1 tosca_definitions_version: tosca_simple_yaml_1_0_0
3 template_name: GlobalSubstitutionTypes
5 - openecomp_heat_index:
6 file: openecomp-heat/_index.yml
8 org.openecomp.resource.abstract.nodes.heat.vdbe:
9 derived_from: org.openecomp.resource.abstract.nodes.VFC
13 description: Unique ID for this VF module inst
18 description: Reverse Path Filtering enable or disable for the fabric virtual network
23 description: Reverse Path Filtering enable or disable for the control virtual network
26 control_int_net_forwarding_mode:
28 description: forwarding mode of the control virtual network
33 description: Unique name for this VF instance
38 description: IPV4 address of the secondary vDBE VM on the VAN untrusted network
41 vdbe_aap_untrusted_ip_prefix_len:
43 description: ip prefix length for the primary vDBE VM on the VAN untrusted network
48 description: Number of vDBE subinterface virtual Networks
57 description: Unique Name for this VF module inst
62 description: Address mode for the vDBE cluster IP
65 control_int_net_shared:
67 description: control virtual network shared
70 vdbe_untrusted_v6_ip_1:
72 description: IPV6 address of the secondary vDBE VM on the VAN untrusted network
75 vdbe_untrusted_vmac_address:
77 description: Virtual MAC of the primary vDBE VM on the VAN untrusted network
80 control_int_net_flood_unknown_unicast:
82 description: forwarding mode of the control virtual network
85 port_vdbe_untr_1_port_network_role:
89 vdbe_aap_sec_untrusted_ip_prefix:
91 description: ip prefix for secondary vDBE VM aap on the VAN untrusted network
96 description: Unique ID for this VF inst
101 description: VM Name for this vdbe node 1
104 port_vdbe_untr_1_port_ip_requirements:
109 type: org.openecomp.datatypes.network.IpRequirements
112 description: The availability zone of secondary node1 vDBE vm in the local HA pair.
115 untrusted_vn_networks:
117 description: List of subinterface virtual networks
124 description: Image to use for vDBE
129 description: Name of NSDNet network from which the management IP addresses will be allocated
132 vdbe_aap_sec_untrusted_ip_prefix_len:
134 description: ip prefix length for the secondary DBE VM aap on the VAN untrusted network
137 port_vdbe_untr_1_port_mac_requirements:
138 type: org.openecomp.datatypes.network.MacRequirements
141 port_vdbe_untr_1_port_order:
145 vdbe_aap_untrusted_v6_ip_prefix:
147 description: ipv6 prefix for the primary vDBE VM on the VAN untrusted network
150 vdbe_aap_untrusted_v6_ip_prefix_len:
152 description: ipv6 prefix length for the primary vDBE VM on the VAN untrusted network
155 fabric_int_net_flood_unknown_unicast:
157 description: forwarding mode of the fabric virtual network
162 description: List of subinterface vlan tags
169 description: Flavor to use for vDBE
172 port_vdbe_untr_1_port_exCP_naming:
173 type: org.openecomp.datatypes.Naming
178 description: Counter.
181 port_vdbe_untr_1_port_subnetpoolid:
185 fabric_int_net_forwarding_mode:
187 description: forwarding mode of the fabric virtual network
190 fabric_int_net_shared:
191 description: fabric virtual network shared
196 description: Secondary MAC address of the secondary vDBE VM on the VAN untrusted network
201 description: Name of public untrusted network into which this vDBE HA cluster is deployed
204 port_vdbe_untr_1_port_network_role_tag:
210 description: VDBE device Name for this vdbe VNF
213 port_vdbe_untr_1_port_vlan_requirements:
218 type: org.openecomp.datatypes.network.VlanRequirements
219 vdbe_aap_untrusted_ip_prefix:
221 description: ip prefix for primary vDBE VM on the VAN untrusted network
227 description: output param connectivity
230 - dependency_vdbe_node_1:
231 capability: tosca.capabilities.Node
232 node: tosca.nodes.Root
233 relationship: tosca.relationships.DependsOn
237 - local_storage_vdbe_node_1:
238 capability: tosca.capabilities.Attachment
239 node: tosca.nodes.BlockStorage
240 relationship: tosca.relationships.AttachesTo
244 - dependency_fabric_int_net:
245 capability: tosca.capabilities.Node
246 node: tosca.nodes.Root
247 relationship: tosca.relationships.DependsOn
251 - dependency_vdbe_untr_1_port:
252 capability: tosca.capabilities.Node
253 node: tosca.nodes.Root
254 relationship: tosca.relationships.DependsOn
258 - dependency_vdbe_untr_1_subports:
259 capability: tosca.capabilities.Node
260 node: tosca.nodes.Root
261 relationship: tosca.relationships.DependsOn
265 - dependency_vdbe_untr_x_subport_vdbe_untr_1_subports:
266 capability: tosca.capabilities.Node
267 node: tosca.nodes.Root
268 relationship: tosca.relationships.DependsOn
272 - dependency_control_int_net:
273 capability: tosca.capabilities.Node
274 node: tosca.nodes.Root
275 relationship: tosca.relationships.DependsOn
280 disk.latency_vdbe_node_1:
281 type: org.openecomp.capabilities.metric.Ceilometer
282 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
287 type: tosca.capabilities.network.Bindable
291 network.outgoing.bytes.rate_vdbe_untr_1_port:
292 type: org.openecomp.capabilities.metric.Ceilometer
293 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
297 instance_vdbe_node_1:
298 type: org.openecomp.capabilities.metric.Ceilometer
299 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
303 forwarder_vdbe_untr_1_port:
304 type: org.openecomp.capabilities.Forwarder
308 disk.device.read.requests_vdbe_node_1:
309 type: org.openecomp.capabilities.metric.Ceilometer
310 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
314 end_point_fabric_int_net:
315 type: tosca.capabilities.Endpoint
319 disk.device.usage_vdbe_node_1:
320 type: org.openecomp.capabilities.metric.Ceilometer
321 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
325 attachment_fabric_int_net:
326 type: tosca.capabilities.Attachment
330 disk.write.bytes_vdbe_node_1:
331 type: org.openecomp.capabilities.metric.Ceilometer
332 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
336 disk.device.write.bytes_vdbe_node_1:
337 type: org.openecomp.capabilities.metric.Ceilometer
338 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
342 disk.allocation_vdbe_node_1:
343 type: org.openecomp.capabilities.metric.Ceilometer
344 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
349 type: org.openecomp.capabilities.metric.Ceilometer
350 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
354 cpu_util_vdbe_node_1:
355 type: org.openecomp.capabilities.metric.Ceilometer
356 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
360 network.incoming.packets.rate_vdbe_untr_1_port:
361 type: org.openecomp.capabilities.metric.Ceilometer
362 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
366 disk.device.read.bytes_vdbe_node_1:
367 type: org.openecomp.capabilities.metric.Ceilometer
368 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
372 disk.device.read.bytes.rate_vdbe_node_1:
373 type: org.openecomp.capabilities.metric.Ceilometer
374 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
378 disk.device.allocation_vdbe_node_1:
379 type: org.openecomp.capabilities.metric.Ceilometer
380 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
384 disk.write.requests.rate_vdbe_node_1:
385 type: org.openecomp.capabilities.metric.Ceilometer
386 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
390 disk.root.size_vdbe_node_1:
391 type: org.openecomp.capabilities.metric.Ceilometer
392 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
396 disk.device.iops_vdbe_node_1:
397 type: org.openecomp.capabilities.metric.Ceilometer
398 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
402 disk.device.write.requests_vdbe_node_1:
403 type: org.openecomp.capabilities.metric.Ceilometer
404 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
408 disk.write.requests_vdbe_node_1:
409 type: org.openecomp.capabilities.metric.Ceilometer
410 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
414 network.incoming.bytes.rate_vdbe_untr_1_port:
415 type: org.openecomp.capabilities.metric.Ceilometer
416 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
421 type: org.openecomp.capabilities.metric.Ceilometer
422 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
426 binding_vdbe_untr_1_port:
427 type: tosca.capabilities.network.Bindable
429 - org.openecomp.resource.cp.nodes.heat.network.contrailV2.VLANSubInterface
430 - org.openecomp.resource.cp.nodes.heat.network.v2.contrailV2.VLANSubInterface
434 disk.ephemeral.size_vdbe_node_1:
435 type: org.openecomp.capabilities.metric.Ceilometer
436 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
440 network.outgoing.bytes_vdbe_untr_1_port:
441 type: org.openecomp.capabilities.metric.Ceilometer
442 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
446 feature_vdbe_untr_1_subports:
447 type: tosca.capabilities.Node
451 disk.device.latency_vdbe_node_1:
452 type: org.openecomp.capabilities.metric.Ceilometer
453 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
457 disk.capacity_vdbe_node_1:
458 type: org.openecomp.capabilities.metric.Ceilometer
459 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
463 disk.device.capacity_vdbe_node_1:
464 type: org.openecomp.capabilities.metric.Ceilometer
465 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
469 feature_fabric_int_net:
470 type: tosca.capabilities.Node
474 link_control_int_net:
475 type: tosca.capabilities.network.Linkable
479 network.incoming.bytes_vdbe_untr_1_port:
480 type: org.openecomp.capabilities.metric.Ceilometer
481 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
485 end_point_control_int_net:
486 type: tosca.capabilities.Endpoint
490 disk.usage_vdbe_node_1:
491 type: org.openecomp.capabilities.metric.Ceilometer
492 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
496 disk.read.bytes_vdbe_node_1:
497 type: org.openecomp.capabilities.metric.Ceilometer
498 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
502 feature_vdbe_untr_x_subport_vdbe_untr_1_subports:
503 type: tosca.capabilities.Node
507 disk.device.read.requests.rate_vdbe_node_1:
508 type: org.openecomp.capabilities.metric.Ceilometer
509 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
514 type: tosca.capabilities.Container
516 - tosca.nodes.SoftwareComponent
520 feature_control_int_net:
521 type: tosca.capabilities.Node
525 cpu.delta_vdbe_node_1:
526 type: org.openecomp.capabilities.metric.Ceilometer
527 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
531 network.incoming.packets_vdbe_untr_1_port:
532 type: org.openecomp.capabilities.metric.Ceilometer
533 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
537 scalable_vdbe_node_1:
538 type: tosca.capabilities.Scalable
543 type: tosca.capabilities.network.Linkable
547 disk.iops_vdbe_node_1:
548 type: org.openecomp.capabilities.metric.Ceilometer
549 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
554 type: tosca.capabilities.Node
558 memory.resident_vdbe_node_1:
559 type: org.openecomp.capabilities.metric.Ceilometer
560 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
564 endpoint_vdbe_node_1:
565 type: tosca.capabilities.Endpoint.Admin
569 network.outgoing.packets.rate_vdbe_untr_1_port:
570 type: org.openecomp.capabilities.metric.Ceilometer
571 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
576 type: tosca.capabilities.OperatingSystem
580 network.outpoing.packets_vdbe_untr_1_port:
581 type: org.openecomp.capabilities.metric.Ceilometer
582 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
586 disk.read.bytes.rate_vdbe_node_1:
587 type: org.openecomp.capabilities.metric.Ceilometer
588 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
592 disk.device.write.bytes.rate_vdbe_node_1:
593 type: org.openecomp.capabilities.metric.Ceilometer
594 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
598 attachment_control_int_net:
599 type: tosca.capabilities.Attachment
604 type: org.openecomp.capabilities.metric.Ceilometer
605 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
609 disk.device.write.requests.rate_vdbe_node_1:
610 type: org.openecomp.capabilities.metric.Ceilometer
611 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
615 disk.read.requests_vdbe_node_1:
616 type: org.openecomp.capabilities.metric.Ceilometer
617 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
621 disk.write.bytes.rate_vdbe_node_1:
622 type: org.openecomp.capabilities.metric.Ceilometer
623 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
627 feature_vdbe_untr_1_port:
628 type: tosca.capabilities.Node
632 memory.usage_vdbe_node_1:
633 type: org.openecomp.capabilities.metric.Ceilometer
634 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
638 org.openecomp.resource.abstract.nodes.heat.subinterface.nested_vlan:
639 derived_from: org.openecomp.resource.abstract.nodes.AbstractSubstitute
641 aap_untrusted_ip_prefix:
643 description: ip prefix for primary vDBE VM on the VAN untrusted network
646 aap_sec_untrusted_ip_prefix:
648 description: ip prefix for secondary vDBE VM aap on the VAN untrusted network
651 vdbe_subport_network:
653 description: List of Contrail VLAN networks to use for the subinterfaces. The order and number of these must match the VLAN ID list
658 description: IPv6 address associated with subinterfaces
663 description: Index of instance among multiple instances. Use to retrieve correct parameter for this instance when passed all parameters for all instances.
666 subinterfaces_name_prefix:
668 description: Combined with subinterface_instance_index, this is used as the name of the subinterface resource
673 description: IPv4 address associated with subinterfaces
678 description: Address mode for the vDBE cluster IP
681 aap_untrusted_v6_ip_prefix:
683 description: ipv6 prefix for the primary vDBE VM on the VAN untrusted network
688 description: Parent Contrail interface
693 description: HW MAC address to use for subinterface
698 description: List of VLAN IDs to use for subinterfaces
703 aap_sec_untrusted_ip_prefix_len:
705 description: ip prefix length for the secondary DBE VM aap on the VAN untrusted network
710 description: virtual MAC address to use for subinterface
713 aap_untrusted_v6_ip_prefix_len:
715 description: ipv6 prefix length for the primary vDBE VM on the VAN untrusted network
718 aap_untrusted_ip_prefix_len:
720 description: ip prefix length for the primary vDBE VM on the VAN untrusted network
724 - dependency_vdbe_untr_x_subport:
725 capability: tosca.capabilities.Node
726 node: tosca.nodes.Root
727 relationship: tosca.relationships.DependsOn
731 - subinterface_link_vdbe_untr_x_subport:
732 capability: tosca.capabilities.network.Linkable
733 relationship: tosca.relationships.network.LinksTo
737 - binding_vdbe_untr_x_subport:
738 capability: tosca.capabilities.network.Bindable
739 node: org.openecomp.resource.cp.nodes.network.Port
740 relationship: tosca.relationships.network.BindsTo
745 feature_vdbe_untr_x_subport:
746 type: tosca.capabilities.Node