1 tosca_definitions_version: tosca_simple_yaml_1_0_0
3 template_name: GlobalSubstitutionTypes
5 - openecomp_heat_index:
6 file: openecomp-heat/_index.yml
8 org.openecomp.resource.abstract.nodes.heat.nested-pcm_v0.1:
9 derived_from: org.openecomp.resource.abstract.nodes.AbstractSubstitute
13 description: flavor name of PCRF CM instance
16 availabilityzone_name:
18 description: availabilityzone name
23 description: CPS network gateway
28 description: PCRF CM image name
33 description: PCRF CM image name
38 description: the name of security group
43 description: CPS network ip
48 description: flavor name of PCRF CM instance
53 description: PCRF CM server name
58 description: CPS Cluman Cinder Volume
63 description: PCRF CM server name
68 description: CPS network name
73 description: CPS network mask
78 description: OAM network ip
83 description: CPS network mask
88 description: OAM network name
94 description: the pcm nova service id
98 description: the pcm nova service id
101 - dependency_server_pcm:
102 capability: tosca.capabilities.Node
103 node: tosca.nodes.Root
104 relationship: tosca.relationships.DependsOn
108 - local_storage_server_pcm:
109 capability: tosca.capabilities.Attachment
110 node: tosca.nodes.BlockStorage
111 relationship: tosca.relationships.AttachesTo
115 - dependency_pcm_port_1:
116 capability: tosca.capabilities.Node
117 node: tosca.nodes.Root
118 relationship: tosca.relationships.DependsOn
123 capability: tosca.capabilities.network.Linkable
124 relationship: tosca.relationships.network.LinksTo
128 - dependency_server_pd:
129 capability: tosca.capabilities.Node
130 node: tosca.nodes.Root
131 relationship: tosca.relationships.DependsOn
135 - local_storage_server_pd:
136 capability: tosca.capabilities.Attachment
137 node: tosca.nodes.BlockStorage
138 relationship: tosca.relationships.AttachesTo
142 - dependency_pcm_port_0:
143 capability: tosca.capabilities.Node
144 node: tosca.nodes.Root
145 relationship: tosca.relationships.DependsOn
150 capability: tosca.capabilities.network.Linkable
151 relationship: tosca.relationships.network.LinksTo
156 network.incoming.packets.rate_pcm_port_0:
157 type: org.openecomp.capabilities.metric.Ceilometer
158 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
163 type: org.openecomp.capabilities.metric.Ceilometer
164 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
168 disk.device.read.bytes.rate_server_pd:
169 type: org.openecomp.capabilities.metric.Ceilometer
170 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
174 network.incoming.packets.rate_pcm_port_1:
175 type: org.openecomp.capabilities.metric.Ceilometer
176 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
181 type: org.openecomp.capabilities.metric.Ceilometer
182 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
186 network.outpoing.packets_pcm_port_1:
187 type: org.openecomp.capabilities.metric.Ceilometer
188 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
192 network.outpoing.packets_pcm_port_0:
193 type: org.openecomp.capabilities.metric.Ceilometer
194 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
198 disk.device.read.requests_server_pd:
199 type: org.openecomp.capabilities.metric.Ceilometer
200 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
204 disk.device.iops_server_pcm:
205 type: org.openecomp.capabilities.metric.Ceilometer
206 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
210 disk.device.allocation_server_pd:
211 type: org.openecomp.capabilities.metric.Ceilometer
212 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
216 disk.allocation_server_pcm:
217 type: org.openecomp.capabilities.metric.Ceilometer
218 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
222 memory.usage_server_pd:
223 type: org.openecomp.capabilities.metric.Ceilometer
224 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
228 disk.read.bytes.rate_server_pd:
229 type: org.openecomp.capabilities.metric.Ceilometer
230 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
234 disk.usage_server_pcm:
235 type: org.openecomp.capabilities.metric.Ceilometer
236 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
240 disk.root.size_server_pcm:
241 type: org.openecomp.capabilities.metric.Ceilometer
242 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
247 type: org.openecomp.capabilities.metric.Ceilometer
248 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
252 disk.device.latency_server_pcm:
253 type: org.openecomp.capabilities.metric.Ceilometer
254 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
258 network.incoming.bytes_pcm_port_0:
259 type: org.openecomp.capabilities.metric.Ceilometer
260 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
264 disk.device.write.requests_server_pd:
265 type: org.openecomp.capabilities.metric.Ceilometer
266 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
270 network.incoming.bytes_pcm_port_1:
271 type: org.openecomp.capabilities.metric.Ceilometer
272 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
277 type: tosca.capabilities.network.Bindable
279 - org.openecomp.resource.cp.nodes.heat.network.contrailV2.VLANSubInterface
283 memory.usage_server_pcm:
284 type: org.openecomp.capabilities.metric.Ceilometer
285 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
290 type: tosca.capabilities.network.Bindable
292 - org.openecomp.resource.cp.nodes.heat.network.contrailV2.VLANSubInterface
296 disk.read.requests_server_pcm:
297 type: org.openecomp.capabilities.metric.Ceilometer
298 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
302 disk.read.bytes_server_pcm:
303 type: org.openecomp.capabilities.metric.Ceilometer
304 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
308 network.outgoing.packets.rate_pcm_port_0:
309 type: org.openecomp.capabilities.metric.Ceilometer
310 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
314 network.outgoing.packets.rate_pcm_port_1:
315 type: org.openecomp.capabilities.metric.Ceilometer
316 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
321 type: tosca.capabilities.Node
325 network.outgoing.bytes_pcm_port_0:
326 type: org.openecomp.capabilities.metric.Ceilometer
327 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
331 disk.device.read.bytes_server_pcm:
332 type: org.openecomp.capabilities.metric.Ceilometer
333 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
337 disk.read.bytes_server_pd:
338 type: org.openecomp.capabilities.metric.Ceilometer
339 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
344 type: tosca.capabilities.Node
348 network.outgoing.bytes_pcm_port_1:
349 type: org.openecomp.capabilities.metric.Ceilometer
350 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
354 attachment_pcm_port_0:
355 type: tosca.capabilities.Attachment
359 attachment_pcm_port_1:
360 type: tosca.capabilities.Attachment
364 disk.device.read.bytes_server_pd:
365 type: org.openecomp.capabilities.metric.Ceilometer
366 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
370 disk.device.read.requests.rate_server_pcm:
371 type: org.openecomp.capabilities.metric.Ceilometer
372 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
377 type: org.openecomp.capabilities.metric.Ceilometer
378 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
382 disk.write.bytes_server_pcm:
383 type: org.openecomp.capabilities.metric.Ceilometer
384 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
389 type: tosca.capabilities.Container
391 - tosca.nodes.SoftwareComponent
395 disk.read.bytes.rate_server_pcm:
396 type: org.openecomp.capabilities.metric.Ceilometer
397 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
402 type: org.openecomp.capabilities.metric.Ceilometer
403 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
407 disk.device.allocation_server_pcm:
408 type: org.openecomp.capabilities.metric.Ceilometer
409 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
413 disk.ephemeral.size_server_pd:
414 type: org.openecomp.capabilities.metric.Ceilometer
415 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
419 disk.write.requests.rate_server_pd:
420 type: org.openecomp.capabilities.metric.Ceilometer
421 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
426 type: tosca.capabilities.Scalable
431 type: org.openecomp.capabilities.metric.Ceilometer
432 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
436 disk.write.requests_server_pd:
437 type: org.openecomp.capabilities.metric.Ceilometer
438 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
443 type: tosca.capabilities.Container
445 - tosca.nodes.SoftwareComponent
449 cpu.delta_server_pcm:
450 type: org.openecomp.capabilities.metric.Ceilometer
451 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
456 type: tosca.capabilities.network.Bindable
460 disk.device.capacity_server_pcm:
461 type: org.openecomp.capabilities.metric.Ceilometer
462 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
467 type: tosca.capabilities.network.Bindable
471 disk.device.write.requests.rate_server_pcm:
472 type: org.openecomp.capabilities.metric.Ceilometer
473 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
477 disk.latency_server_pcm:
478 type: org.openecomp.capabilities.metric.Ceilometer
479 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
483 disk.device.read.requests_server_pcm:
484 type: org.openecomp.capabilities.metric.Ceilometer
485 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
490 type: tosca.capabilities.Node
494 disk.root.size_server_pd:
495 type: org.openecomp.capabilities.metric.Ceilometer
496 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
500 disk.device.read.requests.rate_server_pd:
501 type: org.openecomp.capabilities.metric.Ceilometer
502 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
506 disk.write.bytes.rate_server_pcm:
507 type: org.openecomp.capabilities.metric.Ceilometer
508 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
512 disk.device.write.bytes_server_pd:
513 type: org.openecomp.capabilities.metric.Ceilometer
514 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
519 type: org.openecomp.capabilities.metric.Ceilometer
520 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
524 memory.resident_server_pd:
525 type: org.openecomp.capabilities.metric.Ceilometer
526 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
530 disk.write.requests_server_pcm:
531 type: org.openecomp.capabilities.metric.Ceilometer
532 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
537 type: org.openecomp.capabilities.metric.Ceilometer
538 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
542 memory.resident_server_pcm:
543 type: org.openecomp.capabilities.metric.Ceilometer
544 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
548 disk.device.write.requests_server_pcm:
549 type: org.openecomp.capabilities.metric.Ceilometer
550 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
554 disk.usage_server_pd:
555 type: org.openecomp.capabilities.metric.Ceilometer
556 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
560 disk.device.usage_server_pcm:
561 type: org.openecomp.capabilities.metric.Ceilometer
562 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
566 disk.capacity_server_pd:
567 type: org.openecomp.capabilities.metric.Ceilometer
568 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
573 type: tosca.capabilities.Endpoint.Admin
577 disk.device.capacity_server_pd:
578 type: org.openecomp.capabilities.metric.Ceilometer
579 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
583 disk.allocation_server_pd:
584 type: org.openecomp.capabilities.metric.Ceilometer
585 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
589 disk.device.write.bytes_server_pcm:
590 type: org.openecomp.capabilities.metric.Ceilometer
591 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
595 disk.ephemeral.size_server_pcm:
596 type: org.openecomp.capabilities.metric.Ceilometer
597 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
601 disk.device.usage_server_pd:
602 type: org.openecomp.capabilities.metric.Ceilometer
603 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
607 disk.capacity_server_pcm:
608 type: org.openecomp.capabilities.metric.Ceilometer
609 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
614 type: tosca.capabilities.OperatingSystem
619 type: tosca.capabilities.Endpoint.Admin
624 type: org.openecomp.capabilities.metric.Ceilometer
625 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
629 disk.iops_server_pcm:
630 type: org.openecomp.capabilities.metric.Ceilometer
631 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
636 type: org.openecomp.capabilities.metric.Ceilometer
637 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
641 disk.latency_server_pd:
642 type: org.openecomp.capabilities.metric.Ceilometer
643 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
647 disk.device.write.bytes.rate_server_pd:
648 type: org.openecomp.capabilities.metric.Ceilometer
649 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
653 disk.device.read.bytes.rate_server_pcm:
654 type: org.openecomp.capabilities.metric.Ceilometer
655 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
659 disk.write.requests.rate_server_pcm:
660 type: org.openecomp.capabilities.metric.Ceilometer
661 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
665 disk.device.write.bytes.rate_server_pcm:
666 type: org.openecomp.capabilities.metric.Ceilometer
667 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
671 disk.device.iops_server_pd:
672 type: org.openecomp.capabilities.metric.Ceilometer
673 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
677 disk.read.requests_server_pd:
678 type: org.openecomp.capabilities.metric.Ceilometer
679 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
683 network.outgoing.bytes.rate_pcm_port_1:
684 type: org.openecomp.capabilities.metric.Ceilometer
685 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
689 network.incoming.packets_pcm_port_0:
690 type: org.openecomp.capabilities.metric.Ceilometer
691 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
696 type: tosca.capabilities.OperatingSystem
700 disk.device.latency_server_pd:
701 type: org.openecomp.capabilities.metric.Ceilometer
702 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
706 network.outgoing.bytes.rate_pcm_port_0:
707 type: org.openecomp.capabilities.metric.Ceilometer
708 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
712 network.incoming.packets_pcm_port_1:
713 type: org.openecomp.capabilities.metric.Ceilometer
714 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
719 type: tosca.capabilities.Scalable
724 type: org.openecomp.capabilities.metric.Ceilometer
725 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
729 disk.write.bytes_server_pd:
730 type: org.openecomp.capabilities.metric.Ceilometer
731 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
735 disk.write.bytes.rate_server_pd:
736 type: org.openecomp.capabilities.metric.Ceilometer
737 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
742 type: tosca.capabilities.Node
746 network.incoming.bytes.rate_pcm_port_0:
747 type: org.openecomp.capabilities.metric.Ceilometer
748 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
752 disk.device.write.requests.rate_server_pd:
753 type: org.openecomp.capabilities.metric.Ceilometer
754 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
759 type: org.openecomp.capabilities.metric.Ceilometer
760 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
764 network.incoming.bytes.rate_pcm_port_1:
765 type: org.openecomp.capabilities.metric.Ceilometer
766 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.