUNDED
877       disk.device.read.requests_server_1b_ps_1_test_nested_level2:
878         type: org.openecomp.capabilities.metric.Ceilometer
879         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
880         occurrences:
881         - 1
882         - UNBOUNDED
883       network.outgoing.bytes.rate_pd_server_1b_port_0:
884         type: org.openecomp.capabilities.metric.Ceilometer
885         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
886         occurrences:
887         - 1
888         - UNBOUNDED
889       network.incoming.packets.rate_pd_server_1b_port_0:
890         type: org.openecomp.capabilities.metric.Ceilometer
891         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
892         occurrences:
893         - 1
894         - UNBOUNDED
895       os_server_1b_pd_0:
896         type: tosca.capabilities.OperatingSystem
897         occurrences:
898         - 1
899         - UNBOUNDED
900       network.incoming.bytes_ps_server_1b_port_1_test_nested_level2:
901         type: org.openecomp.capabilities.metric.Ceilometer
902         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
903         occurrences:
904         - 1
905         - UNBOUNDED
906       endpoint_server_1b_pd_0:
907         type: tosca.capabilities.Endpoint.Admin
908         occurrences:
909         - 1
910         - UNBOUNDED
911       disk.read.bytes_server_1b_pd_0:
912         type: org.openecomp.capabilities.metric.Ceilometer
913         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
914         occurrences:
915         - 1
916         - UNBOUNDED
917       cpu_util_server_1b_ps_1_test_nested_level2:
918         type: org.openecomp.capabilities.metric.Ceilometer
919         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
920         occurrences:
921         - 1
922         - UNBOUNDED
923       disk.write.requests_server_1b_ps_2_test_nested_level2:
924         type: org.openecomp.capabilities.metric.Ceilometer
925         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
926         occurrences:
927         - 1
928         - UNBOUNDED
929       disk.latency_server_1b_ps_2_test_nested_level2:
930         type: org.openecomp.capabilities.metric.Ceilometer
931         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
932         occurrences:
933         - 1
934         - UNBOUNDED
935       binding_server_1b_ps_1_test_nested_level2:
936         type: tosca.capabilities.network.Bindable
937         occurrences:
938         - 1
939         - UNBOUNDED
940       disk.device.usage_server_1b_ps_2_test_nested_level2:
941         type: org.openecomp.capabilities.metric.Ceilometer
942         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
943         occurrences:
944         - 1
945         - UNBOUNDED
946       network.incoming.bytes.rate_ps_server_1b_port_1_test_nested_level2:
947         type: org.openecomp.capabilities.metric.Ceilometer
948         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
949         occurrences:
950         - 1
951         - UNBOUNDED
952       feature_template_subint_Vlan_vmi_1_test_resourceGroup_2_test_nested_level2:
953         type: tosca.capabilities.Node
954         occurrences:
955         - 1
956         - UNBOUNDED
957       binding_ps_server_1b_port_1_test_nested_level2:
958         type: tosca.capabilities.network.Bindable
959         valid_source_types:
960         - org.openecomp.resource.cp.nodes.heat.network.contrailV2.VLANSubInterface
961         - org.openecomp.resource.cp.nodes.heat.network.v2.contrailV2.VLANSubInterface
962         occurrences:
963         - 0
964         - UNBOUNDED
965       host_server_1b_pd_0:
966         type: tosca.capabilities.Container
967         valid_source_types:
968         - tosca.nodes.SoftwareComponent
969         occurrences:
970         - 1
971         - UNBOUNDED
972       attachment_packet_int_network_test_nested_level2:
973         type: tosca.capabilities.Attachment
974         occurrences:
975         - 1
976         - UNBOUNDED
977       network.incoming.bytes_pd_server_1b_port_0:
978         type: org.openecomp.capabilities.metric.Ceilometer
979         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
980         occurrences:
981         - 1
982         - UNBOUNDED
983       disk.root.size_server_1b_pd_0:
984         type: org.openecomp.capabilities.metric.Ceilometer
985         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
986         occurrences:
987         - 1
988         - UNBOUNDED
989       disk.ephemeral.size_server_1b_ps_1_test_nested_level2:
990         type: org.openecomp.capabilities.metric.Ceilometer
991         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
992         occurrences:
993         - 1
994         - UNBOUNDED
995       disk.allocation_server_1b_ps_2_test_nested_level2:
996         type: org.openecomp.capabilities.metric.Ceilometer
997         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
998         occurrences:
999         - 1
1000         - UNBOUNDED
1001       memory_server_1b_pd_0:
1002         type: org.openecomp.capabilities.metric.Ceilometer
1003         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1004         occurrences:
1005         - 1
1006         - UNBOUNDED
1007       disk.device.latency_server_1b_pd_0:
1008         type: org.openecomp.capabilities.metric.Ceilometer
1009         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1010         occurrences:
1011         - 1
1012         - UNBOUNDED
1013       binding_server_1b_ps_2_test_nested_level2:
1014         type: tosca.capabilities.network.Bindable
1015         occurrences:
1016         - 1
1017         - UNBOUNDED
1018       disk.device.read.requests.rate_server_1b_ps_1_test_nested_level2:
1019         type: org.openecomp.capabilities.metric.Ceilometer
1020         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1021         occurrences:
1022         - 1
1023         - UNBOUNDED
1024       disk.device.usage_server_1b_pd_0:
1025         type: org.openecomp.capabilities.metric.Ceilometer
1026         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1027         occurrences:
1028         - 1
1029         - UNBOUNDED
1030       network.incoming.bytes.rate_ps_server_1b_1_port_1_test_nested_level2:
1031         type: org.openecomp.capabilities.metric.Ceilometer
1032         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1033         occurrences:
1034         - 1
1035         - UNBOUNDED
1036       cpu_server_1b_ps_2_test_nested_level2:
1037         type: org.openecomp.capabilities.metric.Ceilometer
1038         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1039         occurrences:
1040         - 1
1041         - UNBOUNDED
1042       feature_packet_external_network:
1043         type: tosca.capabilities.Node
1044         occurrences:
1045         - 1
1046         - UNBOUNDED
1047       memory.resident_server_1b_ps_2_test_nested_level2:
1048         type: org.openecomp.capabilities.metric.Ceilometer
1049         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1050         occurrences:
1051         - 1
1052         - UNBOUNDED
1053       memory.resident_server_1b_ps_1_test_nested_level2:
1054         type: org.openecomp.capabilities.metric.Ceilometer
1055         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1056         occurrences:
1057         - 1
1058         - UNBOUNDED
1059       disk.write.bytes.rate_server_1b_ps_2_test_nested_level2:
1060         type: org.openecomp.capabilities.metric.Ceilometer
1061         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1062         occurrences:
1063         - 1
1064         - UNBOUNDED
1065       disk.device.write.bytes.rate_server_1b_ps_2_test_nested_level2:
1066         type: org.openecomp.capabilities.metric.Ceilometer
1067         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1068         occurrences:
1069         - 1
1070         - UNBOUNDED
1071       network.outgoing.packets.rate_ps_server_1b_port_1_test_nested_level2:
1072         type: org.openecomp.capabilities.metric.Ceilometer
1073         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1074         occurrences:
1075         - 1
1076         - UNBOUNDED
1077       disk.device.latency_server_1b_ps_1_test_nested_level2:
1078         type: org.openecomp.capabilities.metric.Ceilometer
1079         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1080         occurrences:
1081         - 1
1082         - UNBOUNDED
1083       disk.allocation_server_1b_pd_0:
1084         type: org.openecomp.capabilities.metric.Ceilometer
1085         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1086         occurrences:
1087         - 1
1088         - UNBOUNDED
1089       link_packet_ext_network_test_nested_level2:
1090         type: tosca.capabilities.network.Linkable
1091         occurrences:
1092         - 1
1093         - UNBOUNDED
1094       disk.write.bytes_server_1b_ps_2_test_nested_level2:
1095         type: org.openecomp.capabilities.metric.Ceilometer
1096         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1097         occurrences:
1098         - 1
1099         - UNBOUNDED
1100       binding_pd_server_1b_port_0:
1101         type: tosca.capabilities.network.Bindable
1102         valid_source_types:
1103         - org.openecomp.resource.cp.nodes.heat.network.contrailV2.VLANSubInterface
1104         - org.openecomp.resource.cp.nodes.heat.network.v2.contrailV2.VLANSubInterface
1105         occurrences:
1106         - 0
1107         - UNBOUNDED
1108       host_server_1b_ps_2_test_nested_level2:
1109         type: tosca.capabilities.Container
1110         valid_source_types:
1111         - tosca.nodes.SoftwareComponent
1112         occurrences:
1113         - 1
1114         - UNBOUNDED
1115       disk.device.read.requests.rate_server_1b_pd_0:
1116         type: org.openecomp.capabilities.metric.Ceilometer
1117         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1118         occurrences:
1119         - 1
1120         - UNBOUNDED
1121       link_packet_internal_network:
1122         type: tosca.capabilities.network.Linkable
1123         occurrences:
1124         - 1
1125         - UNBOUNDED
1126       disk.write.requests_server_1b_pd_0:
1127         type: org.openecomp.capabilities.metric.Ceilometer
1128         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1129         occurrences:
1130         - 1
1131         - UNBOUNDED
1132       disk.device.allocation_server_1b_ps_1_test_nested_level2:
1133         type: org.openecomp.capabilities.metric.Ceilometer
1134         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1135         occurrences:
1136         - 1
1137         - UNBOUNDED
1138       attachment_ps_server_1b_1_port_1_test_nested_level2:
1139         type: tosca.capabilities.Attachment
1140         occurrences:
1141         - 1
1142         - UNBOUNDED
1143       disk.device.read.bytes.rate_server_1b_ps_2_test_nested_level2:
1144         type: org.openecomp.capabilities.metric.Ceilometer
1145         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1146         occurrences:
1147         - 1
1148         - UNBOUNDED
1149       scalable_server_1b_pd_0:
1150         type: tosca.capabilities.Scalable
1151         occurrences:
1152         - 1
1153         - UNBOUNDED
1154       memory_server_1b_ps_2_test_nested_level2:
1155         type: org.openecomp.capabilities.metric.Ceilometer
1156         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1157         occurrences:
1158         - 1
1159         - UNBOUNDED
1160       os_server_1b_ps_2_test_nested_level2:
1161         type: tosca.capabilities.OperatingSystem
1162         occurrences:
1163         - 1
1164         - UNBOUNDED
1165       cpu.delta_server_1b_pd_0:
1166         type: org.openecomp.capabilities.metric.Ceilometer
1167         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1168         occurrences:
1169         - 1
1170         - UNBOUNDED
1171       disk.read.bytes.rate_server_1b_ps_1_test_nested_level2:
1172         type: org.openecomp.capabilities.metric.Ceilometer
1173         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1174         occurrences:
1175         - 1
1176         - UNBOUNDED
1177       feature_test_resourceGroup_1_test_nested_level2:
1178         type: tosca.capabilities.Node
1179         occurrences:
1180         - 1
1181         - UNBOUNDED
1182       feature_test_resourceGroup_2_test_nested_level2:
1183         type: tosca.capabilities.Node
1184         occurrences:
1185         - 1
1186         - UNBOUNDED
1187       disk.read.bytes.rate_server_1b_ps_2_test_nested_level2:
1188         type: org.openecomp.capabilities.metric.Ceilometer
1189         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1190         occurrences:
1191         - 1
1192         - UNBOUNDED
1193       disk.device.allocation_server_1b_ps_2_test_nested_level2:
1194         type: org.openecomp.capabilities.metric.Ceilometer
1195         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1196         occurrences:
1197         - 1
1198         - UNBOUNDED
1199       vcpus_server_1b_pd_0:
1200         type: org.openecomp.capabilities.metric.Ceilometer
1201         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1202         occurrences:
1203         - 1
1204         - UNBOUNDED
1205       disk.device.read.requests_server_1b_pd_0:
1206         type: org.openecomp.capabilities.metric.Ceilometer
1207         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1208         occurrences:
1209         - 1
1210         - UNBOUNDED
1211       network.incoming.packets_pd_server_1b_port_0:
1212         type: org.openecomp.capabilities.metric.Ceilometer
1213         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1214         occurrences:
1215         - 1
1216         - UNBOUNDED
1217       disk.read.bytes.rate_server_1b_pd_0:
1218         type: org.openecomp.capabilities.metric.Ceilometer
1219         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1220         occurrences:
1221         - 1
1222         - UNBOUNDED
1223       memory.usage_server_1b_pd_0:
1224         type: org.openecomp.capabilities.metric.Ceilometer
1225         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1226         occurrences:
1227         - 1
1228         - UNBOUNDED
1229       attachment_packet_external_network:
1230         type: tosca.capabilities.Attachment
1231         occurrences:
1232         - 1
1233         - UNBOUNDED
1234       network.outpoing.packets_ps_server_1b_port_1_test_nested_level2:
1235         type: org.openecomp.capabilities.metric.Ceilometer
1236         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1237         occurrences:
1238         - 1
1239         - UNBOUNDED
1240       disk.latency_server_1b_pd_0:
1241         type: org.openecomp.capabilities.metric.Ceilometer
1242         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1243         occurrences:
1244         - 1
1245         - UNBOUNDED
1246       network.incoming.bytes.rate_pd_server_1b_port_0:
1247         type: org.openecomp.capabilities.metric.Ceilometer
1248         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1249         occurrences:
1250         - 1
1251         - UNBOUNDED
1252       disk.write.requests.rate_server_1b_ps_2_test_nested_level2:
1253         type: org.openecomp.capabilities.metric.Ceilometer
1254         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1255         occurrences:
1256         - 1
1257         - UNBOUNDED
1258       disk.write.requests.rate_server_1b_ps_1_test_nested_level2:
1259         type: org.openecomp.capabilities.metric.Ceilometer
1260         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1261         occurrences:
1262         - 1
1263         - UNBOUNDED
1264   org.openecomp.resource.abstract.nodes.pd_server_1b:
1265     derived_from: org.openecomp.resource.abstract.nodes.VFC
1266     properties:
1267       compute_pd_server_1b_name:
1268         type: list
1269         required: true
1270         status: SUPPORTED
1271         entry_schema:
1272           type: string
1273       subinterface_nested_vlan_service_template_filter_count:
1274         type: list
1275         required: true
1276         status: SUPPORTED
1277         entry_schema:
1278           type: float
1279       port_pd_server_1b_port_0_subnetpoolid:
1280         type: string
1281         required: true
1282         status: SUPPORTED
1283       port_pd_server_1b_port_0_exCP_naming:
1284         type: org.openecomp.datatypes.Naming
1285         required: true
1286         status: SUPPORTED
1287       index_value:
1288         type: integer
1289         description: Index value of this substitution service template runtime instance
1290         required: false
1291         default: 0
1292         status: SUPPORTED
1293         constraints:
1294         - greater_or_equal: 0
1295       port_pd_server_1b_port_0_ip_requirements:
1296         type: list
1297         required: true
1298         status: SUPPORTED
1299         entry_schema:
1300           type: org.openecomp.datatypes.network.IpRequirements
1301       port_pd_server_1b_port_0_network_role_tag:
1302         type: string
1303         required: true
1304         status: SUPPORTED
1305       vm_flavor_name:
1306         type: string
1307         required: true
1308         status: SUPPORTED
1309       port_pd_server_1b_port_0_order:
1310         type: integer
1311         required: true
1312         status: SUPPORTED
1313       port_pd_server_1b_port_0_network:
1314         type: list
1315         required: true
1316         status: SUPPORTED
1317         entry_schema:
1318           type: string
1319       subinterface_nested_vlan_net1:
1320         type: list
1321         required: true
1322         status: SUPPORTED
1323         entry_schema:
1324           type: string
1325       port_pd_server_1b_port_0_vlan_requirements:
1326         type: list
1327         required: true
1328         status: SUPPORTED
1329         entry_schema:
1330           type: org.openecomp.datatypes.network.VlanRequirements
1331       vm_image_name:
1332         type: string
1333         required: true
1334         status: SUPPORTED
1335       port_pd_server_1b_port_0_related_networks:
1336         type: list
1337         required: true
1338         status: SUPPORTED
1339         entry_schema:
1340           type: org.openecomp.datatypes.network.RelatedNetworksAssignments
1341       subinterface_nested_vlan_parent_interface:
1342         type: list
1343         required: true
1344         status: SUPPORTED
1345         entry_schema:
1346           type: string
1347       port_pd_server_1b_port_0_replacement_policy:
1348         type: list
1349         required: true
1350         status: SUPPORTED
1351         entry_schema:
1352           type: string
1353       port_pd_server_1b_port_0_network_role:
1354         type: string
1355         required: true
1356         status: SUPPORTED
1357       port_pd_server_1b_port_0_mac_requirements:
1358         type: org.openecomp.datatypes.network.MacRequirements
1359         required: true
1360         status: SUPPORTED
1361       compute_pd_server_1b_availability_zone:
1362         type: list
1363         required: true
1364         status: SUPPORTED
1365         entry_schema:
1366           type: string
1367       port_pd_server_1b_port_0_fixed_ips:
1368         type: list
1369         required: true
1370         status: SUPPORTED
1371         entry_schema:
1372           type: org.openecomp.datatypes.heat.neutron.port.FixedIps
1373     requirements:
1374     - dependency_pd_server_1b_pd_server_1b_port_0_nested_vlan:
1375         capability: tosca.capabilities.Node
1376         node: tosca.nodes.Root
1377         relationship: tosca.relationships.DependsOn
1378         occurrences:
1379         - 0
1380         - UNBOUNDED
1381     - dependency_template_subint_Vlan_vmi_1_pd_server_1b_pd_server_1b_port_0_nested_vlan:
1382         capability: tosca.capabilities.Node
1383         node: tosca.nodes.Root
1384         relationship: tosca.relationships.DependsOn
1385         occurrences:
1386         - 0
1387         - UNBOUNDED
1388     - subinterface_link_template_subint_Vlan_vmi_1_pd_server_1b_pd_server_1b_port_0_nested_vlan:
1389         capability: tosca.capabilities.network.Linkable
1390         relationship: tosca.relationships.network.LinksTo
1391         occurrences:
1392         - 1
1393         - 1
1394     - dependency_pd_server_1b:
1395         capability: tosca.capabilities.Node
1396         node: tosca.nodes.Root
1397         relationship: tosca.relationships.DependsOn
1398         occurrences:
1399         - 0
1400         - UNBOUNDED
1401     - local_storage_pd_server_1b:
1402         capability: tosca.capabilities.Attachment
1403         node: tosca.nodes.BlockStorage
1404         relationship: tosca.relationships.AttachesTo
1405         occurrences:
1406         - 0
1407         - UNBOUNDED
1408     - dependency_pd_server_1b_pd_server_1b_port_0:
1409         capability: tosca.capabilities.Node
1410         node: tosca.nodes.Root
1411         relationship: tosca.relationships.DependsOn
1412         occurrences:
1413         - 0
1414         - UNBOUNDED
1415     - link_pd_server_1b_pd_server_1b_port_0:
1416         capability: tosca.capabilities.network.Linkable
1417         relationship: tosca.relationships.network.LinksTo
1418         occurrences:
1419         - 1
1420         - 1
1421     capabilities:
1422       disk.device.read.bytes_pd_server_1b:
1423         type: org.openecomp.capabilities.metric.Ceilometer
1424         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1425         occurrences:
1426         - 1
1427         - UNBOUNDED
1428       host_pd_server_1b:
1429         type: tosca.capabilities.Container
1430         valid_source_types:
1431         - tosca.nodes.SoftwareComponent
1432         occurrences:
1433         - 1
1434         - UNBOUNDED
1435       disk.read.bytes.rate_pd_server_1b:
1436         type: org.openecomp.capabilities.metric.Ceilometer
1437         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1438         occurrences:
1439         - 1
1440         - UNBOUNDED
1441       disk.allocation_pd_server_1b:
1442         type: org.openecomp.capabilities.metric.Ceilometer
1443         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1444         occurrences:
1445         - 1
1446         - UNBOUNDED
1447       cpu.delta_pd_server_1b:
1448         type: org.openecomp.capabilities.metric.Ceilometer
1449         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1450         occurrences:
1451         - 1
1452         - UNBOUNDED
1453       disk.device.read.requests_pd_server_1b:
1454         type: org.openecomp.capabilities.metric.Ceilometer
1455         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1456         occurrences:
1457         - 1
1458         - UNBOUNDED
1459       network.incoming.packets.rate_pd_server_1b_pd_server_1b_port_0:
1460         type: org.openecomp.capabilities.metric.Ceilometer
1461         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1462         occurrences:
1463         - 1
1464         - UNBOUNDED
1465       binding_pd_server_1b_pd_server_1b_port_0:
1466         type: tosca.capabilities.network.Bindable
1467         valid_source_types:
1468         - org.openecomp.resource.cp.nodes.heat.network.contrailV2.VLANSubInterface
1469         - org.openecomp.resource.cp.nodes.heat.network.v2.contrailV2.VLANSubInterface
1470         occurrences:
1471         - 0
1472         - UNBOUNDED
1473       feature_pd_server_1b:
1474         type: tosca.capabilities.Node
1475         occurrences:
1476         - 1
1477         - UNBOUNDED
1478       disk.device.iops_pd_server_1b:
1479         type: org.openecomp.capabilities.metric.Ceilometer
1480         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1481         occurrences:
1482         - 1
1483         - UNBOUNDED
1484       cpu_pd_server_1b:
1485         type: org.openecomp.capabilities.metric.Ceilometer
1486         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1487         occurrences:
1488         - 1
1489         - UNBOUNDED
1490       disk.write.bytes.rate_pd_server_1b:
1491         type: org.openecomp.capabilities.metric.Ceilometer
1492         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1493         occurrences:
1494         - 1
1495         - UNBOUNDED
1496       feature_template_subint_Vlan_vmi_1_pd_server_1b_pd_server_1b_port_0_nested_vlan:
1497         type: tosca.capabilities.Node
1498         occurrences:
1499         - 1
1500         - UNBOUNDED
1501       disk.device.read.requests.rate_pd_server_1b:
1502         type: org.openecomp.capabilities.metric.Ceilometer
1503         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1504         occurrences:
1505         - 1
1506         - UNBOUNDED
1507       endpoint_pd_server_1b:
1508         type: tosca.capabilities.Endpoint.Admin
1509         occurrences:
1510         - 1
1511         - UNBOUNDED
1512       disk.device.allocation_pd_server_1b:
1513         type: org.openecomp.capabilities.metric.Ceilometer
1514         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1515         occurrences:
1516         - 1
1517         - UNBOUNDED
1518       memory.usage_pd_server_1b:
1519         type: org.openecomp.capabilities.metric.Ceilometer
1520         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1521         occurrences:
1522         - 1
1523         - UNBOUNDED
1524       network.incoming.bytes_pd_server_1b_pd_server_1b_port_0:
1525         type: org.openecomp.capabilities.metric.Ceilometer
1526         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1527         occurrences:
1528         - 1
1529         - UNBOUNDED
1530       memory_pd_server_1b:
1531         type: org.openecomp.capabilities.metric.Ceilometer
1532         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1533         occurrences:
1534         - 1
1535         - UNBOUNDED
1536       disk.device.read.bytes.rate_pd_server_1b:
1537         type: org.openecomp.capabilities.metric.Ceilometer
1538         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1539         occurrences:
1540         - 1
1541         - UNBOUNDED
1542       disk.device.latency_pd_server_1b:
1543         type: org.openecomp.capabilities.metric.Ceilometer
1544         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1545         occurrences:
1546         - 1
1547         - UNBOUNDED
1548       disk.read.bytes_pd_server_1b:
1549         type: org.openecomp.capabilities.metric.Ceilometer
1550         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1551         occurrences:
1552         - 1
1553         - UNBOUNDED
1554       network.incoming.bytes.rate_pd_server_1b_pd_server_1b_port_0:
1555         type: org.openecomp.capabilities.metric.Ceilometer
1556         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1557         occurrences:
1558         - 1
1559         - UNBOUNDED
1560       disk.device.usage_pd_server_1b:
1561         type: org.openecomp.capabilities.metric.Ceilometer
1562         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1563         occurrences:
1564         - 1
1565         - UNBOUNDED
1566       disk.device.write.requests_pd_server_1b:
1567         type: org.openecomp.capabilities.metric.Ceilometer
1568         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1569         occurrences:
1570         - 1
1571         - UNBOUNDED
1572       disk.latency_pd_server_1b:
1573         type: org.openecomp.capabilities.metric.Ceilometer
1574         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1575         occurrences:
1576         - 1
1577         - UNBOUNDED
1578       feature_pd_server_1b_pd_server_1b_port_0_nested_vlan:
1579         type: tosca.capabilities.Node
1580         occurrences:
1581         - 1
1582         - UNBOUNDED
1583       disk.ephemeral.size_pd_server_1b:
1584         type: org.openecomp.capabilities.metric.Ceilometer
1585         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1586         occurrences:
1587         - 1
1588         - UNBOUNDED
1589       forwarder_pd_server_1b_pd_server_1b_port_0:
1590         type: org.openecomp.capabilities.Forwarder
1591         occurrences:
1592         - 1
1593         - UNBOUNDED
1594       network.outgoing.bytes_pd_server_1b_pd_server_1b_port_0:
1595         type: org.openecomp.capabilities.metric.Ceilometer
1596         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1597         occurrences:
1598         - 1
1599         - UNBOUNDED
1600       scalable_pd_server_1b:
1601         type: tosca.capabilities.Scalable
1602         occurrences:
1603         - 1
1604         - UNBOUNDED
1605       disk.write.requests_pd_server_1b:
1606         type: org.openecomp.capabilities.metric.Ceilometer
1607         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1608         occurrences:
1609         - 1
1610         - UNBOUNDED
1611       disk.device.write.bytes.rate_pd_server_1b:
1612         type: org.openecomp.capabilities.metric.Ceilometer
1613         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1614         occurrences:
1615         - 1
1616         - UNBOUNDED
1617       disk.root.size_pd_server_1b:
1618         type: org.openecomp.capabilities.metric.Ceilometer
1619         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1620         occurrences:
1621         - 1
1622         - UNBOUNDED
1623       network.outgoing.bytes.rate_pd_server_1b_pd_server_1b_port_0:
1624         type: org.openecomp.capabilities.metric.Ceilometer
1625         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1626         occurrences:
1627         - 1
1628         - UNBOUNDED
1629       disk.iops_pd_server_1b:
1630         type: org.openecomp.capabilities.metric.Ceilometer
1631         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1632         occurrences:
1633         - 1
1634         - UNBOUNDED
1635       feature_pd_server_1b_pd_server_1b_port_0:
1636         type: tosca.capabilities.Node
1637         occurrences:
1638         - 1
1639         - UNBOUNDED
1640       disk.write.bytes_pd_server_1b:
1641         type: org.openecomp.capabilities.metric.Ceilometer
1642         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1643         occurrences:
1644         - 1
1645         - UNBOUNDED
1646       disk.device.write.bytes_pd_server_1b:
1647         type: org.openecomp.capabilities.metric.Ceilometer
1648         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1649         occurrences:
1650         - 1
1651         - UNBOUNDED
1652       os_pd_server_1b:
1653         type: tosca.capabilities.OperatingSystem
1654         occurrences:
1655         - 1
1656         - UNBOUNDED
1657       vcpus_pd_server_1b:
1658         type: org.openecomp.capabilities.metric.Ceilometer
1659         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1660         occurrences:
1661         - 1
1662         - UNBOUNDED
1663       instance_pd_server_1b:
1664         type: org.openecomp.capabilities.metric.Ceilometer
1665         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1666         occurrences:
1667         - 1
1668         - UNBOUNDED
1669       binding_pd_server_1b:
1670         type: tosca.capabilities.network.Bindable
1671         occurrences:
1672         - 1
1673         - UNBOUNDED
1674       cpu_util_pd_server_1b:
1675         type: org.openecomp.capabilities.metric.Ceilometer
1676         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1677         occurrences:
1678         - 1
1679         - UNBOUNDED
1680       network.outpoing.packets_pd_server_1b_pd_server_1b_port_0:
1681         type: org.openecomp.capabilities.metric.Ceilometer
1682         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1683         occurrences:
1684         - 1
1685         - UNBOUNDED
1686       attachment_pd_server_1b_pd_server_1b_port_0:
1687         type: tosca.capabilities.Attachment
1688         occurrences:
1689         - 1
1690         - UNBOUNDED
1691       memory.resident_pd_server_1b:
1692         type: org.openecomp.capabilities.metric.Ceilometer
1693         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1694         occurrences:
1695         - 1
1696         - UNBOUNDED
1697       network.incoming.packets_pd_server_1b_pd_server_1b_port_0:
1698         type: org.openecomp.capabilities.metric.Ceilometer
1699         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1700         occurrences:
1701         - 1
1702         - UNBOUNDED
1703       disk.device.write.requests.rate_pd_server_1b:
1704         type: org.openecomp.capabilities.metric.Ceilometer
1705         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1706         occurrences:
1707         - 1
1708         - UNBOUNDED
1709       disk.device.capacity_pd_server_1b:
1710         type: org.openecomp.capabilities.metric.Ceilometer
1711         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1712         occurrences:
1713         - 1
1714         - UNBOUNDED
1715       disk.read.requests_pd_server_1b:
1716         type: org.openecomp.capabilities.metric.Ceilometer
1717         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1718         occurrences:
1719         - 1
1720         - UNBOUNDED
1721       disk.capacity_pd_server_1b:
1722         type: org.openecomp.capabilities.metric.Ceilometer
1723         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1724         occurrences:
1725         - 1
1726         - UNBOUNDED
1727       disk.usage_pd_server_1b:
1728         type: org.openecomp.capabilities.metric.Ceilometer
1729         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1730         occurrences:
1731         - 1
1732         - UNBOUNDED
1733       network.outgoing.packets.rate_pd_server_1b_pd_server_1b_port_0:
1734         type: org.openecomp.capabilities.metric.Ceilometer
1735         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1736         occurrences:
1737         - 1
1738         - UNBOUNDED
1739       disk.write.requests.rate_pd_server_1b:
1740         type: org.openecomp.capabilities.metric.Ceilometer
1741         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1742         occurrences:
1743         - 1
1744         - UNBOUNDED
1745   org.openecomp.resource.abstract.nodes.heat.nested_pattern5_levelTwo:
1746     derived_from: org.openecomp.resource.abstract.nodes.AbstractSubstitute
1747     properties:
1748       port_net:
1749         type: string
1750         description: port network
1751         required: true
1752         status: SUPPORTED
1753       ps_server_2b_ips:
1754         type: string
1755         required: true
1756         status: SUPPORTED
1757       ps_server_1b_ips:
1758         type: string
1759         required: true
1760         status: SUPPORTED
1761       packet_int_network_name:
1762         type: string
1763         description: network name
1764         required: true
1765         status: SUPPORTED
1766       security_group_name:
1767         type: list
1768         description: CMAUI1, CMAUI2 server names
1769         required: true
1770         status: SUPPORTED
1771         entry_schema:
1772           type: string
1773       availability_zone_0:
1774         type: string
1775         description: availabilityzone name
1776         required: true
1777         status: SUPPORTED
1778       ps_server_1b_flavor:
1779         type: string
1780         description: Flavor for PS server
1781         required: true
1782         status: SUPPORTED
1783       ps_server_1b_image:
1784         type: string
1785         description: Ps Image server
1786         required: true
1787         status: SUPPORTED
1788       sub_inf_net:
1789         type: string
1790         description: sub interface network
1791         required: true
1792         status: SUPPORTED
1793       ps_server_1b_names:
1794         type: list
1795         description: Ps server names
1796         required: true
1797         status: SUPPORTED
1798         entry_schema:
1799           type: string
1800       packet_ext_network_name:
1801         type: string
1802         description: network name
1803         required: true
1804         status: SUPPORTED
1805     requirements:
1806     - dependency_server_1b_ps_1:
1807         capability: tosca.capabilities.Node
1808         node: tosca.nodes.Root
1809         relationship: tosca.relationships.DependsOn
1810         occurrences:
1811         - 0
1812         - UNBOUNDED
1813     - local_storage_server_1b_ps_1:
1814         capability: tosca.capabilities.Attachment
1815         node: tosca.nodes.BlockStorage
1816         relationship: tosca.relationships.AttachesTo
1817         occurrences:
1818         - 0
1819         - UNBOUNDED
1820     - dependency_test_resourceGroup_1:
1821         capability: tosca.capabilities.Node
1822         node: tosca.nodes.Root
1823         relationship: tosca.relationships.DependsOn
1824         occurrences:
1825         - 0
1826         - UNBOUNDED
1827     - dependency_template_subint_Vlan_vmi_1_test_resourceGroup_1:
1828         capability: tosca.capabilities.Node
1829         node: tosca.nodes.Root
1830         relationship: tosca.relationships.DependsOn
1831         occurrences:
1832         - 0
1833         - UNBOUNDED
1834     - dependency_test_resourceGroup_2:
1835         capability: tosca.capabilities.Node
1836         node: tosca.nodes.Root
1837         relationship: tosca.relationships.DependsOn
1838         occurrences:
1839         - 0
1840         - UNBOUNDED
1841     - dependency_template_subint_Vlan_vmi_1_test_resourceGroup_2:
1842         capability: tosca.capabilities.Node
1843         node: tosca.nodes.Root
1844         relationship: tosca.relationships.DependsOn
1845         occurrences:
1846         - 0
1847         - UNBOUNDED
1848     - dependency_ps_server_1b_port_1:
1849         capability: tosca.capabilities.Node
1850         node: tosca.nodes.Root
1851         relationship: tosca.relationships.DependsOn
1852         occurrences:
1853         - 0
1854         - UNBOUNDED
1855     - dependency_ps_server_1b_1_port_1:
1856         capability: tosca.capabilities.Node
1857         node: tosca.nodes.Root
1858         relationship: tosca.relationships.DependsOn
1859         occurrences:
1860         - 0
1861         - UNBOUNDED
1862     - dependency_packet_ext_network:
1863         capability: tosca.capabilities.Node
1864         node: tosca.nodes.Root
1865         relationship: tosca.relationships.DependsOn
1866         occurrences:
1867         - 0
1868         - UNBOUNDED
1869     - dependency_packet_int_network:
1870         capability: tosca.capabilities.Node
1871         node: tosca.nodes.Root
1872         relationship: tosca.relationships.DependsOn
1873         occurrences:
1874         - 0
1875         - UNBOUNDED
1876     - dependency_server_1b_ps_2:
1877         capability: tosca.capabilities.Node
1878         node: tosca.nodes.Root
1879         relationship: tosca.relationships.DependsOn
1880         occurrences:
1881         - 0
1882         - UNBOUNDED
1883     - local_storage_server_1b_ps_2:
1884         capability: tosca.capabilities.Attachment
1885         node: tosca.nodes.BlockStorage
1886         relationship: tosca.relationships.AttachesTo
1887         occurrences:
1888         - 0
1889         - UNBOUNDED
1890     capabilities:
1891       disk.device.latency_server_1b_ps_1:
1892         type: org.openecomp.capabilities.metric.Ceilometer
1893         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1894         occurrences:
1895         - 1
1896         - UNBOUNDED
1897       disk.device.usage_server_1b_ps_1:
1898         type: org.openecomp.capabilities.metric.Ceilometer
1899         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1900         occurrences:
1901         - 1
1902         - UNBOUNDED
1903       disk.device.usage_server_1b_ps_2:
1904         type: org.openecomp.capabilities.metric.Ceilometer
1905         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1906         occurrences:
1907         - 1
1908         - UNBOUNDED
1909       disk.read.requests_server_1b_ps_1:
1910         type: org.openecomp.capabilities.metric.Ceilometer
1911         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1912         occurrences:
1913         - 1
1914         - UNBOUNDED
1915       disk.device.write.requests.rate_server_1b_ps_1:
1916         type: org.openecomp.capabilities.metric.Ceilometer
1917         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1918         occurrences:
1919         - 1
1920         - UNBOUNDED
1921       disk.read.requests_server_1b_ps_2:
1922         type: org.openecomp.capabilities.metric.Ceilometer
1923         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1924         occurrences:
1925         - 1
1926         - UNBOUNDED
1927       disk.device.write.requests.rate_server_1b_ps_2:
1928         type: org.openecomp.capabilities.metric.Ceilometer
1929         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1930         occurrences:
1931         - 1
1932         - UNBOUNDED
1933       binding_ps_server_1b_port_1:
1934         type: tosca.capabilities.network.Bindable
1935         valid_source_types:
1936         - org.openecomp.resource.cp.nodes.heat.network.contrailV2.VLANSubInterface
1937         - org.openecomp.resource.cp.nodes.heat.network.v2.contrailV2.VLANSubInterface
1938         occurrences:
1939         - 0
1940         - UNBOUNDED
1941       disk.read.bytes_server_1b_ps_1:
1942         type: org.openecomp.capabilities.metric.Ceilometer
1943         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1944         occurrences:
1945         - 1
1946         - UNBOUNDED
1947       disk.read.bytes_server_1b_ps_2:
1948         type: org.openecomp.capabilities.metric.Ceilometer
1949         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1950         occurrences:
1951         - 1
1952         - UNBOUNDED
1953       disk.device.latency_server_1b_ps_2:
1954         type: org.openecomp.capabilities.metric.Ceilometer
1955         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1956         occurrences:
1957         - 1
1958         - UNBOUNDED
1959       disk.root.size_server_1b_ps_1:
1960         type: org.openecomp.capabilities.metric.Ceilometer
1961         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1962         occurrences:
1963         - 1
1964         - UNBOUNDED
1965       disk.root.size_server_1b_ps_2:
1966         type: org.openecomp.capabilities.metric.Ceilometer
1967         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1968         occurrences:
1969         - 1
1970         - UNBOUNDED
1971       network.incoming.bytes.rate_ps_server_1b_port_1:
1972         type: org.openecomp.capabilities.metric.Ceilometer
1973         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1974         occurrences:
1975         - 1
1976         - UNBOUNDED
1977       disk.device.read.requests.rate_server_1b_ps_1:
1978         type: org.openecomp.capabilities.metric.Ceilometer
1979         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1980         occurrences:
1981         - 1
1982         - UNBOUNDED
1983       disk.device.read.requests.rate_server_1b_ps_2:
1984         type: org.openecomp.capabilities.metric.Ceilometer
1985         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1986         occurrences:
1987         - 1
1988         - UNBOUNDED
1989       feature_test_resourceGroup_1:
1990         type: tosca.capabilities.Node
1991         occurrences:
1992         - 1
1993         - UNBOUNDED
1994       network.incoming.bytes_ps_server_1b_port_1:
1995         type: org.openecomp.capabilities.metric.Ceilometer
1996         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1997         occurrences:
1998         - 1
1999         - UNBOUNDED
2000       attachment_packet_int_network:
2001         type: tosca.capabilities.Attachment
2002         occurrences:
2003         - 1
2004         - UNBOUNDED
2005       cpu.delta_server_1b_ps_2:
2006         type: org.openecomp.capabilities.metric.Ceilometer
2007         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2008         occurrences:
2009         - 1
2010         - UNBOUNDED
2011       memory.resident_server_1b_ps_2:
2012         type: org.openecomp.capabilities.metric.Ceilometer
2013         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2014         occurrences:
2015         - 1
2016         - UNBOUNDED
2017       cpu.delta_server_1b_ps_1:
2018         type: org.openecomp.capabilities.metric.Ceilometer
2019         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2020         occurrences:
2021         - 1
2022         - UNBOUNDED
2023       memory.resident_server_1b_ps_1:
2024         type: org.openecomp.capabilities.metric.Ceilometer
2025         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2026         occurrences:
2027         - 1
2028         - UNBOUNDED
2029       cpu_util_server_1b_ps_1:
2030         type: org.openecomp.capabilities.metric.Ceilometer
2031         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2032         occurrences:
2033         - 1
2034         - UNBOUNDED
2035       disk.device.write.bytes.rate_server_1b_ps_2:
2036         type: org.openecomp.capabilities.metric.Ceilometer
2037         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2038         occurrences:
2039         - 1
2040         - UNBOUNDED
2041       disk.device.write.bytes.rate_server_1b_ps_1:
2042         type: org.openecomp.capabilities.metric.Ceilometer
2043         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2044         occurrences:
2045         - 1
2046         - UNBOUNDED
2047       cpu_util_server_1b_ps_2:
2048         type: org.openecomp.capabilities.metric.Ceilometer
2049         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2050         occurrences:
2051         - 1
2052         - UNBOUNDED
2053       disk.ephemeral.size_server_1b_ps_1:
2054         type: org.openecomp.capabilities.metric.Ceilometer
2055         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2056         occurrences:
2057         - 1
2058         - UNBOUNDED
2059       disk.ephemeral.size_server_1b_ps_2:
2060         type: org.openecomp.capabilities.metric.Ceilometer
2061         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2062         occurrences:
2063         - 1
2064         - UNBOUNDED
2065       disk.capacity_server_1b_ps_2:
2066         type: org.openecomp.capabilities.metric.Ceilometer
2067         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2068         occurrences:
2069         - 1
2070         - UNBOUNDED
2071       memory_server_1b_ps_1:
2072         type: org.openecomp.capabilities.metric.Ceilometer
2073         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2074         occurrences:
2075         - 1
2076         - UNBOUNDED
2077       network.outgoing.packets.rate_ps_server_1b_port_1:
2078         type: org.openecomp.capabilities.metric.Ceilometer
2079         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2080         occurrences:
2081         - 1
2082         - UNBOUNDED
2083       disk.capacity_server_1b_ps_1:
2084         type: org.openecomp.capabilities.metric.Ceilometer
2085         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2086         occurrences:
2087         - 1
2088         - UNBOUNDED
2089       memory_server_1b_ps_2:
2090         type: org.openecomp.capabilities.metric.Ceilometer
2091         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2092         occurrences:
2093         - 1
2094         - UNBOUNDED
2095       instance_server_1b_ps_1:
2096         type: org.openecomp.capabilities.metric.Ceilometer
2097         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2098         occurrences:
2099         - 1
2100         - UNBOUNDED
2101       forwarder_ps_server_1b_port_1:
2102         type: org.openecomp.capabilities.Forwarder
2103         occurrences:
2104         - 1
2105         - UNBOUNDED
2106       link_packet_int_network:
2107         type: tosca.capabilities.network.Linkable
2108         occurrences:
2109         - 1
2110         - UNBOUNDED
2111       instance_server_1b_ps_2:
2112         type: org.openecomp.capabilities.metric.Ceilometer
2113         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2114         occurrences:
2115         - 1
2116         - UNBOUNDED
2117       network.outgoing.packets.rate_ps_server_1b_1_port_1:
2118         type: org.openecomp.capabilities.metric.Ceilometer
2119         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2120         occurrences:
2121         - 1
2122         - UNBOUNDED
2123       disk.device.capacity_server_1b_ps_1:
2124         type: org.openecomp.capabilities.metric.Ceilometer
2125         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2126         occurrences:
2127         - 1
2128         - UNBOUNDED
2129       end_point_packet_ext_network:
2130         type: tosca.capabilities.Endpoint
2131         occurrences:
2132         - 1
2133         - UNBOUNDED
2134       disk.device.capacity_server_1b_ps_2:
2135         type: org.openecomp.capabilities.metric.Ceilometer
2136         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2137         occurrences:
2138         - 1
2139         - UNBOUNDED
2140       network.outgoing.bytes_ps_server_1b_1_port_1:
2141         type: org.openecomp.capabilities.metric.Ceilometer
2142         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2143         occurrences:
2144         - 1
2145         - UNBOUNDED
2146       disk.device.iops_server_1b_ps_2:
2147         type: org.openecomp.capabilities.metric.Ceilometer
2148         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2149         occurrences:
2150         - 1
2151         - UNBOUNDED
2152       disk.device.iops_server_1b_ps_1:
2153         type: org.openecomp.capabilities.metric.Ceilometer
2154         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2155         occurrences:
2156         - 1
2157         - UNBOUNDED
2158       network.incoming.packets_ps_server_1b_port_1:
2159         type: org.openecomp.capabilities.metric.Ceilometer
2160         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2161         occurrences:
2162         - 1
2163         - UNBOUNDED
2164       network.outgoing.bytes.rate_ps_server_1b_port_1:
2165         type: org.openecomp.capabilities.metric.Ceilometer
2166         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2167         occurrences:
2168         - 1
2169         - UNBOUNDED
2170       network.outpoing.packets_ps_server_1b_port_1:
2171         type: org.openecomp.capabilities.metric.Ceilometer
2172         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2173         occurrences:
2174         - 1
2175         - UNBOUNDED
2176       endpoint_server_1b_ps_1:
2177         type: tosca.capabilities.Endpoint.Admin
2178         occurrences:
2179         - 1
2180         - UNBOUNDED
2181       network.incoming.packets.rate_ps_server_1b_1_port_1:
2182         type: org.openecomp.capabilities.metric.Ceilometer
2183         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2184         occurrences:
2185         - 1
2186         - UNBOUNDED
2187       network.incoming.bytes.rate_ps_server_1b_1_port_1:
2188         type: org.openecomp.capabilities.metric.Ceilometer
2189         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2190         occurrences:
2191         - 1
2192         - UNBOUNDED
2193       disk.device.allocation_server_1b_ps_1:
2194         type: org.openecomp.capabilities.metric.Ceilometer
2195         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2196         occurrences:
2197         - 1
2198         - UNBOUNDED
2199       endpoint_server_1b_ps_2:
2200         type: tosca.capabilities.Endpoint.Admin
2201         occurrences:
2202         - 1
2203         - UNBOUNDED
2204       disk.write.requests.rate_server_1b_ps_2:
2205         type: org.openecomp.capabilities.metric.Ceilometer
2206         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2207         occurrences:
2208         - 1
2209         - UNBOUNDED
2210       disk.write.requests.rate_server_1b_ps_1:
2211         type: org.openecomp.capabilities.metric.Ceilometer
2212         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2213         occurrences:
2214         - 1
2215         - UNBOUNDED
2216       host_server_1b_ps_2:
2217         type: tosca.capabilities.Container
2218         valid_source_types:
2219         - tosca.nodes.SoftwareComponent
2220         occurrences:
2221         - 1
2222         - UNBOUNDED
2223       host_server_1b_ps_1:
2224         type: tosca.capabilities.Container
2225         valid_source_types:
2226         - tosca.nodes.SoftwareComponent
2227         occurrences:
2228         - 1
2229         - UNBOUNDED
2230       attachment_ps_server_1b_1_port_1:
2231         type: tosca.capabilities.Attachment
2232         occurrences:
2233         - 1
2234         - UNBOUNDED
2235       feature_packet_int_network:
2236         type: tosca.capabilities.Node
2237         occurrences:
2238         - 1
2239         - UNBOUNDED
2240       disk.write.bytes.rate_server_1b_ps_1:
2241         type: org.openecomp.capabilities.metric.Ceilometer
2242         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2243         occurrences:
2244         - 1
2245         - UNBOUNDED
2246       disk.write.bytes_server_1b_ps_2:
2247         type: org.openecomp.capabilities.metric.Ceilometer
2248         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2249         occurrences:
2250         - 1
2251         - UNBOUNDED
2252       disk.device.write.bytes_server_1b_ps_2:
2253         type: org.openecomp.capabilities.metric.Ceilometer
2254         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2255         occurrences:
2256         - 1
2257         - UNBOUNDED
2258       disk.device.write.bytes_server_1b_ps_1:
2259         type: org.openecomp.capabilities.metric.Ceilometer
2260         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2261         occurrences:
2262         - 1
2263         - UNBOUNDED
2264       disk.write.bytes_server_1b_ps_1:
2265         type: org.openecomp.capabilities.metric.Ceilometer
2266         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2267         occurrences:
2268         - 1
2269         - UNBOUNDED
2270       disk.write.bytes.rate_server_1b_ps_2:
2271         type: org.openecomp.capabilities.metric.Ceilometer
2272         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2273         occurrences:
2274         - 1
2275         - UNBOUNDED
2276       disk.device.allocation_server_1b_ps_2:
2277         type: org.openecomp.capabilities.metric.Ceilometer
2278         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2279         occurrences:
2280         - 1
2281         - UNBOUNDED
2282       scalable_server_1b_ps_1:
2283         type: tosca.capabilities.Scalable
2284         occurrences:
2285         - 1
2286         - UNBOUNDED
2287       network.outpoing.packets_ps_server_1b_1_port_1:
2288         type: org.openecomp.capabilities.metric.Ceilometer
2289         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2290         occurrences:
2291         - 1
2292         - UNBOUNDED
2293       scalable_server_1b_ps_2:
2294         type: tosca.capabilities.Scalable
2295         occurrences:
2296         - 1
2297         - UNBOUNDED
2298       disk.allocation_server_1b_ps_2:
2299         type: org.openecomp.capabilities.metric.Ceilometer
2300         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2301         occurrences:
2302         - 1
2303         - UNBOUNDED
2304       disk.allocation_server_1b_ps_1:
2305         type: org.openecomp.capabilities.metric.Ceilometer
2306         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2307         occurrences:
2308         - 1
2309         - UNBOUNDED
2310       feature_server_1b_ps_2:
2311         type: tosca.capabilities.Node
2312         occurrences:
2313         - 1
2314         - UNBOUNDED
2315       feature_server_1b_ps_1:
2316         type: tosca.capabilities.Node
2317         occurrences:
2318         - 1
2319         - UNBOUNDED
2320       vcpus_server_1b_ps_1:
2321         type: org.openecomp.capabilities.metric.Ceilometer
2322         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2323         occurrences:
2324         - 1
2325         - UNBOUNDED
2326       network.outgoing.bytes.rate_ps_server_1b_1_port_1:
2327         type: org.openecomp.capabilities.metric.Ceilometer
2328         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2329         occurrences:
2330         - 1
2331         - UNBOUNDED
2332       vcpus_server_1b_ps_2:
2333         type: org.openecomp.capabilities.metric.Ceilometer
2334         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2335         occurrences:
2336         - 1
2337         - UNBOUNDED
2338       feature_template_subint_Vlan_vmi_1_test_resourceGroup_2:
2339         type: tosca.capabilities.Node
2340         occurrences:
2341         - 1
2342         - UNBOUNDED
2343       network.incoming.bytes_ps_server_1b_1_port_1:
2344         type: org.openecomp.capabilities.metric.Ceilometer
2345         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2346         occurrences:
2347         - 1
2348         - UNBOUNDED
2349       feature_template_subint_Vlan_vmi_1_test_resourceGroup_1:
2350         type: tosca.capabilities.Node
2351         occurrences:
2352         - 1
2353         - UNBOUNDED
2354       disk.read.bytes.rate_server_1b_ps_2:
2355         type: org.openecomp.capabilities.metric.Ceilometer
2356         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2357         occurrences:
2358         - 1
2359         - UNBOUNDED
2360       disk.read.bytes.rate_server_1b_ps_1:
2361         type: org.openecomp.capabilities.metric.Ceilometer
2362         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2363         occurrences:
2364         - 1
2365         - UNBOUNDED
2366       disk.iops_server_1b_ps_1:
2367         type: org.openecomp.capabilities.metric.Ceilometer
2368         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2369         occurrences:
2370         - 1
2371         - UNBOUNDED
2372       memory.usage_server_1b_ps_2:
2373         type: org.openecomp.capabilities.metric.Ceilometer
2374         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2375         occurrences:
2376         - 1
2377         - UNBOUNDED
2378       memory.usage_server_1b_ps_1:
2379         type: org.openecomp.capabilities.metric.Ceilometer
2380         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2381         occurrences:
2382         - 1
2383         - UNBOUNDED
2384       disk.iops_server_1b_ps_2:
2385         type: org.openecomp.capabilities.metric.Ceilometer
2386         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2387         occurrences:
2388         - 1
2389         - UNBOUNDED
2390       disk.write.requests_server_1b_ps_1:
2391         type: org.openecomp.capabilities.metric.Ceilometer
2392         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2393         occurrences:
2394         - 1
2395         - UNBOUNDED
2396       disk.write.requests_server_1b_ps_2:
2397         type: org.openecomp.capabilities.metric.Ceilometer
2398         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2399         occurrences:
2400         - 1
2401         - UNBOUNDED
2402       disk.latency_server_1b_ps_2:
2403         type: org.openecomp.capabilities.metric.Ceilometer
2404         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2405         occurrences:
2406         - 1
2407         - UNBOUNDED
2408       disk.latency_server_1b_ps_1:
2409         type: org.openecomp.capabilities.metric.Ceilometer
2410         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2411         occurrences:
2412         - 1
2413         - UNBOUNDED
2414       network.incoming.packets.rate_ps_server_1b_port_1:
2415         type: org.openecomp.capabilities.metric.Ceilometer
2416         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2417         occurrences:
2418         - 1
2419         - UNBOUNDED
2420       binding_server_1b_ps_1:
2421         type: tosca.capabilities.network.Bindable
2422         occurrences:
2423         - 1
2424         - UNBOUNDED
2425       link_packet_ext_network:
2426         type: tosca.capabilities.network.Linkable
2427         occurrences:
2428         - 1
2429         - UNBOUNDED
2430       binding_server_1b_ps_2:
2431         type: tosca.capabilities.network.Bindable
2432         occurrences:
2433         - 1
2434         - UNBOUNDED
2435       disk.device.write.requests_server_1b_ps_1:
2436         type: org.openecomp.capabilities.metric.Ceilometer
2437         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2438         occurrences:
2439         - 1
2440         - UNBOUNDED
2441       disk.device.read.requests_server_1b_ps_2:
2442         type: org.openecomp.capabilities.metric.Ceilometer
2443         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2444         occurrences:
2445         - 1
2446         - UNBOUNDED
2447       disk.device.write.requests_server_1b_ps_2:
2448         type: org.openecomp.capabilities.metric.Ceilometer
2449         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2450         occurrences:
2451         - 1
2452         - UNBOUNDED
2453       disk.device.read.requests_server_1b_ps_1:
2454         type: org.openecomp.capabilities.metric.Ceilometer
2455         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2456         occurrences:
2457         - 1
2458         - UNBOUNDED
2459       end_point_packet_int_network:
2460         type: tosca.capabilities.Endpoint
2461         occurrences:
2462         - 1
2463         - UNBOUNDED
2464       attachment_ps_server_1b_port_1:
2465         type: tosca.capabilities.Attachment
2466         occurrences:
2467         - 1
2468         - UNBOUNDED
2469       attachment_packet_ext_network:
2470         type: tosca.capabilities.Attachment
2471         occurrences:
2472         - 1
2473         - UNBOUNDED
2474       network.incoming.packets_ps_server_1b_1_port_1:
2475         type: org.openecomp.capabilities.metric.Ceilometer
2476         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2477         occurrences:
2478         - 1
2479         - UNBOUNDED
2480       os_server_1b_ps_2:
2481         type: tosca.capabilities.OperatingSystem
2482         occurrences:
2483         - 1
2484         - UNBOUNDED
2485       os_server_1b_ps_1:
2486         type: tosca.capabilities.OperatingSystem
2487         occurrences:
2488         - 1
2489         - UNBOUNDED
2490       binding_ps_server_1b_1_port_1:
2491         type: tosca.capabilities.network.Bindable
2492         valid_source_types:
2493         - org.openecomp.resource.cp.nodes.heat.network.contrailV2.VLANSubInterface
2494         - org.openecomp.resource.cp.nodes.heat.network.v2.contrailV2.VLANSubInterface
2495         occurrences:
2496         - 0
2497         - UNBOUNDED
2498       feature_test_resourceGroup_2:
2499         type: tosca.capabilities.Node
2500         occurrences:
2501         - 1
2502         - UNBOUNDED
2503       network.outgoing.bytes_ps_server_1b_port_1:
2504         type: org.openecomp.capabilities.metric.Ceilometer
2505         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2506         occurrences:
2507         - 1
2508         - UNBOUNDED
2509       feature_ps_server_1b_1_port_1:
2510         type: tosca.capabilities.Node
2511         occurrences:
2512         - 1
2513         - UNBOUNDED
2514       disk.usage_server_1b_ps_2:
2515         type: org.openecomp.capabilities.metric.Ceilometer
2516         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2517         occurrences:
2518         - 1
2519         - UNBOUNDED
2520       disk.usage_server_1b_ps_1:
2521         type: org.openecomp.capabilities.metric.Ceilometer
2522         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2523         occurrences:
2524         - 1
2525         - UNBOUNDED
2526       forwarder_ps_server_1b_1_port_1:
2527         type: org.openecomp.capabilities.Forwarder
2528         occurrences:
2529         - 1
2530         - UNBOUNDED
2531       disk.device.read.bytes_server_1b_ps_2:
2532         type: org.openecomp.capabilities.metric.Ceilometer
2533         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2534         occurrences:
2535         - 1
2536         - UNBOUNDED
2537       disk.device.read.bytes_server_1b_ps_1:
2538         type: org.openecomp.capabilities.metric.Ceilometer
2539         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2540         occurrences:
2541         - 1
2542         - UNBOUNDED
2543       cpu_server_1b_ps_2:
2544         type: org.openecomp.capabilities.metric.Ceilometer
2545         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2546         occurrences:
2547         - 1
2548         - UNBOUNDED
2549       cpu_server_1b_ps_1:
2550         type: org.openecomp.capabilities.metric.Ceilometer
2551         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2552         occurrences:
2553         - 1
2554         - UNBOUNDED
2555       feature_packet_ext_network:
2556         type: tosca.capabilities.Node
2557         occurrences:
2558         - 1
2559         - UNBOUNDED
2560       feature_ps_server_1b_port_1:
2561         type: tosca.capabilities.Node
2562         occurrences:
2563         - 1
2564         - UNBOUNDED
2565       disk.device.read.bytes.rate_server_1b_ps_1:
2566         type: org.openecomp.capabilities.metric.Ceilometer
2567         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2568         occurrences:
2569         - 1
2570         - UNBOUNDED
2571       disk.device.read.bytes.rate_server_1b_ps_2:
2572         type: org.openecomp.capabilities.metric.Ceilometer
2573         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2574         occurrences:
2575         - 1
2576         - UNBOUNDED
2577   org.openecomp.resource.abstract.nodes.ps_server_1b:
2578     derived_from: org.openecomp.resource.abstract.nodes.VFC
2579     properties:
2580       port_ps_server_1b_port_1_network_role_tag:
2581         type: string
2582         required: true
2583         status: SUPPORTED
2584       port_ps_server_1b_port_1_related_networks:
2585         type: list
2586         required: true
2587         status: SUPPORTED
2588         entry_schema:
2589           type: org.openecomp.datatypes.network.RelatedNetworksAssignments
2590       subinterface_nested_vlan_service_template_filter_count:
2591         type: list
2592         required: true
2593         status: SUPPORTED
2594         entry_schema:
2595           type: float
2596       index_value:
2597         type: integer
2598         description: Index value of this substitution service template runtime instance
2599         required: false
2600         default: 0
2601         status: SUPPORTED
2602         constraints:
2603         - greater_or_equal: 0
2604       port_ps_server_1b_port_1_ip_requirements:
2605         type: list
2606         required: true
2607         status: SUPPORTED
2608         entry_schema:
2609           type: org.openecomp.datatypes.network.IpRequirements
2610       vm_flavor_name:
2611         type: string
2612         required: true
2613         status: SUPPORTED
2614       port_ps_server_1b_port_1_mac_requirements:
2615         type: org.openecomp.datatypes.network.MacRequirements
2616         required: true
2617         status: SUPPORTED
2618       port_ps_server_1b_port_1_network_role:
2619         type: string
2620         required: true
2621         status: SUPPORTED
2622       subinterface_nested_vlan_net1:
2623         type: list
2624         required: true
2625         status: SUPPORTED
2626         entry_schema:
2627           type: string
2628       vm_image_name:
2629         type: string
2630         required: true
2631         status: SUPPORTED
2632       port_ps_server_1b_port_1_replacement_policy:
2633         type: list
2634         required: true
2635         status: SUPPORTED
2636         entry_schema:
2637           type: string
2638       port_ps_server_1b_port_1_exCP_naming:
2639         type: org.openecomp.datatypes.Naming
2640         required: true
2641         status: SUPPORTED
2642       port_ps_server_1b_port_1_fixed_ips:
2643         type: list
2644         required: true
2645         status: SUPPORTED
2646         entry_schema:
2647           type: org.openecomp.datatypes.heat.neutron.port.FixedIps
2648       subinterface_nested_vlan_parent_interface:
2649         type: list
2650         required: true
2651         status: SUPPORTED
2652         entry_schema:
2653           type: string
2654       port_ps_server_1b_port_1_order:
2655         type: integer
2656         required: true
2657         status: SUPPORTED
2658       port_ps_server_1b_port_1_subnetpoolid:
2659         type: string
2660         required: true
2661         status: SUPPORTED
2662       port_ps_server_1b_port_1_network:
2663         type: list
2664         required: true
2665         status: SUPPORTED
2666         entry_schema:
2667           type: string
2668       compute_ps_server_1b_availability_zone:
2669         type: list
2670         required: true
2671         status: SUPPORTED
2672         entry_schema:
2673           type: string
2674       port_ps_server_1b_port_1_vlan_requirements:
2675         type: list
2676         required: true
2677         status: SUPPORTED
2678         entry_schema:
2679           type: org.openecomp.datatypes.network.VlanRequirements
2680       compute_ps_server_1b_name:
2681         type: list
2682         required: true
2683         status: SUPPORTED
2684         entry_schema:
2685           type: string
2686     requirements:
2687     - dependency_ps_server_1b:
2688         capability: tosca.capabilities.Node
2689         node: tosca.nodes.Root
2690         relationship: tosca.relationships.DependsOn
2691         occurrences:
2692         - 0
2693         - UNBOUNDED
2694     - local_storage_ps_server_1b:
2695         capability: tosca.capabilities.Attachment
2696         node: tosca.nodes.BlockStorage
2697         relationship: tosca.relationships.AttachesTo
2698         occurrences:
2699         - 0
2700         - UNBOUNDED
2701     - dependency_ps_server_1b_ps_server_1b_port_1:
2702         capability: tosca.capabilities.Node
2703         node: tosca.nodes.Root
2704         relationship: tosca.relationships.DependsOn
2705         occurrences:
2706         - 0
2707         - UNBOUNDED
2708     - link_ps_server_1b_ps_server_1b_port_1:
2709         capability: tosca.capabilities.network.Linkable
2710         relationship: tosca.relationships.network.LinksTo
2711         occurrences:
2712         - 1
2713         - 1
2714     - dependency_ps_server_1b_ps_server_1b_port_1_nested_vlan:
2715         capability: tosca.capabilities.Node
2716         node: tosca.nodes.Root
2717         relationship: tosca.relationships.DependsOn
2718         occurrences:
2719         - 0
2720         - UNBOUNDED
2721     - dependency_template_subint_Vlan_vmi_1_ps_server_1b_ps_server_1b_port_1_nested_vlan:
2722         capability: tosca.capabilities.Node
2723         node: tosca.nodes.Root
2724         relationship: tosca.relationships.DependsOn
2725         occurrences:
2726         - 0
2727         - UNBOUNDED
2728     - subinterface_link_template_subint_Vlan_vmi_1_ps_server_1b_ps_server_1b_port_1_nested_vlan:
2729         capability: tosca.capabilities.network.Linkable
2730         relationship: tosca.relationships.network.LinksTo
2731         occurrences:
2732         - 1
2733         - 1
2734     capabilities:
2735       disk.write.bytes.rate_ps_server_1b:
2736         type: org.openecomp.capabilities.metric.Ceilometer
2737         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2738         occurrences:
2739         - 1
2740         - UNBOUNDED
2741       disk.device.usage_ps_server_1b:
2742         type: org.openecomp.capabilities.metric.Ceilometer
2743         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2744         occurrences:
2745         - 1
2746         - UNBOUNDED
2747       disk.device.allocation_ps_server_1b:
2748         type: org.openecomp.capabilities.metric.Ceilometer
2749         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2750         occurrences:
2751         - 1
2752         - UNBOUNDED
2753       disk.device.write.requests_ps_server_1b:
2754         type: org.openecomp.capabilities.metric.Ceilometer
2755         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2756         occurrences:
2757         - 1
2758         - UNBOUNDED
2759       cpu_util_ps_server_1b:
2760         type: org.openecomp.capabilities.metric.Ceilometer
2761         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2762         occurrences:
2763         - 1
2764         - UNBOUNDED
2765       scalable_ps_server_1b:
2766         type: tosca.capabilities.Scalable
2767         occurrences:
2768         - 1
2769         - UNBOUNDED
2770       network.outgoing.bytes_ps_server_1b_ps_server_1b_port_1:
2771         type: org.openecomp.capabilities.metric.Ceilometer
2772         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2773         occurrences:
2774         - 1
2775         - UNBOUNDED
2776       disk.device.read.bytes.rate_ps_server_1b:
2777         type: org.openecomp.capabilities.metric.Ceilometer
2778         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2779         occurrences:
2780         - 1
2781         - UNBOUNDED
2782       disk.device.latency_ps_server_1b:
2783         type: org.openecomp.capabilities.metric.Ceilometer
2784         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2785         occurrences:
2786         - 1
2787         - UNBOUNDED
2788       network.outgoing.packets.rate_ps_server_1b_ps_server_1b_port_1:
2789         type: org.openecomp.capabilities.metric.Ceilometer
2790         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2791         occurrences:
2792         - 1
2793         - UNBOUNDED
2794       disk.device.iops_ps_server_1b:
2795         type: org.openecomp.capabilities.metric.Ceilometer
2796         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2797         occurrences:
2798         - 1
2799         - UNBOUNDED
2800       disk.device.capacity_ps_server_1b:
2801         type: org.openecomp.capabilities.metric.Ceilometer
2802         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2803         occurrences:
2804         - 1
2805         - UNBOUNDED
2806       instance_ps_server_1b:
2807         type: org.openecomp.capabilities.metric.Ceilometer
2808         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2809         occurrences:
2810         - 1
2811         - UNBOUNDED
2812       cpu_ps_server_1b:
2813         type: org.openecomp.capabilities.metric.Ceilometer
2814         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2815         occurrences:
2816         - 1
2817         - UNBOUNDED
2818       disk.device.write.bytes_ps_server_1b:
2819         type: org.openecomp.capabilities.metric.Ceilometer
2820         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2821         occurrences:
2822         - 1
2823         - UNBOUNDED
2824       disk.read.bytes.rate_ps_server_1b:
2825         type: org.openecomp.capabilities.metric.Ceilometer
2826         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2827         occurrences:
2828         - 1
2829         - UNBOUNDED
2830       disk.device.read.requests_ps_server_1b:
2831         type: org.openecomp.capabilities.metric.Ceilometer
2832         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2833         occurrences:
2834         - 1
2835         - UNBOUNDED
2836       host_ps_server_1b:
2837         type: tosca.capabilities.Container
2838         valid_source_types:
2839         - tosca.nodes.SoftwareComponent
2840         occurrences:
2841         - 1
2842         - UNBOUNDED
2843       disk.usage_ps_server_1b:
2844         type: org.openecomp.capabilities.metric.Ceilometer
2845         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2846         occurrences:
2847         - 1
2848         - UNBOUNDED
2849       disk.read.requests_ps_server_1b:
2850         type: org.openecomp.capabilities.metric.Ceilometer
2851         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2852         occurrences:
2853         - 1
2854         - UNBOUNDED
2855       disk.device.read.requests.rate_ps_server_1b:
2856         type: org.openecomp.capabilities.metric.Ceilometer
2857         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2858         occurrences:
2859         - 1
2860         - UNBOUNDED
2861       disk.capacity_ps_server_1b:
2862         type: org.openecomp.capabilities.metric.Ceilometer
2863         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2864         occurrences:
2865         - 1
2866         - UNBOUNDED
2867       network.incoming.bytes_ps_server_1b_ps_server_1b_port_1:
2868         type: org.openecomp.capabilities.metric.Ceilometer
2869         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2870         occurrences:
2871         - 1
2872         - UNBOUNDED
2873       disk.write.requests.rate_ps_server_1b:
2874         type: org.openecomp.capabilities.metric.Ceilometer
2875         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2876         occurrences:
2877         - 1
2878         - UNBOUNDED
2879       disk.device.read.bytes_ps_server_1b:
2880         type: org.openecomp.capabilities.metric.Ceilometer
2881         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2882         occurrences:
2883         - 1
2884         - UNBOUNDED
2885       attachment_ps_server_1b_ps_server_1b_port_1:
2886         type: tosca.capabilities.Attachment
2887         occurrences:
2888         - 1
2889         - UNBOUNDED
2890       disk.device.write.requests.rate_ps_server_1b:
2891         type: org.openecomp.capabilities.metric.Ceilometer
2892         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2893         occurrences:
2894         - 1
2895         - UNBOUNDED
2896       network.incoming.packets_ps_server_1b_ps_server_1b_port_1:
2897         type: org.openecomp.capabilities.metric.Ceilometer
2898         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2899         occurrences:
2900         - 1
2901         - UNBOUNDED
2902       disk.root.size_ps_server_1b:
2903         type: org.openecomp.capabilities.metric.Ceilometer
2904         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2905         occurrences:
2906         - 1
2907         - UNBOUNDED
2908       feature_ps_server_1b_ps_server_1b_port_1_nested_vlan:
2909         type: tosca.capabilities.Node
2910         occurrences:
2911         - 1
2912         - UNBOUNDED
2913       binding_ps_server_1b:
2914         type: tosca.capabilities.network.Bindable
2915         occurrences:
2916         - 1
2917         - UNBOUNDED
2918       memory.resident_ps_server_1b:
2919         type: org.openecomp.capabilities.metric.Ceilometer
2920         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2921         occurrences:
2922         - 1
2923         - UNBOUNDED
2924       memory_ps_server_1b:
2925         type: org.openecomp.capabilities.metric.Ceilometer
2926         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2927         occurrences:
2928         - 1
2929         - UNBOUNDED
2930       disk.write.bytes_ps_server_1b:
2931         type: org.openecomp.capabilities.metric.Ceilometer
2932         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2933         occurrences:
2934         - 1
2935         - UNBOUNDED
2936       disk.device.write.bytes.rate_ps_server_1b:
2937         type: org.openecomp.capabilities.metric.Ceilometer
2938         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2939         occurrences:
2940         - 1
2941         - UNBOUNDED
2942       disk.read.bytes_ps_server_1b:
2943         type: org.openecomp.capabilities.metric.Ceilometer
2944         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2945         occurrences:
2946         - 1
2947         - UNBOUNDED
2948       network.outgoing.bytes.rate_ps_server_1b_ps_server_1b_port_1:
2949         type: org.openecomp.capabilities.metric.Ceilometer
2950         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2951         occurrences:
2952         - 1
2953         - UNBOUNDED
2954       feature_ps_server_1b:
2955         type: tosca.capabilities.Node
2956         occurrences:
2957         - 1
2958         - UNBOUNDED
2959       os_ps_server_1b:
2960         type: tosca.capabilities.OperatingSystem
2961         occurrences:
2962         - 1
2963         - UNBOUNDED
2964       forwarder_ps_server_1b_ps_server_1b_port_1:
2965         type: org.openecomp.capabilities.Forwarder
2966         occurrences:
2967         - 1
2968         - UNBOUNDED
2969       disk.iops_ps_server_1b:
2970         type: org.openecomp.capabilities.metric.Ceilometer
2971         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2972         occurrences:
2973         - 1
2974         - UNBOUNDED
2975       disk.allocation_ps_server_1b:
2976         type: org.openecomp.capabilities.metric.Ceilometer
2977         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2978         occurrences:
2979         - 1
2980         - UNBOUNDED
2981       disk.write.requests_ps_server_1b:
2982         type: org.openecomp.capabilities.metric.Ceilometer
2983         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2984         occurrences:
2985         - 1
2986         - UNBOUNDED
2987       network.incoming.packets.rate_ps_server_1b_ps_server_1b_port_1:
2988         type: org.openecomp.capabilities.metric.Ceilometer
2989         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2990         occurrences:
2991         - 1
2992         - UNBOUNDED
2993       binding_ps_server_1b_ps_server_1b_port_1:
2994         type: tosca.capabilities.network.Bindable
2995         valid_source_types:
2996         - org.openecomp.resource.cp.nodes.heat.network.contrailV2.VLANSubInterface
2997         - org.openecomp.resource.cp.nodes.heat.network.v2.contrailV2.VLANSubInterface
2998         occurrences:
2999         - 0
3000         - UNBOUNDED
3001       memory.usage_ps_server_1b:
3002         type: org.openecomp.capabilities.metric.Ceilometer
3003         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
3004         occurrences:
3005         - 1
3006         - UNBOUNDED
3007       disk.latency_ps_server_1b:
3008         type: org.openecomp.capabilities.metric.Ceilometer
3009         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
3010         occurrences:
3011         - 1
3012         - UNBOUNDED
3013       network.outpoing.packets_ps_server_1b_ps_server_1b_port_1:
3014         type: org.openecomp.capabilities.metric.Ceilometer
3015         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
3016         occurrences:
3017         - 1
3018         - UNBOUNDED
3019       endpoint_ps_server_1b:
3020         type: tosca.capabilities.Endpoint.Admin
3021         occurrences:
3022         - 1
3023         - UNBOUNDED
3024       feature_template_subint_Vlan_vmi_1_ps_server_1b_ps_server_1b_port_1_nested_vlan:
3025         type: tosca.capabilities.Node
3026         occurrences:
3027         - 1
3028         - UNBOUNDED
3029       vcpus_ps_server_1b:
3030         type: org.openecomp.capabilities.metric.Ceilometer
3031         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
3032         occurrences:
3033         - 1
3034         - UNBOUNDED
3035       network.incoming.bytes.rate_ps_server_1b_ps_server_1b_port_1:
3036         type: org.openecomp.capabilities.metric.Ceilometer
3037         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
3038         occurrences:
3039         - 1
3040         - UNBOUNDED
3041       cpu.delta_ps_server_1b:
3042         type: org.openecomp.capabilities.metric.Ceilometer
3043         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
3044         occurrences:
3045         - 1
3046         - UNBOUNDED
3047       disk.ephemeral.size_ps_server_1b:
3048         type: org.openecomp.capabilities.metric.Ceilometer
3049         description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
3050         occurrences:
3051         - 1
3052         - UNBOUNDED
3053       feature_ps_server_1b_ps_server_1b_port_1:
3054         type: tosca.capabilities.Node
3055         occurrences:
3056         - 1
3057         - UNBOUNDED
3058   org.openecomp.resource.abstract.nodes.heat.subinterface.nested_vlan:
3059     derived_from: org.openecomp.resource.abstract.nodes.AbstractSubstitute
3060     properties:
3061       vlan_ids:
3062         type: string
3063         required: true
3064         status: SUPPORTED
3065       parent_interface:
3066         type: string
3067         required: true
3068         status: SUPPORTED
3069       virtual_ipv6_address:
3070         type: string
3071         required: true
3072         status: SUPPORTED
3073       virtual_ip_address:
3074         type: string
3075         required: true
3076         status: SUPPORTED
3077       lb_st_vlan_type_oam:
3078         type: string
3079         description: dummy
3080         required: true
3081         status: SUPPORTED
3082       mac_address:
3083         type: string
3084         required: true
3085         status: SUPPORTED
3086       net1:
3087         type: string
3088         required: true
3089         status: SUPPORTED
3090       subinterface_name_prefix:
3091         type: string
3092         required: true
3093         status: SUPPORTED
3094       subinterface_instance_index:
3095         type: float
3096         required: true
3097         status: SUPPORTED
3098     requirements:
3099     - dependency_template_subint_Vlan_vmi_1:
3100         capability: tosca.capabilities.Node
3101         node: tosca.nodes.Root
3102         relationship: tosca.relationships.DependsOn
3103         occurrences:
3104         - 0
3105         - UNBOUNDED
3106     - subinterface_link_template_subint_Vlan_vmi_1:
3107         capability: tosca.capabilities.network.Linkable
3108         relationship: tosca.relationships.network.LinksTo
3109         occurrences:
3110         - 1
3111         - 1
3112     - binding_template_subint_Vlan_vmi_1:
3113         capability: tosca.capabilities.network.Bindable
3114         node: org.openecomp.resource.cp.nodes.network.Port
3115         relationship: tosca.relationships.network.BindsTo
3116         occurrences:
3117         - 1
3118         - 1
3119     capabilities:
3120       feature_template_subint_Vlan_vmi_1:
3121         type: tosca.capabilities.Node
3122         occurrences:
3123         - 1
3124         - UNBOUNDED