1 tosca_definitions_version: tosca_simple_yaml_1_0_0
3 template_name: GlobalSubstitutionTypes
5 - openecomp_heat_index:
6 file: openecomp-heat/_index.yml
8 org.openecomp.resource.abstract.nodes.pd_server:
9 derived_from: org.openecomp.resource.abstract.nodes.VFC
11 port_pd_server_0_oam_port_0_exCP_naming:
12 type: org.openecomp.datatypes.Naming
15 compute_pd_server_availability_zone:
21 compute_pd_server_name:
31 port_pd_server_1_oam_port_0_mac_requirements:
32 type: org.openecomp.datatypes.network.MacRequirements
39 port_pd_server_0_oam_port_0_network_role_tag:
43 port_pd_server_0_oam_port_0_related_networks:
48 type: org.openecomp.datatypes.network.RelatedNetworksAssignments
49 port_pd_server_1_oam_port_0_order:
53 port_pd_server_0_oam_port_0_subnetpoolid:
57 port_pd_server_1_oam_port_0_subnetpoolid:
61 compute_pd_server_user_data_format:
67 port_pd_server_0_oam_port_0_vlan_requirements:
72 type: org.openecomp.datatypes.network.VlanRequirements
73 port_pd_server_0_oam_port_0_network_role:
77 port_pd_server_1_oam_port_0_exCP_naming:
78 type: org.openecomp.datatypes.Naming
81 port_pd_server_0_oam_port_0_order:
87 description: Index value of this substitution service template runtime instance
93 port_pd_server_1_oam_port_0_network_role_tag:
97 port_pd_server_1_oam_port_0_related_networks:
102 type: org.openecomp.datatypes.network.RelatedNetworksAssignments
103 port_pd_server_1_oam_port_0_vlan_requirements:
108 type: org.openecomp.datatypes.network.VlanRequirements
109 port_pd_server_0_oam_port_0_ip_requirements:
114 type: org.openecomp.datatypes.network.IpRequirements
115 port_pd_server_1_oam_port_0_network_role:
119 port_pd_server_1_oam_port_0_network:
125 port_pd_server_0_oam_port_0_network:
131 port_pd_server_1_oam_port_0_ip_requirements:
136 type: org.openecomp.datatypes.network.IpRequirements
137 port_pd_server_0_oam_port_0_mac_requirements:
138 type: org.openecomp.datatypes.network.MacRequirements
142 - dependency_pd_server:
143 capability: tosca.capabilities.Node
144 node: tosca.nodes.Root
145 relationship: tosca.relationships.DependsOn
149 - local_storage_pd_server:
150 capability: tosca.capabilities.Attachment
151 node: tosca.nodes.BlockStorage
152 relationship: tosca.relationships.AttachesTo
156 - dependency_pd_server_pd_server_1_oam_port_0:
157 capability: tosca.capabilities.Node
158 node: tosca.nodes.Root
159 relationship: tosca.relationships.DependsOn
163 - link_pd_server_pd_server_1_oam_port_0:
164 capability: tosca.capabilities.network.Linkable
165 relationship: tosca.relationships.network.LinksTo
169 - dependency_pd_server_pd_server_0_oam_port_0:
170 capability: tosca.capabilities.Node
171 node: tosca.nodes.Root
172 relationship: tosca.relationships.DependsOn
176 - link_pd_server_pd_server_0_oam_port_0:
177 capability: tosca.capabilities.network.Linkable
178 relationship: tosca.relationships.network.LinksTo
184 type: tosca.capabilities.Scalable
188 disk.read.bytes.rate_pd_server:
189 type: org.openecomp.capabilities.metric.Ceilometer
190 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
194 network.outgoing.bytes_pd_server_pd_server_1_oam_port_0:
195 type: org.openecomp.capabilities.metric.Ceilometer
196 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
200 memory.usage_pd_server:
201 type: org.openecomp.capabilities.metric.Ceilometer
202 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
207 type: org.openecomp.capabilities.metric.Ceilometer
208 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
212 disk.device.usage_pd_server:
213 type: org.openecomp.capabilities.metric.Ceilometer
214 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
218 forwarder_pd_server_pd_server_0_oam_port_0:
219 type: org.openecomp.capabilities.Forwarder
224 type: tosca.capabilities.OperatingSystem
228 disk.write.bytes.rate_pd_server:
229 type: org.openecomp.capabilities.metric.Ceilometer
230 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
234 feature_pd_server_pd_server_0_oam_port_0:
235 type: tosca.capabilities.Node
239 network.incoming.bytes_pd_server_pd_server_1_oam_port_0:
240 type: org.openecomp.capabilities.metric.Ceilometer
241 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
246 type: org.openecomp.capabilities.metric.Ceilometer
247 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
252 type: org.openecomp.capabilities.metric.Ceilometer
253 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
257 disk.device.write.requests.rate_pd_server:
258 type: org.openecomp.capabilities.metric.Ceilometer
259 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
263 disk.read.bytes_pd_server:
264 type: org.openecomp.capabilities.metric.Ceilometer
265 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
269 binding_pd_server_pd_server_1_oam_port_0:
270 type: tosca.capabilities.network.Bindable
272 - org.openecomp.resource.cp.nodes.heat.network.contrailV2.VLANSubInterface
273 - org.openecomp.resource.cp.nodes.heat.network.v2.contrailV2.VLANSubInterface
277 disk.device.read.bytes.rate_pd_server:
278 type: org.openecomp.capabilities.metric.Ceilometer
279 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
283 network.outgoing.packets.rate_pd_server_pd_server_0_oam_port_0:
284 type: org.openecomp.capabilities.metric.Ceilometer
285 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
290 type: org.openecomp.capabilities.metric.Ceilometer
291 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
295 memory.resident_pd_server:
296 type: org.openecomp.capabilities.metric.Ceilometer
297 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
302 type: org.openecomp.capabilities.metric.Ceilometer
303 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
308 type: org.openecomp.capabilities.metric.Ceilometer
309 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
313 disk.device.write.bytes.rate_pd_server:
314 type: org.openecomp.capabilities.metric.Ceilometer
315 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
319 disk.device.write.requests_pd_server:
320 type: org.openecomp.capabilities.metric.Ceilometer
321 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
326 type: tosca.capabilities.Endpoint.Admin
330 forwarder_pd_server_pd_server_1_oam_port_0:
331 type: org.openecomp.capabilities.Forwarder
335 disk.capacity_pd_server:
336 type: org.openecomp.capabilities.metric.Ceilometer
337 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
341 network.incoming.bytes_pd_server_pd_server_0_oam_port_0:
342 type: org.openecomp.capabilities.metric.Ceilometer
343 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
347 network.outgoing.bytes.rate_pd_server_pd_server_0_oam_port_0:
348 type: org.openecomp.capabilities.metric.Ceilometer
349 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
353 disk.device.allocation_pd_server:
354 type: org.openecomp.capabilities.metric.Ceilometer
355 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
359 disk.allocation_pd_server:
360 type: org.openecomp.capabilities.metric.Ceilometer
361 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
366 type: tosca.capabilities.network.Bindable
370 disk.read.requests_pd_server:
371 type: org.openecomp.capabilities.metric.Ceilometer
372 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
376 binding_pd_server_pd_server_0_oam_port_0:
377 type: tosca.capabilities.network.Bindable
379 - org.openecomp.resource.cp.nodes.heat.network.contrailV2.VLANSubInterface
380 - org.openecomp.resource.cp.nodes.heat.network.v2.contrailV2.VLANSubInterface
385 type: tosca.capabilities.Node
389 disk.usage_pd_server:
390 type: org.openecomp.capabilities.metric.Ceilometer
391 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
395 network.outgoing.bytes.rate_pd_server_pd_server_1_oam_port_0:
396 type: org.openecomp.capabilities.metric.Ceilometer
397 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
401 disk.write.bytes_pd_server:
402 type: org.openecomp.capabilities.metric.Ceilometer
403 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
407 network.incoming.packets_pd_server_pd_server_0_oam_port_0:
408 type: org.openecomp.capabilities.metric.Ceilometer
409 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
413 network.outgoing.bytes_pd_server_pd_server_0_oam_port_0:
414 type: org.openecomp.capabilities.metric.Ceilometer
415 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
419 attachment_pd_server_pd_server_0_oam_port_0:
420 type: tosca.capabilities.Attachment
424 disk.device.read.requests.rate_pd_server:
425 type: org.openecomp.capabilities.metric.Ceilometer
426 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
430 disk.root.size_pd_server:
431 type: org.openecomp.capabilities.metric.Ceilometer
432 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
436 disk.device.read.bytes_pd_server:
437 type: org.openecomp.capabilities.metric.Ceilometer
438 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
442 feature_pd_server_pd_server_1_oam_port_0:
443 type: tosca.capabilities.Node
447 network.incoming.bytes.rate_pd_server_pd_server_1_oam_port_0:
448 type: org.openecomp.capabilities.metric.Ceilometer
449 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
453 disk.device.write.bytes_pd_server:
454 type: org.openecomp.capabilities.metric.Ceilometer
455 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
459 network.incoming.packets_pd_server_pd_server_1_oam_port_0:
460 type: org.openecomp.capabilities.metric.Ceilometer
461 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
465 disk.device.read.requests_pd_server:
466 type: org.openecomp.capabilities.metric.Ceilometer
467 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
472 type: org.openecomp.capabilities.metric.Ceilometer
473 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
478 type: tosca.capabilities.Container
480 - tosca.nodes.SoftwareComponent
484 attachment_pd_server_pd_server_1_oam_port_0:
485 type: tosca.capabilities.Attachment
489 network.incoming.packets.rate_pd_server_pd_server_1_oam_port_0:
490 type: org.openecomp.capabilities.metric.Ceilometer
491 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
495 network.outpoing.packets_pd_server_pd_server_1_oam_port_0:
496 type: org.openecomp.capabilities.metric.Ceilometer
497 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
501 disk.write.requests.rate_pd_server:
502 type: org.openecomp.capabilities.metric.Ceilometer
503 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
507 disk.ephemeral.size_pd_server:
508 type: org.openecomp.capabilities.metric.Ceilometer
509 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
513 network.outgoing.packets.rate_pd_server_pd_server_1_oam_port_0:
514 type: org.openecomp.capabilities.metric.Ceilometer
515 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
519 network.incoming.bytes.rate_pd_server_pd_server_0_oam_port_0:
520 type: org.openecomp.capabilities.metric.Ceilometer
521 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
525 disk.write.requests_pd_server:
526 type: org.openecomp.capabilities.metric.Ceilometer
527 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
531 network.incoming.packets.rate_pd_server_pd_server_0_oam_port_0:
532 type: org.openecomp.capabilities.metric.Ceilometer
533 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
537 disk.device.latency_pd_server:
538 type: org.openecomp.capabilities.metric.Ceilometer
539 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
543 disk.latency_pd_server:
544 type: org.openecomp.capabilities.metric.Ceilometer
545 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
549 disk.device.capacity_pd_server:
550 type: org.openecomp.capabilities.metric.Ceilometer
551 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
555 disk.device.iops_pd_server:
556 type: org.openecomp.capabilities.metric.Ceilometer
557 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
561 network.outpoing.packets_pd_server_pd_server_0_oam_port_0:
562 type: org.openecomp.capabilities.metric.Ceilometer
563 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.