1 tosca_definitions_version: tosca_simple_yaml_1_0_0
3 template_name: GlobalSubstitutionTypes
5 - openecomp_heat_index:
6 file: openecomp-heat/_index.yml
8 org.openecomp.resource.abstract.nodes.heat.nested_pattern5:
9 derived_from: org.openecomp.resource.abstract.nodes.AbstractSubstitute
13 description: port network
18 description: Flavor for PD server
25 packet_external_network_name:
27 description: network name
30 packet_internal_network_name:
32 description: network name
37 description: PD server names
44 description: CMAUI1, CMAUI2 server names
51 description: availabilityzone name
56 description: sub interface network
61 description: PD Image server
69 - dependency_server_1b_pd_0:
70 capability: tosca.capabilities.Node
71 node: tosca.nodes.Root
72 relationship: tosca.relationships.DependsOn
76 - local_storage_server_1b_pd_0:
77 capability: tosca.capabilities.Attachment
78 node: tosca.nodes.BlockStorage
79 relationship: tosca.relationships.AttachesTo
83 - dependency_packet_external_network:
84 capability: tosca.capabilities.Node
85 node: tosca.nodes.Root
86 relationship: tosca.relationships.DependsOn
90 - dependency_pd_server_1b_port_0:
91 capability: tosca.capabilities.Node
92 node: tosca.nodes.Root
93 relationship: tosca.relationships.DependsOn
97 - dependency_test_resourceGroup_0:
98 capability: tosca.capabilities.Node
99 node: tosca.nodes.Root
100 relationship: tosca.relationships.DependsOn
104 - dependency_template_Vlan_vmi_1_test_resourceGroup_0:
105 capability: tosca.capabilities.Node
106 node: tosca.nodes.Root
107 relationship: tosca.relationships.DependsOn
111 - dependency_packet_internal_network:
112 capability: tosca.capabilities.Node
113 node: tosca.nodes.Root
114 relationship: tosca.relationships.DependsOn
118 - dependency_test_nested_level2:
119 capability: tosca.capabilities.Node
120 node: tosca.nodes.Root
121 relationship: tosca.relationships.DependsOn
125 - dependency_server_1b_ps_1_test_nested_level2:
126 capability: tosca.capabilities.Node
127 node: tosca.nodes.Root
128 relationship: tosca.relationships.DependsOn
132 - local_storage_server_1b_ps_1_test_nested_level2:
133 capability: tosca.capabilities.Attachment
134 node: tosca.nodes.BlockStorage
135 relationship: tosca.relationships.AttachesTo
139 - dependency_test_resourceGroup_1_test_nested_level2:
140 capability: tosca.capabilities.Node
141 node: tosca.nodes.Root
142 relationship: tosca.relationships.DependsOn
146 - dependency_template_Vlan_vmi_1_test_resourceGroup_1_test_nested_level2:
147 capability: tosca.capabilities.Node
148 node: tosca.nodes.Root
149 relationship: tosca.relationships.DependsOn
153 - dependency_test_resourceGroup_2_test_nested_level2:
154 capability: tosca.capabilities.Node
155 node: tosca.nodes.Root
156 relationship: tosca.relationships.DependsOn
160 - dependency_template_Vlan_vmi_1_test_resourceGroup_2_test_nested_level2:
161 capability: tosca.capabilities.Node
162 node: tosca.nodes.Root
163 relationship: tosca.relationships.DependsOn
167 - dependency_ps_server_1b_port_1_test_nested_level2:
168 capability: tosca.capabilities.Node
169 node: tosca.nodes.Root
170 relationship: tosca.relationships.DependsOn
174 - dependency_ps_server_1b_port_2_test_nested_level2:
175 capability: tosca.capabilities.Node
176 node: tosca.nodes.Root
177 relationship: tosca.relationships.DependsOn
181 - dependency_packet_ext_network_test_nested_level2:
182 capability: tosca.capabilities.Node
183 node: tosca.nodes.Root
184 relationship: tosca.relationships.DependsOn
188 - dependency_packet_int_network_test_nested_level2:
189 capability: tosca.capabilities.Node
190 node: tosca.nodes.Root
191 relationship: tosca.relationships.DependsOn
195 - dependency_server_1b_ps_2_test_nested_level2:
196 capability: tosca.capabilities.Node
197 node: tosca.nodes.Root
198 relationship: tosca.relationships.DependsOn
202 - local_storage_server_1b_ps_2_test_nested_level2:
203 capability: tosca.capabilities.Attachment
204 node: tosca.nodes.BlockStorage
205 relationship: tosca.relationships.AttachesTo
210 disk.device.write.bytes.rate_server_1b_ps_1_test_nested_level2:
211 type: org.openecomp.capabilities.metric.Ceilometer
212 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
216 network.outgoing.packets.rate_ps_server_1b_port_2_test_nested_level2:
217 type: org.openecomp.capabilities.metric.Ceilometer
218 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
222 scalable_server_1b_ps_1_test_nested_level2:
223 type: tosca.capabilities.Scalable
227 end_point_packet_ext_network_test_nested_level2:
228 type: tosca.capabilities.Endpoint
232 disk.capacity_server_1b_ps_2_test_nested_level2:
233 type: org.openecomp.capabilities.metric.Ceilometer
234 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
238 disk.device.latency_server_1b_ps_2_test_nested_level2:
239 type: org.openecomp.capabilities.metric.Ceilometer
240 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
244 disk.device.write.bytes_server_1b_ps_2_test_nested_level2:
245 type: org.openecomp.capabilities.metric.Ceilometer
246 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
250 disk.device.write.requests_server_1b_pd_0:
251 type: org.openecomp.capabilities.metric.Ceilometer
252 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
256 disk.read.requests_server_1b_ps_2_test_nested_level2:
257 type: org.openecomp.capabilities.metric.Ceilometer
258 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
262 endpoint_server_1b_ps_2_test_nested_level2:
263 type: tosca.capabilities.Endpoint.Admin
267 disk.iops_server_1b_ps_2_test_nested_level2:
268 type: org.openecomp.capabilities.metric.Ceilometer
269 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
273 disk.device.read.bytes_server_1b_ps_1_test_nested_level2:
274 type: org.openecomp.capabilities.metric.Ceilometer
275 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
279 feature_packet_ext_network_test_nested_level2:
280 type: tosca.capabilities.Node
284 forwarder_ps_server_1b_port_1_test_nested_level2:
285 type: org.openecomp.capabilities.Forwarder
289 forwarder_pd_server_1b_port_0:
290 type: org.openecomp.capabilities.Forwarder
294 disk.capacity_server_1b_pd_0:
295 type: org.openecomp.capabilities.metric.Ceilometer
296 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
300 network.outpoing.packets_pd_server_1b_port_0:
301 type: org.openecomp.capabilities.metric.Ceilometer
302 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
306 cpu_util_server_1b_ps_2_test_nested_level2:
307 type: org.openecomp.capabilities.metric.Ceilometer
308 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
312 network.incoming.packets_ps_server_1b_port_1_test_nested_level2:
313 type: org.openecomp.capabilities.metric.Ceilometer
314 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
318 feature_pd_server_1b_port_0:
319 type: tosca.capabilities.Node
323 memory_server_1b_ps_1_test_nested_level2:
324 type: org.openecomp.capabilities.metric.Ceilometer
325 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
329 link_packet_int_network_test_nested_level2:
330 type: tosca.capabilities.network.Linkable
334 os_server_1b_ps_1_test_nested_level2:
335 type: tosca.capabilities.OperatingSystem
339 network.incoming.bytes_ps_server_1b_port_2_test_nested_level2:
340 type: org.openecomp.capabilities.metric.Ceilometer
341 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
345 disk.root.size_server_1b_ps_1_test_nested_level2:
346 type: org.openecomp.capabilities.metric.Ceilometer
347 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
351 attachment_packet_internal_network:
352 type: tosca.capabilities.Attachment
356 disk.device.allocation_server_1b_pd_0:
357 type: org.openecomp.capabilities.metric.Ceilometer
358 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
362 feature_test_resourceGroup_0:
363 type: tosca.capabilities.Node
367 feature_packet_int_network_test_nested_level2:
368 type: tosca.capabilities.Node
372 disk.write.requests_server_1b_ps_1_test_nested_level2:
373 type: org.openecomp.capabilities.metric.Ceilometer
374 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
379 type: org.openecomp.capabilities.metric.Ceilometer
380 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
384 disk.write.requests.rate_server_1b_pd_0:
385 type: org.openecomp.capabilities.metric.Ceilometer
386 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
390 network.incoming.bytes.rate_ps_server_1b_port_2_test_nested_level2:
391 type: org.openecomp.capabilities.metric.Ceilometer
392 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
396 disk.latency_server_1b_ps_1_test_nested_level2:
397 type: org.openecomp.capabilities.metric.Ceilometer
398 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
402 disk.device.read.bytes.rate_server_1b_pd_0:
403 type: org.openecomp.capabilities.metric.Ceilometer
404 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
408 feature_test_nested_level2:
409 type: tosca.capabilities.Node
413 disk.write.bytes.rate_server_1b_pd_0:
414 type: org.openecomp.capabilities.metric.Ceilometer
415 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
419 disk.device.usage_server_1b_ps_1_test_nested_level2:
420 type: org.openecomp.capabilities.metric.Ceilometer
421 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
425 disk.device.read.requests.rate_server_1b_ps_2_test_nested_level2:
426 type: org.openecomp.capabilities.metric.Ceilometer
427 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
431 disk.read.bytes_server_1b_ps_1_test_nested_level2:
432 type: org.openecomp.capabilities.metric.Ceilometer
433 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
437 disk.read.bytes_server_1b_ps_2_test_nested_level2:
438 type: org.openecomp.capabilities.metric.Ceilometer
439 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
443 cpu_server_1b_ps_1_test_nested_level2:
444 type: org.openecomp.capabilities.metric.Ceilometer
445 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
449 disk.usage_server_1b_pd_0:
450 type: org.openecomp.capabilities.metric.Ceilometer
451 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
455 disk.ephemeral.size_server_1b_ps_2_test_nested_level2:
456 type: org.openecomp.capabilities.metric.Ceilometer
457 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
461 end_point_packet_int_network_test_nested_level2:
462 type: tosca.capabilities.Endpoint
466 disk.device.iops_server_1b_pd_0:
467 type: org.openecomp.capabilities.metric.Ceilometer
468 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
472 disk.write.bytes.rate_server_1b_ps_1_test_nested_level2:
473 type: org.openecomp.capabilities.metric.Ceilometer
474 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
478 scalable_server_1b_ps_2_test_nested_level2:
479 type: tosca.capabilities.Scalable
483 cpu_util_server_1b_pd_0:
484 type: org.openecomp.capabilities.metric.Ceilometer
485 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
489 disk.read.requests_server_1b_pd_0:
490 type: org.openecomp.capabilities.metric.Ceilometer
491 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
495 disk.device.write.bytes.rate_server_1b_pd_0:
496 type: org.openecomp.capabilities.metric.Ceilometer
497 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
501 vcpus_server_1b_ps_1_test_nested_level2:
502 type: org.openecomp.capabilities.metric.Ceilometer
503 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
507 disk.device.write.bytes_server_1b_ps_1_test_nested_level2:
508 type: org.openecomp.capabilities.metric.Ceilometer
509 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
513 feature_server_1b_ps_2_test_nested_level2:
514 type: tosca.capabilities.Node
518 disk.iops_server_1b_ps_1_test_nested_level2:
519 type: org.openecomp.capabilities.metric.Ceilometer
520 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
524 disk.device.read.bytes_server_1b_ps_2_test_nested_level2:
525 type: org.openecomp.capabilities.metric.Ceilometer
526 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
530 feature_server_1b_pd_0:
531 type: tosca.capabilities.Node
535 disk.device.write.requests.rate_server_1b_ps_2_test_nested_level2:
536 type: org.openecomp.capabilities.metric.Ceilometer
537 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
541 disk.device.write.requests_server_1b_ps_2_test_nested_level2:
542 type: org.openecomp.capabilities.metric.Ceilometer
543 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
547 disk.capacity_server_1b_ps_1_test_nested_level2:
548 type: org.openecomp.capabilities.metric.Ceilometer
549 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
553 feature_ps_server_1b_port_2_test_nested_level2:
554 type: tosca.capabilities.Node
558 disk.allocation_server_1b_ps_1_test_nested_level2:
559 type: org.openecomp.capabilities.metric.Ceilometer
560 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
564 network.outgoing.bytes_ps_server_1b_port_2_test_nested_level2:
565 type: org.openecomp.capabilities.metric.Ceilometer
566 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
570 endpoint_server_1b_ps_1_test_nested_level2:
571 type: tosca.capabilities.Endpoint.Admin
575 disk.usage_server_1b_ps_1_test_nested_level2:
576 type: org.openecomp.capabilities.metric.Ceilometer
577 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
581 disk.device.write.bytes_server_1b_pd_0:
582 type: org.openecomp.capabilities.metric.Ceilometer
583 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
587 disk.iops_server_1b_pd_0:
588 type: org.openecomp.capabilities.metric.Ceilometer
589 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
593 feature_template_Vlan_vmi_1_test_resourceGroup_0:
594 type: tosca.capabilities.Node
598 end_point_packet_external_network:
599 type: tosca.capabilities.Endpoint
603 forwarder_ps_server_1b_port_2_test_nested_level2:
604 type: org.openecomp.capabilities.Forwarder
608 disk.write.bytes_server_1b_pd_0:
609 type: org.openecomp.capabilities.metric.Ceilometer
610 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
614 cpu.delta_server_1b_ps_2_test_nested_level2:
615 type: org.openecomp.capabilities.metric.Ceilometer
616 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
620 instance_server_1b_ps_2_test_nested_level2:
621 type: org.openecomp.capabilities.metric.Ceilometer
622 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
626 disk.device.capacity_server_1b_ps_2_test_nested_level2:
627 type: org.openecomp.capabilities.metric.Ceilometer
628 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
632 binding_server_1b_pd_0:
633 type: tosca.capabilities.network.Bindable
637 disk.device.read.requests_server_1b_ps_2_test_nested_level2:
638 type: org.openecomp.capabilities.metric.Ceilometer
639 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
643 disk.device.write.requests.rate_server_1b_pd_0:
644 type: org.openecomp.capabilities.metric.Ceilometer
645 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
649 disk.device.iops_server_1b_ps_2_test_nested_level2:
650 type: org.openecomp.capabilities.metric.Ceilometer
651 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
655 feature_template_Vlan_vmi_1_test_resourceGroup_2_test_nested_level2:
656 type: tosca.capabilities.Node
660 feature_template_Vlan_vmi_1_test_resourceGroup_1_test_nested_level2:
661 type: tosca.capabilities.Node
665 network.outgoing.bytes_pd_server_1b_port_0:
666 type: org.openecomp.capabilities.metric.Ceilometer
667 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
671 disk.read.requests_server_1b_ps_1_test_nested_level2:
672 type: org.openecomp.capabilities.metric.Ceilometer
673 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
677 memory.usage_server_1b_ps_1_test_nested_level2:
678 type: org.openecomp.capabilities.metric.Ceilometer
679 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
683 link_packet_external_network:
684 type: tosca.capabilities.network.Linkable
688 memory.usage_server_1b_ps_2_test_nested_level2:
689 type: org.openecomp.capabilities.metric.Ceilometer
690 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
694 disk.device.iops_server_1b_ps_1_test_nested_level2:
695 type: org.openecomp.capabilities.metric.Ceilometer
696 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
700 memory.resident_server_1b_pd_0:
701 type: org.openecomp.capabilities.metric.Ceilometer
702 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
706 network.outgoing.packets.rate_pd_server_1b_port_0:
707 type: org.openecomp.capabilities.metric.Ceilometer
708 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
712 disk.device.read.bytes_server_1b_pd_0:
713 type: org.openecomp.capabilities.metric.Ceilometer
714 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
718 feature_server_1b_ps_1_test_nested_level2:
719 type: tosca.capabilities.Node
723 vcpus_server_1b_ps_2_test_nested_level2:
724 type: org.openecomp.capabilities.metric.Ceilometer
725 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
729 attachment_pd_server_1b_port_0:
730 type: tosca.capabilities.Attachment
734 attachment_packet_ext_network_test_nested_level2:
735 type: tosca.capabilities.Attachment
739 disk.device.write.requests.rate_server_1b_ps_1_test_nested_level2:
740 type: org.openecomp.capabilities.metric.Ceilometer
741 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
745 host_server_1b_ps_1_test_nested_level2:
746 type: tosca.capabilities.Container
748 - tosca.nodes.SoftwareComponent
752 disk.ephemeral.size_server_1b_pd_0:
753 type: org.openecomp.capabilities.metric.Ceilometer
754 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
758 network.outgoing.bytes_ps_server_1b_port_1_test_nested_level2:
759 type: org.openecomp.capabilities.metric.Ceilometer
760 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
764 disk.write.bytes_server_1b_ps_1_test_nested_level2:
765 type: org.openecomp.capabilities.metric.Ceilometer
766 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
770 end_point_packet_internal_network:
771 type: tosca.capabilities.Endpoint
775 attachment_ps_server_1b_port_1_test_nested_level2:
776 type: tosca.capabilities.Attachment
780 feature_ps_server_1b_port_1_test_nested_level2:
781 type: tosca.capabilities.Node
785 feature_packet_internal_network:
786 type: tosca.capabilities.Node
790 cpu.delta_server_1b_ps_1_test_nested_level2:
791 type: org.openecomp.capabilities.metric.Ceilometer
792 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
796 disk.device.write.requests_server_1b_ps_1_test_nested_level2:
797 type: org.openecomp.capabilities.metric.Ceilometer
798 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
802 disk.device.capacity_server_1b_ps_1_test_nested_level2:
803 type: org.openecomp.capabilities.metric.Ceilometer
804 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
808 disk.usage_server_1b_ps_2_test_nested_level2:
809 type: org.openecomp.capabilities.metric.Ceilometer
810 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
814 instance_server_1b_pd_0:
815 type: org.openecomp.capabilities.metric.Ceilometer
816 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
820 disk.device.capacity_server_1b_pd_0:
821 type: org.openecomp.capabilities.metric.Ceilometer
822 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
826 disk.root.size_server_1b_ps_2_test_nested_level2:
827 type: org.openecomp.capabilities.metric.Ceilometer
828 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
832 disk.device.read.bytes.rate_server_1b_ps_1_test_nested_level2:
833 type: org.openecomp.capabilities.metric.Ceilometer
834 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
838 instance_server_1b_ps_1_test_nested_level2:
839 type: org.openecomp.capabilities.metric.Ceilometer
840 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
844 network.outgoing.bytes.rate_ps_server_1b_port_1_test_nested_level2:
845 type: org.openecomp.capabilities.metric.Ceilometer
846 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
850 network.incoming.packets.rate_ps_server_1b_port_1_test_nested_level2:
851 type: org.openecomp.capabilities.metric.Ceilometer
852 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
856 disk.device.read.requests_server_1b_ps_1_test_nested_level2:
857 type: org.openecomp.capabilities.metric.Ceilometer
858 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
862 network.outgoing.bytes.rate_pd_server_1b_port_0:
863 type: org.openecomp.capabilities.metric.Ceilometer
864 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
868 network.incoming.packets.rate_pd_server_1b_port_0:
869 type: org.openecomp.capabilities.metric.Ceilometer
870 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
874 network.incoming.packets_ps_server_1b_port_2_test_nested_level2:
875 type: org.openecomp.capabilities.metric.Ceilometer
876 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
881 type: tosca.capabilities.OperatingSystem
885 network.incoming.bytes_ps_server_1b_port_1_test_nested_level2:
886 type: org.openecomp.capabilities.metric.Ceilometer
887 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
891 endpoint_server_1b_pd_0:
892 type: tosca.capabilities.Endpoint.Admin
896 disk.read.bytes_server_1b_pd_0:
897 type: org.openecomp.capabilities.metric.Ceilometer
898 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
902 cpu_util_server_1b_ps_1_test_nested_level2:
903 type: org.openecomp.capabilities.metric.Ceilometer
904 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
908 disk.write.requests_server_1b_ps_2_test_nested_level2:
909 type: org.openecomp.capabilities.metric.Ceilometer
910 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
914 disk.latency_server_1b_ps_2_test_nested_level2:
915 type: org.openecomp.capabilities.metric.Ceilometer
916 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
920 binding_server_1b_ps_1_test_nested_level2:
921 type: tosca.capabilities.network.Bindable
925 disk.device.usage_server_1b_ps_2_test_nested_level2:
926 type: org.openecomp.capabilities.metric.Ceilometer
927 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
931 network.incoming.bytes.rate_ps_server_1b_port_1_test_nested_level2:
932 type: org.openecomp.capabilities.metric.Ceilometer
933 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
937 binding_ps_server_1b_port_1_test_nested_level2:
938 type: tosca.capabilities.network.Bindable
940 - org.openecomp.resource.cp.nodes.heat.network.contrailV2.VLANSubInterface
945 type: tosca.capabilities.Container
947 - tosca.nodes.SoftwareComponent
951 attachment_packet_int_network_test_nested_level2:
952 type: tosca.capabilities.Attachment
956 network.incoming.bytes_pd_server_1b_port_0:
957 type: org.openecomp.capabilities.metric.Ceilometer
958 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
962 disk.root.size_server_1b_pd_0:
963 type: org.openecomp.capabilities.metric.Ceilometer
964 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
968 binding_ps_server_1b_port_2_test_nested_level2:
969 type: tosca.capabilities.network.Bindable
971 - org.openecomp.resource.cp.nodes.heat.network.contrailV2.VLANSubInterface
975 disk.ephemeral.size_server_1b_ps_1_test_nested_level2:
976 type: org.openecomp.capabilities.metric.Ceilometer
977 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
981 disk.allocation_server_1b_ps_2_test_nested_level2:
982 type: org.openecomp.capabilities.metric.Ceilometer
983 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
987 memory_server_1b_pd_0:
988 type: org.openecomp.capabilities.metric.Ceilometer
989 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
993 disk.device.latency_server_1b_pd_0:
994 type: org.openecomp.capabilities.metric.Ceilometer
995 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
999 binding_server_1b_ps_2_test_nested_level2:
1000 type: tosca.capabilities.network.Bindable
1004 disk.device.read.requests.rate_server_1b_ps_1_test_nested_level2:
1005 type: org.openecomp.capabilities.metric.Ceilometer
1006 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1010 disk.device.usage_server_1b_pd_0:
1011 type: org.openecomp.capabilities.metric.Ceilometer
1012 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1016 cpu_server_1b_ps_2_test_nested_level2:
1017 type: org.openecomp.capabilities.metric.Ceilometer
1018 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1022 feature_packet_external_network:
1023 type: tosca.capabilities.Node
1027 memory.resident_server_1b_ps_2_test_nested_level2:
1028 type: org.openecomp.capabilities.metric.Ceilometer
1029 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1033 memory.resident_server_1b_ps_1_test_nested_level2:
1034 type: org.openecomp.capabilities.metric.Ceilometer
1035 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1039 disk.write.bytes.rate_server_1b_ps_2_test_nested_level2:
1040 type: org.openecomp.capabilities.metric.Ceilometer
1041 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1045 disk.device.write.bytes.rate_server_1b_ps_2_test_nested_level2:
1046 type: org.openecomp.capabilities.metric.Ceilometer
1047 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1051 network.outgoing.packets.rate_ps_server_1b_port_1_test_nested_level2:
1052 type: org.openecomp.capabilities.metric.Ceilometer
1053 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1057 disk.device.latency_server_1b_ps_1_test_nested_level2:
1058 type: org.openecomp.capabilities.metric.Ceilometer
1059 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1063 disk.allocation_server_1b_pd_0:
1064 type: org.openecomp.capabilities.metric.Ceilometer
1065 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1069 link_packet_ext_network_test_nested_level2:
1070 type: tosca.capabilities.network.Linkable
1074 disk.write.bytes_server_1b_ps_2_test_nested_level2:
1075 type: org.openecomp.capabilities.metric.Ceilometer
1076 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1080 binding_pd_server_1b_port_0:
1081 type: tosca.capabilities.network.Bindable
1083 - org.openecomp.resource.cp.nodes.heat.network.contrailV2.VLANSubInterface
1087 host_server_1b_ps_2_test_nested_level2:
1088 type: tosca.capabilities.Container
1090 - tosca.nodes.SoftwareComponent
1094 disk.device.read.requests.rate_server_1b_pd_0:
1095 type: org.openecomp.capabilities.metric.Ceilometer
1096 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1100 link_packet_internal_network:
1101 type: tosca.capabilities.network.Linkable
1105 network.incoming.packets.rate_ps_server_1b_port_2_test_nested_level2:
1106 type: org.openecomp.capabilities.metric.Ceilometer
1107 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1111 disk.write.requests_server_1b_pd_0:
1112 type: org.openecomp.capabilities.metric.Ceilometer
1113 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1117 attachment_ps_server_1b_port_2_test_nested_level2:
1118 type: tosca.capabilities.Attachment
1122 disk.device.allocation_server_1b_ps_1_test_nested_level2:
1123 type: org.openecomp.capabilities.metric.Ceilometer
1124 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1128 disk.device.read.bytes.rate_server_1b_ps_2_test_nested_level2:
1129 type: org.openecomp.capabilities.metric.Ceilometer
1130 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1134 scalable_server_1b_pd_0:
1135 type: tosca.capabilities.Scalable
1139 memory_server_1b_ps_2_test_nested_level2:
1140 type: org.openecomp.capabilities.metric.Ceilometer
1141 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1145 network.outgoing.bytes.rate_ps_server_1b_port_2_test_nested_level2:
1146 type: org.openecomp.capabilities.metric.Ceilometer
1147 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1151 os_server_1b_ps_2_test_nested_level2:
1152 type: tosca.capabilities.OperatingSystem
1156 cpu.delta_server_1b_pd_0:
1157 type: org.openecomp.capabilities.metric.Ceilometer
1158 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1162 disk.read.bytes.rate_server_1b_ps_1_test_nested_level2:
1163 type: org.openecomp.capabilities.metric.Ceilometer
1164 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1168 feature_test_resourceGroup_1_test_nested_level2:
1169 type: tosca.capabilities.Node
1173 feature_test_resourceGroup_2_test_nested_level2:
1174 type: tosca.capabilities.Node
1178 disk.read.bytes.rate_server_1b_ps_2_test_nested_level2:
1179 type: org.openecomp.capabilities.metric.Ceilometer
1180 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1184 disk.device.allocation_server_1b_ps_2_test_nested_level2:
1185 type: org.openecomp.capabilities.metric.Ceilometer
1186 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1190 vcpus_server_1b_pd_0:
1191 type: org.openecomp.capabilities.metric.Ceilometer
1192 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1196 disk.device.read.requests_server_1b_pd_0:
1197 type: org.openecomp.capabilities.metric.Ceilometer
1198 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1202 network.incoming.packets_pd_server_1b_port_0:
1203 type: org.openecomp.capabilities.metric.Ceilometer
1204 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1208 disk.read.bytes.rate_server_1b_pd_0:
1209 type: org.openecomp.capabilities.metric.Ceilometer
1210 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1214 memory.usage_server_1b_pd_0:
1215 type: org.openecomp.capabilities.metric.Ceilometer
1216 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1220 attachment_packet_external_network:
1221 type: tosca.capabilities.Attachment
1225 network.outpoing.packets_ps_server_1b_port_1_test_nested_level2:
1226 type: org.openecomp.capabilities.metric.Ceilometer
1227 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1231 disk.latency_server_1b_pd_0:
1232 type: org.openecomp.capabilities.metric.Ceilometer
1233 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1237 network.outpoing.packets_ps_server_1b_port_2_test_nested_level2:
1238 type: org.openecomp.capabilities.metric.Ceilometer
1239 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1243 network.incoming.bytes.rate_pd_server_1b_port_0:
1244 type: org.openecomp.capabilities.metric.Ceilometer
1245 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1249 disk.write.requests.rate_server_1b_ps_2_test_nested_level2:
1250 type: org.openecomp.capabilities.metric.Ceilometer
1251 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1255 disk.write.requests.rate_server_1b_ps_1_test_nested_level2:
1256 type: org.openecomp.capabilities.metric.Ceilometer
1257 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1261 org.openecomp.resource.abstract.nodes.pd_server_1b:
1262 derived_from: org.openecomp.resource.abstract.nodes.VFC
1264 compute_pd_server_1b_name:
1272 description: Index value of this substitution service template runtime instance
1277 - greater_or_equal: 0
1282 port_pd_server_1b_port_vlan_requirements:
1287 type: org.openecomp.datatypes.network.VlanRequirements
1288 subinterface_nested_vlan_net1:
1294 port_pd_server_1b_port_network_role_tag:
1302 port_pd_server_1b_port_replacement_policy:
1308 port_pd_server_1b_port_mac_requirements:
1309 type: org.openecomp.datatypes.network.MacRequirements
1312 port_pd_server_1b_port_network_role:
1316 subinterface_nested_vlan_parent_interface:
1322 port_pd_server_1b_port_fixed_ips:
1327 type: org.openecomp.datatypes.heat.neutron.port.FixedIps
1328 port_pd_server_1b_port_network:
1334 compute_pd_server_1b_availability_zone:
1340 port_pd_server_1b_port_order:
1344 port_pd_server_1b_port_exCP_naming:
1345 type: org.openecomp.datatypes.Naming
1348 port_pd_server_1b_port_ip_requirements:
1353 type: org.openecomp.datatypes.network.IpRequirements
1354 port_pd_server_1b_port_subnetpoolid:
1359 - dependency_pd_server_1b_pd_server_1b_port_nested_vlan:
1360 capability: tosca.capabilities.Node
1361 node: tosca.nodes.Root
1362 relationship: tosca.relationships.DependsOn
1366 - dependency_template_Vlan_vmi_1_pd_server_1b_pd_server_1b_port_nested_vlan:
1367 capability: tosca.capabilities.Node
1368 node: tosca.nodes.Root
1369 relationship: tosca.relationships.DependsOn
1373 - link_template_Vlan_vmi_1_pd_server_1b_pd_server_1b_port_nested_vlan:
1374 capability: tosca.capabilities.network.Linkable
1375 relationship: tosca.relationships.network.LinksTo
1379 - dependency_pd_server_1b:
1380 capability: tosca.capabilities.Node
1381 node: tosca.nodes.Root
1382 relationship: tosca.relationships.DependsOn
1386 - local_storage_pd_server_1b:
1387 capability: tosca.capabilities.Attachment
1388 node: tosca.nodes.BlockStorage
1389 relationship: tosca.relationships.AttachesTo
1393 - dependency_pd_server_1b_pd_server_1b_port:
1394 capability: tosca.capabilities.Node
1395 node: tosca.nodes.Root
1396 relationship: tosca.relationships.DependsOn
1400 - link_pd_server_1b_pd_server_1b_port:
1401 capability: tosca.capabilities.network.Linkable
1402 relationship: tosca.relationships.network.LinksTo
1407 disk.device.read.bytes_pd_server_1b:
1408 type: org.openecomp.capabilities.metric.Ceilometer
1409 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1413 feature_pd_server_1b_pd_server_1b_port:
1414 type: tosca.capabilities.Node
1419 type: tosca.capabilities.Container
1421 - tosca.nodes.SoftwareComponent
1425 disk.read.bytes.rate_pd_server_1b:
1426 type: org.openecomp.capabilities.metric.Ceilometer
1427 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1431 disk.allocation_pd_server_1b:
1432 type: org.openecomp.capabilities.metric.Ceilometer
1433 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1437 network.incoming.bytes.rate_pd_server_1b_pd_server_1b_port:
1438 type: org.openecomp.capabilities.metric.Ceilometer
1439 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1443 cpu.delta_pd_server_1b:
1444 type: org.openecomp.capabilities.metric.Ceilometer
1445 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1449 forwarder_pd_server_1b_pd_server_1b_port:
1450 type: org.openecomp.capabilities.Forwarder
1454 network.incoming.bytes_pd_server_1b_pd_server_1b_port:
1455 type: org.openecomp.capabilities.metric.Ceilometer
1456 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1460 disk.device.read.requests_pd_server_1b:
1461 type: org.openecomp.capabilities.metric.Ceilometer
1462 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1466 feature_pd_server_1b:
1467 type: tosca.capabilities.Node
1471 disk.device.iops_pd_server_1b:
1472 type: org.openecomp.capabilities.metric.Ceilometer
1473 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1477 binding_pd_server_1b_pd_server_1b_port:
1478 type: tosca.capabilities.network.Bindable
1480 - org.openecomp.resource.cp.nodes.heat.network.contrailV2.VLANSubInterface
1485 type: org.openecomp.capabilities.metric.Ceilometer
1486 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1490 disk.write.bytes.rate_pd_server_1b:
1491 type: org.openecomp.capabilities.metric.Ceilometer
1492 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1496 disk.device.read.requests.rate_pd_server_1b:
1497 type: org.openecomp.capabilities.metric.Ceilometer
1498 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1502 endpoint_pd_server_1b:
1503 type: tosca.capabilities.Endpoint.Admin
1507 disk.device.allocation_pd_server_1b:
1508 type: org.openecomp.capabilities.metric.Ceilometer
1509 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1513 memory.usage_pd_server_1b:
1514 type: org.openecomp.capabilities.metric.Ceilometer
1515 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1519 network.outpoing.packets_pd_server_1b_pd_server_1b_port:
1520 type: org.openecomp.capabilities.metric.Ceilometer
1521 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1525 memory_pd_server_1b:
1526 type: org.openecomp.capabilities.metric.Ceilometer
1527 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1531 disk.device.read.bytes.rate_pd_server_1b:
1532 type: org.openecomp.capabilities.metric.Ceilometer
1533 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1537 disk.device.latency_pd_server_1b:
1538 type: org.openecomp.capabilities.metric.Ceilometer
1539 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1543 disk.read.bytes_pd_server_1b:
1544 type: org.openecomp.capabilities.metric.Ceilometer
1545 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1549 disk.device.usage_pd_server_1b:
1550 type: org.openecomp.capabilities.metric.Ceilometer
1551 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1555 attachment_pd_server_1b_pd_server_1b_port:
1556 type: tosca.capabilities.Attachment
1560 disk.device.write.requests_pd_server_1b:
1561 type: org.openecomp.capabilities.metric.Ceilometer
1562 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1566 disk.latency_pd_server_1b:
1567 type: org.openecomp.capabilities.metric.Ceilometer
1568 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1572 disk.ephemeral.size_pd_server_1b:
1573 type: org.openecomp.capabilities.metric.Ceilometer
1574 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1578 network.outgoing.bytes.rate_pd_server_1b_pd_server_1b_port:
1579 type: org.openecomp.capabilities.metric.Ceilometer
1580 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1584 scalable_pd_server_1b:
1585 type: tosca.capabilities.Scalable
1589 disk.write.requests_pd_server_1b:
1590 type: org.openecomp.capabilities.metric.Ceilometer
1591 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1595 feature_template_Vlan_vmi_1_pd_server_1b_pd_server_1b_port_nested_vlan:
1596 type: tosca.capabilities.Node
1600 disk.device.write.bytes.rate_pd_server_1b:
1601 type: org.openecomp.capabilities.metric.Ceilometer
1602 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1606 disk.root.size_pd_server_1b:
1607 type: org.openecomp.capabilities.metric.Ceilometer
1608 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1612 disk.iops_pd_server_1b:
1613 type: org.openecomp.capabilities.metric.Ceilometer
1614 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1618 disk.write.bytes_pd_server_1b:
1619 type: org.openecomp.capabilities.metric.Ceilometer
1620 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1624 disk.device.write.bytes_pd_server_1b:
1625 type: org.openecomp.capabilities.metric.Ceilometer
1626 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1631 type: tosca.capabilities.OperatingSystem
1636 type: org.openecomp.capabilities.metric.Ceilometer
1637 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1641 network.incoming.packets.rate_pd_server_1b_pd_server_1b_port:
1642 type: org.openecomp.capabilities.metric.Ceilometer
1643 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1647 instance_pd_server_1b:
1648 type: org.openecomp.capabilities.metric.Ceilometer
1649 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1653 binding_pd_server_1b:
1654 type: tosca.capabilities.network.Bindable
1658 cpu_util_pd_server_1b:
1659 type: org.openecomp.capabilities.metric.Ceilometer
1660 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1664 network.outgoing.bytes_pd_server_1b_pd_server_1b_port:
1665 type: org.openecomp.capabilities.metric.Ceilometer
1666 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1670 memory.resident_pd_server_1b:
1671 type: org.openecomp.capabilities.metric.Ceilometer
1672 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1676 feature_pd_server_1b_pd_server_1b_port_nested_vlan:
1677 type: tosca.capabilities.Node
1681 network.incoming.packets_pd_server_1b_pd_server_1b_port:
1682 type: org.openecomp.capabilities.metric.Ceilometer
1683 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1687 disk.device.write.requests.rate_pd_server_1b:
1688 type: org.openecomp.capabilities.metric.Ceilometer
1689 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1693 disk.device.capacity_pd_server_1b:
1694 type: org.openecomp.capabilities.metric.Ceilometer
1695 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1699 disk.read.requests_pd_server_1b:
1700 type: org.openecomp.capabilities.metric.Ceilometer
1701 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1705 network.outgoing.packets.rate_pd_server_1b_pd_server_1b_port:
1706 type: org.openecomp.capabilities.metric.Ceilometer
1707 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1711 disk.capacity_pd_server_1b:
1712 type: org.openecomp.capabilities.metric.Ceilometer
1713 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1717 disk.usage_pd_server_1b:
1718 type: org.openecomp.capabilities.metric.Ceilometer
1719 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1723 disk.write.requests.rate_pd_server_1b:
1724 type: org.openecomp.capabilities.metric.Ceilometer
1725 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1729 org.openecomp.resource.abstract.nodes.heat.nested_pattern5_levelTwo:
1730 derived_from: org.openecomp.resource.abstract.nodes.AbstractSubstitute
1734 description: port network
1745 packet_int_network_name:
1747 description: network name
1750 security_group_name:
1752 description: CMAUI1, CMAUI2 server names
1757 availability_zone_0:
1759 description: availabilityzone name
1762 ps_server_1b_flavor:
1764 description: Flavor for PS server
1769 description: Ps Image server
1774 description: sub interface network
1779 description: Ps server names
1784 packet_ext_network_name:
1786 description: network name
1790 - dependency_server_1b_ps_1:
1791 capability: tosca.capabilities.Node
1792 node: tosca.nodes.Root
1793 relationship: tosca.relationships.DependsOn
1797 - local_storage_server_1b_ps_1:
1798 capability: tosca.capabilities.Attachment
1799 node: tosca.nodes.BlockStorage
1800 relationship: tosca.relationships.AttachesTo
1804 - dependency_test_resourceGroup_1:
1805 capability: tosca.capabilities.Node
1806 node: tosca.nodes.Root
1807 relationship: tosca.relationships.DependsOn
1811 - dependency_template_Vlan_vmi_1_test_resourceGroup_1:
1812 capability: tosca.capabilities.Node
1813 node: tosca.nodes.Root
1814 relationship: tosca.relationships.DependsOn
1818 - dependency_test_resourceGroup_2:
1819 capability: tosca.capabilities.Node
1820 node: tosca.nodes.Root
1821 relationship: tosca.relationships.DependsOn
1825 - dependency_template_Vlan_vmi_1_test_resourceGroup_2:
1826 capability: tosca.capabilities.Node
1827 node: tosca.nodes.Root
1828 relationship: tosca.relationships.DependsOn
1832 - dependency_ps_server_1b_port_1:
1833 capability: tosca.capabilities.Node
1834 node: tosca.nodes.Root
1835 relationship: tosca.relationships.DependsOn
1839 - dependency_ps_server_1b_port_2:
1840 capability: tosca.capabilities.Node
1841 node: tosca.nodes.Root
1842 relationship: tosca.relationships.DependsOn
1846 - dependency_packet_ext_network:
1847 capability: tosca.capabilities.Node
1848 node: tosca.nodes.Root
1849 relationship: tosca.relationships.DependsOn
1853 - dependency_packet_int_network:
1854 capability: tosca.capabilities.Node
1855 node: tosca.nodes.Root
1856 relationship: tosca.relationships.DependsOn
1860 - dependency_server_1b_ps_2:
1861 capability: tosca.capabilities.Node
1862 node: tosca.nodes.Root
1863 relationship: tosca.relationships.DependsOn
1867 - local_storage_server_1b_ps_2:
1868 capability: tosca.capabilities.Attachment
1869 node: tosca.nodes.BlockStorage
1870 relationship: tosca.relationships.AttachesTo
1875 binding_ps_server_1b_port_2:
1876 type: tosca.capabilities.network.Bindable
1878 - org.openecomp.resource.cp.nodes.heat.network.contrailV2.VLANSubInterface
1882 disk.device.latency_server_1b_ps_1:
1883 type: org.openecomp.capabilities.metric.Ceilometer
1884 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1888 disk.device.usage_server_1b_ps_1:
1889 type: org.openecomp.capabilities.metric.Ceilometer
1890 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1894 disk.device.usage_server_1b_ps_2:
1895 type: org.openecomp.capabilities.metric.Ceilometer
1896 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1900 disk.read.requests_server_1b_ps_1:
1901 type: org.openecomp.capabilities.metric.Ceilometer
1902 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1906 disk.device.write.requests.rate_server_1b_ps_1:
1907 type: org.openecomp.capabilities.metric.Ceilometer
1908 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1912 disk.read.requests_server_1b_ps_2:
1913 type: org.openecomp.capabilities.metric.Ceilometer
1914 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1918 disk.device.write.requests.rate_server_1b_ps_2:
1919 type: org.openecomp.capabilities.metric.Ceilometer
1920 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1924 binding_ps_server_1b_port_1:
1925 type: tosca.capabilities.network.Bindable
1927 - org.openecomp.resource.cp.nodes.heat.network.contrailV2.VLANSubInterface
1931 disk.read.bytes_server_1b_ps_1:
1932 type: org.openecomp.capabilities.metric.Ceilometer
1933 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1937 disk.read.bytes_server_1b_ps_2:
1938 type: org.openecomp.capabilities.metric.Ceilometer
1939 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1943 disk.device.latency_server_1b_ps_2:
1944 type: org.openecomp.capabilities.metric.Ceilometer
1945 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1949 disk.root.size_server_1b_ps_1:
1950 type: org.openecomp.capabilities.metric.Ceilometer
1951 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1955 network.incoming.bytes.rate_ps_server_1b_port_2:
1956 type: org.openecomp.capabilities.metric.Ceilometer
1957 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1961 disk.root.size_server_1b_ps_2:
1962 type: org.openecomp.capabilities.metric.Ceilometer
1963 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1967 network.incoming.bytes.rate_ps_server_1b_port_1:
1968 type: org.openecomp.capabilities.metric.Ceilometer
1969 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1973 disk.device.read.requests.rate_server_1b_ps_1:
1974 type: org.openecomp.capabilities.metric.Ceilometer
1975 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1979 disk.device.read.requests.rate_server_1b_ps_2:
1980 type: org.openecomp.capabilities.metric.Ceilometer
1981 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1985 feature_test_resourceGroup_1:
1986 type: tosca.capabilities.Node
1990 network.incoming.bytes_ps_server_1b_port_2:
1991 type: org.openecomp.capabilities.metric.Ceilometer
1992 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1996 network.incoming.bytes_ps_server_1b_port_1:
1997 type: org.openecomp.capabilities.metric.Ceilometer
1998 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2002 attachment_packet_int_network:
2003 type: tosca.capabilities.Attachment
2007 cpu.delta_server_1b_ps_2:
2008 type: org.openecomp.capabilities.metric.Ceilometer
2009 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2013 memory.resident_server_1b_ps_2:
2014 type: org.openecomp.capabilities.metric.Ceilometer
2015 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2019 cpu.delta_server_1b_ps_1:
2020 type: org.openecomp.capabilities.metric.Ceilometer
2021 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2025 memory.resident_server_1b_ps_1:
2026 type: org.openecomp.capabilities.metric.Ceilometer
2027 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2031 cpu_util_server_1b_ps_1:
2032 type: org.openecomp.capabilities.metric.Ceilometer
2033 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2037 disk.device.write.bytes.rate_server_1b_ps_2:
2038 type: org.openecomp.capabilities.metric.Ceilometer
2039 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2043 disk.device.write.bytes.rate_server_1b_ps_1:
2044 type: org.openecomp.capabilities.metric.Ceilometer
2045 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2049 cpu_util_server_1b_ps_2:
2050 type: org.openecomp.capabilities.metric.Ceilometer
2051 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2055 disk.ephemeral.size_server_1b_ps_1:
2056 type: org.openecomp.capabilities.metric.Ceilometer
2057 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2061 disk.ephemeral.size_server_1b_ps_2:
2062 type: org.openecomp.capabilities.metric.Ceilometer
2063 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2067 disk.capacity_server_1b_ps_2:
2068 type: org.openecomp.capabilities.metric.Ceilometer
2069 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2073 memory_server_1b_ps_1:
2074 type: org.openecomp.capabilities.metric.Ceilometer
2075 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2079 network.outgoing.packets.rate_ps_server_1b_port_1:
2080 type: org.openecomp.capabilities.metric.Ceilometer
2081 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2085 disk.capacity_server_1b_ps_1:
2086 type: org.openecomp.capabilities.metric.Ceilometer
2087 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2091 memory_server_1b_ps_2:
2092 type: org.openecomp.capabilities.metric.Ceilometer
2093 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2097 instance_server_1b_ps_1:
2098 type: org.openecomp.capabilities.metric.Ceilometer
2099 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2103 forwarder_ps_server_1b_port_1:
2104 type: org.openecomp.capabilities.Forwarder
2108 forwarder_ps_server_1b_port_2:
2109 type: org.openecomp.capabilities.Forwarder
2113 network.outgoing.packets.rate_ps_server_1b_port_2:
2114 type: org.openecomp.capabilities.metric.Ceilometer
2115 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2119 link_packet_int_network:
2120 type: tosca.capabilities.network.Linkable
2124 instance_server_1b_ps_2:
2125 type: org.openecomp.capabilities.metric.Ceilometer
2126 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2130 feature_template_Vlan_vmi_1_test_resourceGroup_1:
2131 type: tosca.capabilities.Node
2135 feature_template_Vlan_vmi_1_test_resourceGroup_2:
2136 type: tosca.capabilities.Node
2140 disk.device.capacity_server_1b_ps_1:
2141 type: org.openecomp.capabilities.metric.Ceilometer
2142 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2146 end_point_packet_ext_network:
2147 type: tosca.capabilities.Endpoint
2151 disk.device.capacity_server_1b_ps_2:
2152 type: org.openecomp.capabilities.metric.Ceilometer
2153 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2157 network.incoming.packets_ps_server_1b_port_2:
2158 type: org.openecomp.capabilities.metric.Ceilometer
2159 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2163 disk.device.iops_server_1b_ps_2:
2164 type: org.openecomp.capabilities.metric.Ceilometer
2165 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2169 disk.device.iops_server_1b_ps_1:
2170 type: org.openecomp.capabilities.metric.Ceilometer
2171 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2175 network.incoming.packets_ps_server_1b_port_1:
2176 type: org.openecomp.capabilities.metric.Ceilometer
2177 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2181 network.outgoing.bytes.rate_ps_server_1b_port_1:
2182 type: org.openecomp.capabilities.metric.Ceilometer
2183 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2187 network.outpoing.packets_ps_server_1b_port_2:
2188 type: org.openecomp.capabilities.metric.Ceilometer
2189 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2193 network.outpoing.packets_ps_server_1b_port_1:
2194 type: org.openecomp.capabilities.metric.Ceilometer
2195 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2199 endpoint_server_1b_ps_1:
2200 type: tosca.capabilities.Endpoint.Admin
2204 disk.device.allocation_server_1b_ps_1:
2205 type: org.openecomp.capabilities.metric.Ceilometer
2206 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2210 endpoint_server_1b_ps_2:
2211 type: tosca.capabilities.Endpoint.Admin
2215 disk.write.requests.rate_server_1b_ps_2:
2216 type: org.openecomp.capabilities.metric.Ceilometer
2217 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2221 disk.write.requests.rate_server_1b_ps_1:
2222 type: org.openecomp.capabilities.metric.Ceilometer
2223 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2227 host_server_1b_ps_2:
2228 type: tosca.capabilities.Container
2230 - tosca.nodes.SoftwareComponent
2234 host_server_1b_ps_1:
2235 type: tosca.capabilities.Container
2237 - tosca.nodes.SoftwareComponent
2241 feature_packet_int_network:
2242 type: tosca.capabilities.Node
2246 network.outgoing.bytes.rate_ps_server_1b_port_2:
2247 type: org.openecomp.capabilities.metric.Ceilometer
2248 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2252 disk.write.bytes.rate_server_1b_ps_1:
2253 type: org.openecomp.capabilities.metric.Ceilometer
2254 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2258 disk.write.bytes_server_1b_ps_2:
2259 type: org.openecomp.capabilities.metric.Ceilometer
2260 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2264 disk.device.write.bytes_server_1b_ps_2:
2265 type: org.openecomp.capabilities.metric.Ceilometer
2266 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2270 disk.device.write.bytes_server_1b_ps_1:
2271 type: org.openecomp.capabilities.metric.Ceilometer
2272 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2276 disk.write.bytes_server_1b_ps_1:
2277 type: org.openecomp.capabilities.metric.Ceilometer
2278 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2282 disk.write.bytes.rate_server_1b_ps_2:
2283 type: org.openecomp.capabilities.metric.Ceilometer
2284 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2288 disk.device.allocation_server_1b_ps_2:
2289 type: org.openecomp.capabilities.metric.Ceilometer
2290 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2294 scalable_server_1b_ps_1:
2295 type: tosca.capabilities.Scalable
2299 scalable_server_1b_ps_2:
2300 type: tosca.capabilities.Scalable
2304 disk.allocation_server_1b_ps_2:
2305 type: org.openecomp.capabilities.metric.Ceilometer
2306 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2310 disk.allocation_server_1b_ps_1:
2311 type: org.openecomp.capabilities.metric.Ceilometer
2312 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2316 feature_server_1b_ps_2:
2317 type: tosca.capabilities.Node
2321 feature_server_1b_ps_1:
2322 type: tosca.capabilities.Node
2326 vcpus_server_1b_ps_1:
2327 type: org.openecomp.capabilities.metric.Ceilometer
2328 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2332 vcpus_server_1b_ps_2:
2333 type: org.openecomp.capabilities.metric.Ceilometer
2334 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2338 disk.read.bytes.rate_server_1b_ps_2:
2339 type: org.openecomp.capabilities.metric.Ceilometer
2340 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2344 disk.read.bytes.rate_server_1b_ps_1:
2345 type: org.openecomp.capabilities.metric.Ceilometer
2346 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2350 disk.iops_server_1b_ps_1:
2351 type: org.openecomp.capabilities.metric.Ceilometer
2352 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2356 memory.usage_server_1b_ps_2:
2357 type: org.openecomp.capabilities.metric.Ceilometer
2358 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2362 memory.usage_server_1b_ps_1:
2363 type: org.openecomp.capabilities.metric.Ceilometer
2364 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2368 disk.iops_server_1b_ps_2:
2369 type: org.openecomp.capabilities.metric.Ceilometer
2370 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2374 disk.write.requests_server_1b_ps_1:
2375 type: org.openecomp.capabilities.metric.Ceilometer
2376 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2380 disk.write.requests_server_1b_ps_2:
2381 type: org.openecomp.capabilities.metric.Ceilometer
2382 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2386 network.incoming.packets.rate_ps_server_1b_port_2:
2387 type: org.openecomp.capabilities.metric.Ceilometer
2388 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2392 disk.latency_server_1b_ps_2:
2393 type: org.openecomp.capabilities.metric.Ceilometer
2394 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2398 disk.latency_server_1b_ps_1:
2399 type: org.openecomp.capabilities.metric.Ceilometer
2400 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2404 network.incoming.packets.rate_ps_server_1b_port_1:
2405 type: org.openecomp.capabilities.metric.Ceilometer
2406 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2410 binding_server_1b_ps_1:
2411 type: tosca.capabilities.network.Bindable
2415 link_packet_ext_network:
2416 type: tosca.capabilities.network.Linkable
2420 binding_server_1b_ps_2:
2421 type: tosca.capabilities.network.Bindable
2425 disk.device.write.requests_server_1b_ps_1:
2426 type: org.openecomp.capabilities.metric.Ceilometer
2427 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2431 disk.device.read.requests_server_1b_ps_2:
2432 type: org.openecomp.capabilities.metric.Ceilometer
2433 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2437 disk.device.write.requests_server_1b_ps_2:
2438 type: org.openecomp.capabilities.metric.Ceilometer
2439 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2443 disk.device.read.requests_server_1b_ps_1:
2444 type: org.openecomp.capabilities.metric.Ceilometer
2445 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2449 end_point_packet_int_network:
2450 type: tosca.capabilities.Endpoint
2454 attachment_ps_server_1b_port_1:
2455 type: tosca.capabilities.Attachment
2459 attachment_ps_server_1b_port_2:
2460 type: tosca.capabilities.Attachment
2464 attachment_packet_ext_network:
2465 type: tosca.capabilities.Attachment
2470 type: tosca.capabilities.OperatingSystem
2475 type: tosca.capabilities.OperatingSystem
2479 feature_test_resourceGroup_2:
2480 type: tosca.capabilities.Node
2484 network.outgoing.bytes_ps_server_1b_port_2:
2485 type: org.openecomp.capabilities.metric.Ceilometer
2486 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2490 network.outgoing.bytes_ps_server_1b_port_1:
2491 type: org.openecomp.capabilities.metric.Ceilometer
2492 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2496 disk.usage_server_1b_ps_2:
2497 type: org.openecomp.capabilities.metric.Ceilometer
2498 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2502 disk.usage_server_1b_ps_1:
2503 type: org.openecomp.capabilities.metric.Ceilometer
2504 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2508 disk.device.read.bytes_server_1b_ps_2:
2509 type: org.openecomp.capabilities.metric.Ceilometer
2510 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2514 disk.device.read.bytes_server_1b_ps_1:
2515 type: org.openecomp.capabilities.metric.Ceilometer
2516 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2521 type: org.openecomp.capabilities.metric.Ceilometer
2522 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2527 type: org.openecomp.capabilities.metric.Ceilometer
2528 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2532 feature_packet_ext_network:
2533 type: tosca.capabilities.Node
2537 feature_ps_server_1b_port_1:
2538 type: tosca.capabilities.Node
2542 feature_ps_server_1b_port_2:
2543 type: tosca.capabilities.Node
2547 disk.device.read.bytes.rate_server_1b_ps_1:
2548 type: org.openecomp.capabilities.metric.Ceilometer
2549 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2553 disk.device.read.bytes.rate_server_1b_ps_2:
2554 type: org.openecomp.capabilities.metric.Ceilometer
2555 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2559 org.openecomp.resource.abstract.nodes.ps_server_1b:
2560 derived_from: org.openecomp.resource.abstract.nodes.VFC
2562 port_ps_server_1b_port_vlan_requirements:
2567 type: org.openecomp.datatypes.network.VlanRequirements
2568 port_ps_server_1b_port_mac_requirements:
2569 type: org.openecomp.datatypes.network.MacRequirements
2572 port_ps_server_1b_port_network_role_tag:
2576 port_ps_server_1b_port_fixed_ips:
2581 type: org.openecomp.datatypes.heat.neutron.port.FixedIps
2584 description: Index value of this substitution service template runtime instance
2589 - greater_or_equal: 0
2590 port_ps_server_1b_port_order:
2598 port_ps_server_1b_port_network:
2604 port_ps_server_1b_port_exCP_naming:
2605 type: org.openecomp.datatypes.Naming
2608 subinterface_nested_vlan_net1:
2614 port_ps_server_1b_port_ip_requirements:
2619 type: org.openecomp.datatypes.network.IpRequirements
2624 port_ps_server_1b_port_network_role:
2628 port_ps_server_1b_port_replacement_policy:
2634 subinterface_nested_vlan_parent_interface:
2640 port_ps_server_1b_port_subnetpoolid:
2644 compute_ps_server_1b_availability_zone:
2650 compute_ps_server_1b_name:
2657 - dependency_ps_server_1b:
2658 capability: tosca.capabilities.Node
2659 node: tosca.nodes.Root
2660 relationship: tosca.relationships.DependsOn
2664 - local_storage_ps_server_1b:
2665 capability: tosca.capabilities.Attachment
2666 node: tosca.nodes.BlockStorage
2667 relationship: tosca.relationships.AttachesTo
2671 - dependency_ps_server_1b_ps_server_1b_port_nested_vlan:
2672 capability: tosca.capabilities.Node
2673 node: tosca.nodes.Root
2674 relationship: tosca.relationships.DependsOn
2678 - dependency_template_Vlan_vmi_1_ps_server_1b_ps_server_1b_port_nested_vlan:
2679 capability: tosca.capabilities.Node
2680 node: tosca.nodes.Root
2681 relationship: tosca.relationships.DependsOn
2685 - link_template_Vlan_vmi_1_ps_server_1b_ps_server_1b_port_nested_vlan:
2686 capability: tosca.capabilities.network.Linkable
2687 relationship: tosca.relationships.network.LinksTo
2691 - dependency_ps_server_1b_ps_server_1b_port:
2692 capability: tosca.capabilities.Node
2693 node: tosca.nodes.Root
2694 relationship: tosca.relationships.DependsOn
2698 - link_ps_server_1b_ps_server_1b_port:
2699 capability: tosca.capabilities.network.Linkable
2700 relationship: tosca.relationships.network.LinksTo
2705 disk.write.bytes.rate_ps_server_1b:
2706 type: org.openecomp.capabilities.metric.Ceilometer
2707 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2711 disk.device.usage_ps_server_1b:
2712 type: org.openecomp.capabilities.metric.Ceilometer
2713 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2717 disk.device.allocation_ps_server_1b:
2718 type: org.openecomp.capabilities.metric.Ceilometer
2719 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2723 disk.device.write.requests_ps_server_1b:
2724 type: org.openecomp.capabilities.metric.Ceilometer
2725 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2729 cpu_util_ps_server_1b:
2730 type: org.openecomp.capabilities.metric.Ceilometer
2731 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2735 scalable_ps_server_1b:
2736 type: tosca.capabilities.Scalable
2740 disk.device.read.bytes.rate_ps_server_1b:
2741 type: org.openecomp.capabilities.metric.Ceilometer
2742 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2746 disk.device.latency_ps_server_1b:
2747 type: org.openecomp.capabilities.metric.Ceilometer
2748 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2752 disk.device.iops_ps_server_1b:
2753 type: org.openecomp.capabilities.metric.Ceilometer
2754 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2758 attachment_ps_server_1b_ps_server_1b_port:
2759 type: tosca.capabilities.Attachment
2763 network.outgoing.packets.rate_ps_server_1b_ps_server_1b_port:
2764 type: org.openecomp.capabilities.metric.Ceilometer
2765 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2769 disk.device.capacity_ps_server_1b:
2770 type: org.openecomp.capabilities.metric.Ceilometer
2771 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2775 forwarder_ps_server_1b_ps_server_1b_port:
2776 type: org.openecomp.capabilities.Forwarder
2780 instance_ps_server_1b:
2781 type: org.openecomp.capabilities.metric.Ceilometer
2782 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2787 type: org.openecomp.capabilities.metric.Ceilometer
2788 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2792 disk.device.write.bytes_ps_server_1b:
2793 type: org.openecomp.capabilities.metric.Ceilometer
2794 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2798 disk.read.bytes.rate_ps_server_1b:
2799 type: org.openecomp.capabilities.metric.Ceilometer
2800 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2804 disk.device.read.requests_ps_server_1b:
2805 type: org.openecomp.capabilities.metric.Ceilometer
2806 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2811 type: tosca.capabilities.Container
2813 - tosca.nodes.SoftwareComponent
2817 disk.usage_ps_server_1b:
2818 type: org.openecomp.capabilities.metric.Ceilometer
2819 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2823 disk.read.requests_ps_server_1b:
2824 type: org.openecomp.capabilities.metric.Ceilometer
2825 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2829 feature_ps_server_1b_ps_server_1b_port_nested_vlan:
2830 type: tosca.capabilities.Node
2834 disk.device.read.requests.rate_ps_server_1b:
2835 type: org.openecomp.capabilities.metric.Ceilometer
2836 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2840 disk.capacity_ps_server_1b:
2841 type: org.openecomp.capabilities.metric.Ceilometer
2842 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2846 network.incoming.bytes_ps_server_1b_ps_server_1b_port:
2847 type: org.openecomp.capabilities.metric.Ceilometer
2848 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2852 disk.write.requests.rate_ps_server_1b:
2853 type: org.openecomp.capabilities.metric.Ceilometer
2854 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2858 disk.device.read.bytes_ps_server_1b:
2859 type: org.openecomp.capabilities.metric.Ceilometer
2860 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2864 disk.device.write.requests.rate_ps_server_1b:
2865 type: org.openecomp.capabilities.metric.Ceilometer
2866 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2870 disk.root.size_ps_server_1b:
2871 type: org.openecomp.capabilities.metric.Ceilometer
2872 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2876 binding_ps_server_1b:
2877 type: tosca.capabilities.network.Bindable
2881 memory.resident_ps_server_1b:
2882 type: org.openecomp.capabilities.metric.Ceilometer
2883 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2887 memory_ps_server_1b:
2888 type: org.openecomp.capabilities.metric.Ceilometer
2889 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2893 disk.write.bytes_ps_server_1b:
2894 type: org.openecomp.capabilities.metric.Ceilometer
2895 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2899 disk.device.write.bytes.rate_ps_server_1b:
2900 type: org.openecomp.capabilities.metric.Ceilometer
2901 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2905 disk.read.bytes_ps_server_1b:
2906 type: org.openecomp.capabilities.metric.Ceilometer
2907 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2911 network.incoming.packets.rate_ps_server_1b_ps_server_1b_port:
2912 type: org.openecomp.capabilities.metric.Ceilometer
2913 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2917 network.outgoing.bytes_ps_server_1b_ps_server_1b_port:
2918 type: org.openecomp.capabilities.metric.Ceilometer
2919 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2923 network.incoming.packets_ps_server_1b_ps_server_1b_port:
2924 type: org.openecomp.capabilities.metric.Ceilometer
2925 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2929 network.outgoing.bytes.rate_ps_server_1b_ps_server_1b_port:
2930 type: org.openecomp.capabilities.metric.Ceilometer
2931 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2935 feature_ps_server_1b:
2936 type: tosca.capabilities.Node
2941 type: tosca.capabilities.OperatingSystem
2945 disk.iops_ps_server_1b:
2946 type: org.openecomp.capabilities.metric.Ceilometer
2947 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2951 disk.allocation_ps_server_1b:
2952 type: org.openecomp.capabilities.metric.Ceilometer
2953 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2957 disk.write.requests_ps_server_1b:
2958 type: org.openecomp.capabilities.metric.Ceilometer
2959 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2963 network.outpoing.packets_ps_server_1b_ps_server_1b_port:
2964 type: org.openecomp.capabilities.metric.Ceilometer
2965 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2969 memory.usage_ps_server_1b:
2970 type: org.openecomp.capabilities.metric.Ceilometer
2971 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2975 disk.latency_ps_server_1b:
2976 type: org.openecomp.capabilities.metric.Ceilometer
2977 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2981 endpoint_ps_server_1b:
2982 type: tosca.capabilities.Endpoint.Admin
2986 network.incoming.bytes.rate_ps_server_1b_ps_server_1b_port:
2987 type: org.openecomp.capabilities.metric.Ceilometer
2988 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
2992 feature_ps_server_1b_ps_server_1b_port:
2993 type: tosca.capabilities.Node
2998 type: org.openecomp.capabilities.metric.Ceilometer
2999 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
3003 cpu.delta_ps_server_1b:
3004 type: org.openecomp.capabilities.metric.Ceilometer
3005 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
3009 disk.ephemeral.size_ps_server_1b:
3010 type: org.openecomp.capabilities.metric.Ceilometer
3011 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
3015 binding_ps_server_1b_ps_server_1b_port:
3016 type: tosca.capabilities.network.Bindable
3018 - org.openecomp.resource.cp.nodes.heat.network.contrailV2.VLANSubInterface
3022 feature_template_Vlan_vmi_1_ps_server_1b_ps_server_1b_port_nested_vlan:
3023 type: tosca.capabilities.Node
3027 org.openecomp.resource.abstract.nodes.heat.subinterface.nested_vlan:
3028 derived_from: org.openecomp.resource.abstract.nodes.AbstractSubstitute
3038 virtual_ipv6_address:
3046 lb_st_vlan_type_oam:
3059 subinterface_name_prefix:
3063 subinterface_instance_index:
3068 - dependency_template_Vlan_vmi_1:
3069 capability: tosca.capabilities.Node
3070 node: tosca.nodes.Root
3071 relationship: tosca.relationships.DependsOn
3075 - link_template_Vlan_vmi_1:
3076 capability: tosca.capabilities.network.Linkable
3077 relationship: tosca.relationships.network.LinksTo
3081 - binding_template_Vlan_vmi_1:
3082 capability: tosca.capabilities.network.Bindable
3083 node: org.openecomp.resource.cp.nodes.network.Port
3084 relationship: tosca.relationships.network.BindsTo
3089 feature_template_Vlan_vmi_1:
3090 type: tosca.capabilities.Node