1 tosca_definitions_version: tosca_simple_yaml_1_0_0
3 template_name: GlobalSubstitutionTypes
5 - openecomp_heat_index:
6 file: openecomp-heat/_index.yml
8 org.openecomp.resource.abstract.nodes.pd_server:
9 derived_from: org.openecomp.resource.abstract.nodes.VFC
11 port_pd01_port1_network:
17 port_pd01_port1_exCP_naming:
18 type: org.openecomp.datatypes.Naming
21 port_pd01_port1_network_role_tag:
25 port_pd01_port2_network:
31 port_pd01_port1_mac_requirements:
32 type: org.openecomp.datatypes.network.MacRequirements
35 port_pd01_port2_ip_requirements:
40 type: org.openecomp.datatypes.network.IpRequirements
43 description: Index value of this substitution service template runtime instance
49 compute_pd_server_availability_zone:
55 compute_pd_server_name:
61 port_pd01_port1_subnetpoolid:
65 port_pd01_port2_subnetpoolid:
69 port_pd01_port2_network_role:
77 port_pd01_port1_ip_requirements:
82 type: org.openecomp.datatypes.network.IpRequirements
83 port_pd01_port2_network_role_tag:
87 port_pd01_port1_order:
91 port_pd01_port1_network_role:
95 port_pd01_port2_mac_requirements:
96 type: org.openecomp.datatypes.network.MacRequirements
99 port_pd01_port2_order:
103 port_pd01_port1_vlan_requirements:
108 type: org.openecomp.datatypes.network.VlanRequirements
113 port_pd01_port2_vlan_requirements:
118 type: org.openecomp.datatypes.network.VlanRequirements
119 port_pd01_port2_exCP_naming:
120 type: org.openecomp.datatypes.Naming
123 compute_pd_server_user_data_format:
130 - dependency_pd_server_pd01_port1:
131 capability: tosca.capabilities.Node
132 node: tosca.nodes.Root
133 relationship: tosca.relationships.DependsOn
137 - link_pd_server_pd01_port1:
138 capability: tosca.capabilities.network.Linkable
139 relationship: tosca.relationships.network.LinksTo
143 - dependency_pd_server:
144 capability: tosca.capabilities.Node
145 node: tosca.nodes.Root
146 relationship: tosca.relationships.DependsOn
150 - local_storage_pd_server:
151 capability: tosca.capabilities.Attachment
152 node: tosca.nodes.BlockStorage
153 relationship: tosca.relationships.AttachesTo
157 - dependency_pd_server_pd01_port2:
158 capability: tosca.capabilities.Node
159 node: tosca.nodes.Root
160 relationship: tosca.relationships.DependsOn
164 - link_pd_server_pd01_port2:
165 capability: tosca.capabilities.network.Linkable
166 relationship: tosca.relationships.network.LinksTo
172 type: tosca.capabilities.Scalable
176 disk.read.bytes.rate_pd_server:
177 type: org.openecomp.capabilities.metric.Ceilometer
178 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
182 memory.usage_pd_server:
183 type: org.openecomp.capabilities.metric.Ceilometer
184 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
189 type: org.openecomp.capabilities.metric.Ceilometer
190 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
194 disk.device.usage_pd_server:
195 type: org.openecomp.capabilities.metric.Ceilometer
196 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
201 type: tosca.capabilities.OperatingSystem
205 disk.write.bytes.rate_pd_server:
206 type: org.openecomp.capabilities.metric.Ceilometer
207 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
211 network.outpoing.packets_pd_server_pd01_port2:
212 type: org.openecomp.capabilities.metric.Ceilometer
213 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
217 network.outpoing.packets_pd_server_pd01_port1:
218 type: org.openecomp.capabilities.metric.Ceilometer
219 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
224 type: org.openecomp.capabilities.metric.Ceilometer
225 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
230 type: org.openecomp.capabilities.metric.Ceilometer
231 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
235 disk.device.write.requests.rate_pd_server:
236 type: org.openecomp.capabilities.metric.Ceilometer
237 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
241 disk.read.bytes_pd_server:
242 type: org.openecomp.capabilities.metric.Ceilometer
243 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
247 network.incoming.bytes_pd_server_pd01_port2:
248 type: org.openecomp.capabilities.metric.Ceilometer
249 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
253 network.incoming.bytes_pd_server_pd01_port1:
254 type: org.openecomp.capabilities.metric.Ceilometer
255 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
259 disk.device.read.bytes.rate_pd_server:
260 type: org.openecomp.capabilities.metric.Ceilometer
261 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
266 type: org.openecomp.capabilities.metric.Ceilometer
267 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
271 network.outgoing.bytes_pd_server_pd01_port1:
272 type: org.openecomp.capabilities.metric.Ceilometer
273 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
277 memory.resident_pd_server:
278 type: org.openecomp.capabilities.metric.Ceilometer
279 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
284 type: org.openecomp.capabilities.metric.Ceilometer
285 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
289 network.outgoing.bytes_pd_server_pd01_port2:
290 type: org.openecomp.capabilities.metric.Ceilometer
291 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
296 type: org.openecomp.capabilities.metric.Ceilometer
297 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
301 disk.device.write.bytes.rate_pd_server:
302 type: org.openecomp.capabilities.metric.Ceilometer
303 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
307 disk.device.write.requests_pd_server:
308 type: org.openecomp.capabilities.metric.Ceilometer
309 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
314 type: tosca.capabilities.Endpoint.Admin
318 disk.capacity_pd_server:
319 type: org.openecomp.capabilities.metric.Ceilometer
320 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
324 network.outgoing.packets.rate_pd_server_pd01_port1:
325 type: org.openecomp.capabilities.metric.Ceilometer
326 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
330 disk.device.allocation_pd_server:
331 type: org.openecomp.capabilities.metric.Ceilometer
332 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
336 disk.allocation_pd_server:
337 type: org.openecomp.capabilities.metric.Ceilometer
338 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
342 network.outgoing.packets.rate_pd_server_pd01_port2:
343 type: org.openecomp.capabilities.metric.Ceilometer
344 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
348 forwarder_pd_server_pd01_port1:
349 type: org.openecomp.capabilities.Forwarder
353 network.incoming.packets_pd_server_pd01_port2:
354 type: org.openecomp.capabilities.metric.Ceilometer
355 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
360 type: tosca.capabilities.network.Bindable
364 forwarder_pd_server_pd01_port2:
365 type: org.openecomp.capabilities.Forwarder
369 disk.read.requests_pd_server:
370 type: org.openecomp.capabilities.metric.Ceilometer
371 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
375 network.incoming.packets_pd_server_pd01_port1:
376 type: org.openecomp.capabilities.metric.Ceilometer
377 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
381 feature_pd_server_pd01_port2:
382 type: tosca.capabilities.Node
386 feature_pd_server_pd01_port1:
387 type: tosca.capabilities.Node
392 type: tosca.capabilities.Node
396 disk.usage_pd_server:
397 type: org.openecomp.capabilities.metric.Ceilometer
398 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
402 network.outgoing.bytes.rate_pd_server_pd01_port2:
403 type: org.openecomp.capabilities.metric.Ceilometer
404 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
408 network.outgoing.bytes.rate_pd_server_pd01_port1:
409 type: org.openecomp.capabilities.metric.Ceilometer
410 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
414 disk.write.bytes_pd_server:
415 type: org.openecomp.capabilities.metric.Ceilometer
416 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
420 binding_pd_server_pd01_port1:
421 type: tosca.capabilities.network.Bindable
423 - org.openecomp.resource.cp.nodes.heat.network.contrailV2.VLANSubInterface
427 binding_pd_server_pd01_port2:
428 type: tosca.capabilities.network.Bindable
430 - org.openecomp.resource.cp.nodes.heat.network.contrailV2.VLANSubInterface
434 disk.device.read.requests.rate_pd_server:
435 type: org.openecomp.capabilities.metric.Ceilometer
436 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
440 network.incoming.packets.rate_pd_server_pd01_port1:
441 type: org.openecomp.capabilities.metric.Ceilometer
442 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
446 disk.root.size_pd_server:
447 type: org.openecomp.capabilities.metric.Ceilometer
448 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
452 disk.device.read.bytes_pd_server:
453 type: org.openecomp.capabilities.metric.Ceilometer
454 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
458 disk.device.write.bytes_pd_server:
459 type: org.openecomp.capabilities.metric.Ceilometer
460 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
464 network.incoming.packets.rate_pd_server_pd01_port2:
465 type: org.openecomp.capabilities.metric.Ceilometer
466 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
470 network.incoming.bytes.rate_pd_server_pd01_port1:
471 type: org.openecomp.capabilities.metric.Ceilometer
472 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
476 disk.device.read.requests_pd_server:
477 type: org.openecomp.capabilities.metric.Ceilometer
478 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
482 network.incoming.bytes.rate_pd_server_pd01_port2:
483 type: org.openecomp.capabilities.metric.Ceilometer
484 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
489 type: org.openecomp.capabilities.metric.Ceilometer
490 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
495 type: tosca.capabilities.Container
497 - tosca.nodes.SoftwareComponent
501 disk.write.requests.rate_pd_server:
502 type: org.openecomp.capabilities.metric.Ceilometer
503 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
507 disk.ephemeral.size_pd_server:
508 type: org.openecomp.capabilities.metric.Ceilometer
509 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
513 disk.write.requests_pd_server:
514 type: org.openecomp.capabilities.metric.Ceilometer
515 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
519 disk.device.latency_pd_server:
520 type: org.openecomp.capabilities.metric.Ceilometer
521 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
525 attachment_pd_server_pd01_port2:
526 type: tosca.capabilities.Attachment
530 disk.latency_pd_server:
531 type: org.openecomp.capabilities.metric.Ceilometer
532 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
536 disk.device.capacity_pd_server:
537 type: org.openecomp.capabilities.metric.Ceilometer
538 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
542 attachment_pd_server_pd01_port1:
543 type: tosca.capabilities.Attachment
547 disk.device.iops_pd_server:
548 type: org.openecomp.capabilities.metric.Ceilometer
549 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.