1 tosca_definitions_version: tosca_simple_yaml_1_0_0
5 - openecomp_heat_index:
6 file: openecomp-heat/_index.yml
7 - GlobalSubstitutionTypes:
8 file: GlobalSubstitutionTypesServiceTemplate.yaml
12 label: vipr_atm_name_0
16 description: vipr_atm_name_0
22 description: network_name
28 description: port_name
40 description: fsb1-flavor
46 description: fsb1-flavor
48 cmaui_volume_test_compute_properties:
49 type: org.openecomp.resource.vfc.nodes.heat.cinder.Volume
54 - FSB1_availability_zone
74 - FSB1_flavor_update_policy
82 - FSB1_image_update_policy
102 - FSB1_reservation_id
106 - FSB1_scheduler_hints
107 delete_on_termination:
110 - FSB1_security_groups
114 - FSB1_software_config_transport
118 - FSB1_user_data_format
122 - FSB1_user_data_update_policy
147 cmaui_volume_test_neutron_port_properties:
148 type: org.openecomp.resource.vfc.nodes.heat.cinder.Volume
153 - FSB1_FSB1_Port_ip_address
157 - FSB1_FSB1_Port_network
161 - FSB1_FSB1_Port_admin_state_up
165 - FSB1_FSB1_Port_allowed_address_pairs
169 - FSB1_FSB1_Port_binding:vnic_type
173 - FSB1_FSB1_Port_device_id
177 - FSB1_FSB1_Port_device_owner
181 - FSB1_FSB1_Port_fixed_ips
185 - FSB1_FSB1_Port_name
189 - FSB1_FSB1_Port_port_security_enabled
193 - FSB1_FSB1_Port_qos_policy
197 - FSB1_FSB1_Port_security_groups
198 delete_on_termination:
201 - FSB1_FSB1_Port_value_specs
205 - FSB1_FSB1_Port_replacement_policy
209 - FSB1_FSB1_Port_show
213 - FSB1_FSB1_Port_subnets
217 - FSB1_FSB1_Port_tenant_id
218 cmaui_volume_test_contrailv2_VMI_properties:
219 type: org.openecomp.resource.vfc.nodes.heat.cinder.Volume
224 - FSB1_VMI_virtual_machine_interface_mac_addresses
228 - FSB1_VMI_virtual_network_refs
232 - FSB1_VMI_port_tuple_refs
236 - FSB1_VMI_security_group_refs
240 - FSB1_VMI_virtual_machine_interface_properties
248 - FSB1_VMI_virtual_machine_interface_allowed_address_pairs
258 type: org.openecomp.resource.abstract.nodes.FSB1
262 port_VMI_subinterface_indicator:
264 port_FSB1_Port_network:
267 get_input: fsb1-flavor
268 port_FSB1_Port_mac_address:
269 get_input: fsb1-Internal1-mac
270 port_FSB1_Port_subinterface_indicator:
272 compute_FSB1_availability_zone:
273 - get_input: fsb_zone
274 port_VMI_port_tuple_refs:
275 - - get_input: port_name
278 template: VM_NAME_PORT_3
281 get_input: vipr_atm_name_0
282 port_VMI_virtual_network_refs:
283 - - get_input: network_name
284 service_template_filter:
285 substitute_service_template: Nested_FSB1ServiceTemplate.yaml
290 - service_template_filter
294 type: org.openecomp.groups.heat.HeatStack
296 heat_file: ../Artifacts/ep-jsa_net.yaml
298 Version 2.0 02-09-2016 (Authors: Paul Phillips, pp2854 PROD)
300 - cmaui_volume_test_compute_properties
301 - cmaui_volume_test_neutron_port_properties
302 - cmaui_volume_test_contrailv2_VMI_properties
325 description: cgi fw01 left interface Mac-Address
336 - OS-EXT-IPS-MAC:mac_addr
338 description: cgi fw01 left interface Mac-Address
349 - OS-EXT-IPS-MAC:mac_addr