1 tosca_definitions_version: tosca_simple_yaml_1_0_0
 
   3   template_name: Nested_pcma_server
 
   5 - openecomp_heat_index:
 
   6     file: openecomp-heat/_index.yml
 
   7 - GlobalSubstitutionTypes:
 
   8     file: GlobalSubstitutionTypesServiceTemplate.yaml
 
  10   org.openecomp.resource.vfc.compute.nodes.heat.pcma_server:
 
  11     derived_from: org.openecomp.resource.vfc.nodes.heat.nova.Server
 
  14     port_pcm_port_3_mac_requirements:
 
  15       type: org.openecomp.datatypes.network.MacRequirements
 
  17     port_pcm_port_2_network_role:
 
  20     port_pcm_port_2_fixed_ips:
 
  24         type: org.openecomp.datatypes.heat.neutron.port.FixedIps
 
  25     port_pcm_port_3_network_role:
 
  28     port_pcm_port_3_vlan_requirements:
 
  32         type: org.openecomp.datatypes.network.VlanRequirements
 
  36     port_pcm_port_3_security_groups:
 
  41     port_pcm_port_3_order:
 
  44     compute_pcma_server_availability_zone:
 
  52     port_pcm_port_2_security_groups:
 
  57     port_pcm_port_2_exCP_naming:
 
  58       type: org.openecomp.datatypes.Naming
 
  60     port_pcm_port_3_ip_requirements:
 
  64         type: org.openecomp.datatypes.network.IpRequirements
 
  65     port_pcm_port_2_subnetpoolid:
 
  68     port_pcm_port_2_mac_requirements:
 
  69       type: org.openecomp.datatypes.network.MacRequirements
 
  71     port_pcm_port_2_vlan_requirements:
 
  75         type: org.openecomp.datatypes.network.VlanRequirements
 
  76     port_pcm_port_3_subnetpoolid:
 
  79     port_pcm_port_3_network_role_tag:
 
  82     compute_pcma_server_config_drive:
 
  87     port_pcm_port_3_fixed_ips:
 
  91         type: org.openecomp.datatypes.heat.neutron.port.FixedIps
 
  94       description: Index value of this substitution service template runtime instance
 
  99     compute_pcma_server_user_data_format:
 
 104     port_pcm_port_2_order:
 
 107     port_pcm_port_3_exCP_naming:
 
 108       type: org.openecomp.datatypes.Naming
 
 110     port_pcm_port_2_network:
 
 115     port_pcm_port_2_ip_requirements:
 
 119         type: org.openecomp.datatypes.network.IpRequirements
 
 120     port_pcm_port_2_network_role_tag:
 
 123     port_pcm_port_3_network:
 
 128     compute_pcma_server_scheduler_hints:
 
 133     compute_pcma_server_name:
 
 140       type: org.openecomp.resource.vfc.compute.nodes.heat.pcma_server
 
 144           - compute_pcma_server_availability_zone
 
 147           get_input: vm_flavor_name
 
 150           - compute_pcma_server_config_drive
 
 153           get_input: vm_image_name
 
 156           - compute_pcma_server_name
 
 160           - compute_pcma_server_scheduler_hints
 
 164           - compute_pcma_server_user_data_format
 
 166     pcma_server_pcm_port_3:
 
 167       type: org.openecomp.resource.cp.nodes.heat.network.neutron.Port
 
 171           - port_pcm_port_3_security_groups
 
 174           get_input: port_pcm_port_3_exCP_naming
 
 176           get_input: port_pcm_port_3_vlan_requirements
 
 178           get_input: port_pcm_port_3_ip_requirements
 
 180           get_input: port_pcm_port_3_network_role_tag
 
 182           get_input: port_pcm_port_3_mac_requirements
 
 184           get_input: port_pcm_port_3_order
 
 186           get_input: port_pcm_port_3_network_role
 
 188           get_input: port_pcm_port_3_subnetpoolid
 
 190           get_input: port_pcm_port_3_fixed_ips
 
 193           - port_pcm_port_3_network
 
 197           capability: tosca.capabilities.network.Bindable
 
 199           relationship: tosca.relationships.network.BindsTo
 
 200     pcma_server_pcm_port_2:
 
 201       type: org.openecomp.resource.cp.nodes.heat.network.neutron.Port
 
 205           - port_pcm_port_2_security_groups
 
 208           get_input: port_pcm_port_2_exCP_naming
 
 210           get_input: port_pcm_port_2_vlan_requirements
 
 212           get_input: port_pcm_port_2_ip_requirements
 
 214           get_input: port_pcm_port_2_network_role_tag
 
 216           get_input: port_pcm_port_2_mac_requirements
 
 218           get_input: port_pcm_port_2_order
 
 220           get_input: port_pcm_port_2_network_role
 
 222           get_input: port_pcm_port_2_subnetpoolid
 
 224           get_input: port_pcm_port_2_fixed_ips
 
 227           - port_pcm_port_2_network
 
 231           capability: tosca.capabilities.network.Bindable
 
 233           relationship: tosca.relationships.network.BindsTo
 
 234   substitution_mappings:
 
 235     node_type: org.openecomp.resource.abstract.nodes.pcma_server
 
 237       cpu.delta_pcma_server:
 
 240       scalable_pcma_server:
 
 249       disk.device.read.requests.rate_pcma_server:
 
 251       - disk.device.read.requests.rate
 
 252       disk.usage_pcma_server:
 
 255       network.outgoing.bytes.rate_pcma_server_pcm_port_3:
 
 256       - pcma_server_pcm_port_3
 
 257       - network.outgoing.bytes.rate
 
 258       disk.read.bytes_pcma_server:
 
 261       disk.iops_pcma_server:
 
 264       network.outgoing.bytes.rate_pcma_server_pcm_port_2:
 
 265       - pcma_server_pcm_port_2
 
 266       - network.outgoing.bytes.rate
 
 267       attachment_pcma_server_pcm_port_2:
 
 268       - pcma_server_pcm_port_2
 
 270       endpoint_pcma_server:
 
 276       attachment_pcma_server_pcm_port_3:
 
 277       - pcma_server_pcm_port_3
 
 279       network.incoming.bytes.rate_pcma_server_pcm_port_2:
 
 280       - pcma_server_pcm_port_2
 
 281       - network.incoming.bytes.rate
 
 282       memory.usage_pcma_server:
 
 285       network.outgoing.bytes_pcma_server_pcm_port_3:
 
 286       - pcma_server_pcm_port_3
 
 287       - network.outgoing.bytes
 
 288       binding_pcma_server_pcm_port_3:
 
 289       - pcma_server_pcm_port_3
 
 291       network.incoming.bytes.rate_pcma_server_pcm_port_3:
 
 292       - pcma_server_pcm_port_3
 
 293       - network.incoming.bytes.rate
 
 297       network.outgoing.bytes_pcma_server_pcm_port_2:
 
 298       - pcma_server_pcm_port_2
 
 299       - network.outgoing.bytes
 
 303       disk.device.write.bytes.rate_pcma_server:
 
 305       - disk.device.write.bytes.rate
 
 306       disk.read.bytes.rate_pcma_server:
 
 308       - disk.read.bytes.rate
 
 309       network.incoming.packets_pcma_server_pcm_port_3:
 
 310       - pcma_server_pcm_port_3
 
 311       - network.incoming.packets
 
 312       binding_pcma_server_pcm_port_2:
 
 313       - pcma_server_pcm_port_2
 
 318       network.incoming.packets_pcma_server_pcm_port_2:
 
 319       - pcma_server_pcm_port_2
 
 320       - network.incoming.packets
 
 321       network.incoming.packets.rate_pcma_server_pcm_port_3:
 
 322       - pcma_server_pcm_port_3
 
 323       - network.incoming.packets.rate
 
 324       network.outgoing.packets.rate_pcma_server_pcm_port_3:
 
 325       - pcma_server_pcm_port_3
 
 326       - network.outgoing.packets.rate
 
 327       network.incoming.packets.rate_pcma_server_pcm_port_2:
 
 328       - pcma_server_pcm_port_2
 
 329       - network.incoming.packets.rate
 
 330       disk.device.read.requests_pcma_server:
 
 332       - disk.device.read.requests
 
 333       disk.write.bytes.rate_pcma_server:
 
 335       - disk.write.bytes.rate
 
 336       network.outgoing.packets.rate_pcma_server_pcm_port_2:
 
 337       - pcma_server_pcm_port_2
 
 338       - network.outgoing.packets.rate
 
 339       disk.device.write.requests.rate_pcma_server:
 
 341       - disk.device.write.requests.rate
 
 342       cpu_util_pcma_server:
 
 345       disk.device.write.bytes_pcma_server:
 
 347       - disk.device.write.bytes
 
 348       disk.device.read.bytes.rate_pcma_server:
 
 350       - disk.device.read.bytes.rate
 
 351       disk.device.usage_pcma_server:
 
 354       disk.read.requests_pcma_server:
 
 357       disk.allocation_pcma_server:
 
 360       feature_pcma_server_pcm_port_2:
 
 361       - pcma_server_pcm_port_2
 
 363       feature_pcma_server_pcm_port_3:
 
 364       - pcma_server_pcm_port_3
 
 366       disk.ephemeral.size_pcma_server:
 
 368       - disk.ephemeral.size
 
 372       disk.latency_pcma_server:
 
 375       disk.device.write.requests_pcma_server:
 
 377       - disk.device.write.requests
 
 378       disk.device.read.bytes_pcma_server:
 
 380       - disk.device.read.bytes
 
 381       disk.device.allocation_pcma_server:
 
 383       - disk.device.allocation
 
 384       memory.resident_pcma_server:
 
 387       disk.root.size_pcma_server:
 
 390       disk.write.bytes_pcma_server:
 
 393       disk.write.requests_pcma_server:
 
 395       - disk.write.requests
 
 396       network.incoming.bytes_pcma_server_pcm_port_2:
 
 397       - pcma_server_pcm_port_2
 
 398       - network.incoming.bytes
 
 399       network.incoming.bytes_pcma_server_pcm_port_3:
 
 400       - pcma_server_pcm_port_3
 
 401       - network.incoming.bytes
 
 402       disk.write.requests.rate_pcma_server:
 
 404       - disk.write.requests.rate
 
 405       disk.device.iops_pcma_server:
 
 408       instance_pcma_server:
 
 411       network.outpoing.packets_pcma_server_pcm_port_3:
 
 412       - pcma_server_pcm_port_3
 
 413       - network.outpoing.packets
 
 414       disk.device.latency_pcma_server:
 
 416       - disk.device.latency
 
 417       network.outpoing.packets_pcma_server_pcm_port_2:
 
 418       - pcma_server_pcm_port_2
 
 419       - network.outpoing.packets
 
 420       disk.capacity_pcma_server:
 
 423       disk.device.capacity_pcma_server:
 
 425       - disk.device.capacity
 
 427       dependency_pcma_server_pcm_port_3:
 
 428       - pcma_server_pcm_port_3
 
 430       dependency_pcma_server:
 
 433       dependency_pcma_server_pcm_port_2:
 
 434       - pcma_server_pcm_port_2
 
 436       local_storage_pcma_server:
 
 439       link_pcma_server_pcm_port_2:
 
 440       - pcma_server_pcm_port_2
 
 442       link_pcma_server_pcm_port_3:
 
 443       - pcma_server_pcm_port_3