1 tosca_definitions_version: tosca_simple_yaml_1_0_0
3 template_name: GlobalSubstitutionTypes
5 - openecomp_heat_index:
6 file: openecomp-heat/_index.yml
8 org.openecomp.resource.abstract.nodes.heat.pcm_server:
9 derived_from: org.openecomp.resource.abstract.nodes.VFC
16 availabilityzone_name:
18 description: availabilityzone name
23 description: CPS network gateway
28 description: PCRF CM image name
33 description: the name of security group
38 description: CPS network ip
43 description: flavor name of PCRF CM instance
53 description: user_data_format
58 description: CPS Cluman Cinder Volume
63 description: PCRF CM server name
68 description: CPS network name
73 description: CPS network mask
78 description: OAM network ip
83 description: CPS network mask
88 description: OAM network name
94 description: the pcm nova service id
97 - dependency_pcm_port_1:
98 capability: tosca.capabilities.Node
99 node: tosca.nodes.Root
100 relationship: tosca.relationships.DependsOn
105 capability: tosca.capabilities.network.Linkable
106 relationship: tosca.relationships.network.LinksTo
110 - dependency_server_pcm:
111 capability: tosca.capabilities.Node
112 node: tosca.nodes.Root
113 relationship: tosca.relationships.DependsOn
117 - local_storage_server_pcm:
118 capability: tosca.capabilities.Attachment
119 node: tosca.nodes.BlockStorage
120 relationship: tosca.relationships.AttachesTo
124 - dependency_pcm_port_0:
125 capability: tosca.capabilities.Node
126 node: tosca.nodes.Root
127 relationship: tosca.relationships.DependsOn
132 capability: tosca.capabilities.network.Linkable
133 relationship: tosca.relationships.network.LinksTo
138 network.incoming.packets.rate_pcm_port_0:
139 type: org.openecomp.capabilities.metric.Ceilometer
140 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
145 type: org.openecomp.capabilities.metric.Ceilometer
146 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
150 network.incoming.packets.rate_pcm_port_1:
151 type: org.openecomp.capabilities.metric.Ceilometer
152 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
156 network.outpoing.packets_pcm_port_1:
157 type: org.openecomp.capabilities.metric.Ceilometer
158 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
163 type: org.openecomp.capabilities.metric.Ceilometer
164 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
168 disk.write.requests_server_pcm:
169 type: org.openecomp.capabilities.metric.Ceilometer
170 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
174 network.outpoing.packets_pcm_port_0:
175 type: org.openecomp.capabilities.metric.Ceilometer
176 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
180 disk.device.iops_server_pcm:
181 type: org.openecomp.capabilities.metric.Ceilometer
182 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
186 memory.resident_server_pcm:
187 type: org.openecomp.capabilities.metric.Ceilometer
188 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
192 disk.device.write.requests_server_pcm:
193 type: org.openecomp.capabilities.metric.Ceilometer
194 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
198 disk.device.usage_server_pcm:
199 type: org.openecomp.capabilities.metric.Ceilometer
200 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
204 disk.allocation_server_pcm:
205 type: org.openecomp.capabilities.metric.Ceilometer
206 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
210 disk.usage_server_pcm:
211 type: org.openecomp.capabilities.metric.Ceilometer
212 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
216 disk.device.write.bytes_server_pcm:
217 type: org.openecomp.capabilities.metric.Ceilometer
218 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
222 disk.root.size_server_pcm:
223 type: org.openecomp.capabilities.metric.Ceilometer
224 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
228 disk.ephemeral.size_server_pcm:
229 type: org.openecomp.capabilities.metric.Ceilometer
230 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
234 disk.device.latency_server_pcm:
235 type: org.openecomp.capabilities.metric.Ceilometer
236 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
240 network.incoming.bytes_pcm_port_0:
241 type: org.openecomp.capabilities.metric.Ceilometer
242 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
246 network.incoming.bytes_pcm_port_1:
247 type: org.openecomp.capabilities.metric.Ceilometer
248 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
253 type: tosca.capabilities.network.Bindable
255 - org.openecomp.resource.cp.nodes.heat.network.contrailV2.VLANSubInterface
260 type: tosca.capabilities.network.Bindable
262 - org.openecomp.resource.cp.nodes.heat.network.contrailV2.VLANSubInterface
266 memory.usage_server_pcm:
267 type: org.openecomp.capabilities.metric.Ceilometer
268 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
272 disk.read.requests_server_pcm:
273 type: org.openecomp.capabilities.metric.Ceilometer
274 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
278 disk.capacity_server_pcm:
279 type: org.openecomp.capabilities.metric.Ceilometer
280 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
285 type: tosca.capabilities.OperatingSystem
289 disk.read.bytes_server_pcm:
290 type: org.openecomp.capabilities.metric.Ceilometer
291 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
295 network.outgoing.packets.rate_pcm_port_0:
296 type: org.openecomp.capabilities.metric.Ceilometer
297 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
301 network.outgoing.packets.rate_pcm_port_1:
302 type: org.openecomp.capabilities.metric.Ceilometer
303 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
308 type: tosca.capabilities.Node
312 network.outgoing.bytes_pcm_port_0:
313 type: org.openecomp.capabilities.metric.Ceilometer
314 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
318 disk.device.read.bytes_server_pcm:
319 type: org.openecomp.capabilities.metric.Ceilometer
320 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
325 type: tosca.capabilities.Node
329 network.outgoing.bytes_pcm_port_1:
330 type: org.openecomp.capabilities.metric.Ceilometer
331 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
335 attachment_pcm_port_0:
336 type: tosca.capabilities.Attachment
340 attachment_pcm_port_1:
341 type: tosca.capabilities.Attachment
346 type: tosca.capabilities.Endpoint.Admin
350 disk.device.read.requests.rate_server_pcm:
351 type: org.openecomp.capabilities.metric.Ceilometer
352 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
357 type: org.openecomp.capabilities.metric.Ceilometer
358 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
362 disk.write.bytes_server_pcm:
363 type: org.openecomp.capabilities.metric.Ceilometer
364 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
368 disk.iops_server_pcm:
369 type: org.openecomp.capabilities.metric.Ceilometer
370 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
374 disk.read.bytes.rate_server_pcm:
375 type: org.openecomp.capabilities.metric.Ceilometer
376 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
380 disk.device.allocation_server_pcm:
381 type: org.openecomp.capabilities.metric.Ceilometer
382 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
387 type: tosca.capabilities.Scalable
391 disk.device.read.bytes.rate_server_pcm:
392 type: org.openecomp.capabilities.metric.Ceilometer
393 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
398 type: org.openecomp.capabilities.metric.Ceilometer
399 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
403 disk.write.requests.rate_server_pcm:
404 type: org.openecomp.capabilities.metric.Ceilometer
405 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
409 disk.device.write.bytes.rate_server_pcm:
410 type: org.openecomp.capabilities.metric.Ceilometer
411 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
416 type: tosca.capabilities.Container
418 - tosca.nodes.SoftwareComponent
422 cpu.delta_server_pcm:
423 type: org.openecomp.capabilities.metric.Ceilometer
424 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
428 network.outgoing.bytes.rate_pcm_port_1:
429 type: org.openecomp.capabilities.metric.Ceilometer
430 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
434 network.incoming.packets_pcm_port_0:
435 type: org.openecomp.capabilities.metric.Ceilometer
436 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
441 type: tosca.capabilities.network.Bindable
445 network.outgoing.bytes.rate_pcm_port_0:
446 type: org.openecomp.capabilities.metric.Ceilometer
447 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
451 disk.device.capacity_server_pcm:
452 type: org.openecomp.capabilities.metric.Ceilometer
453 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
457 network.incoming.packets_pcm_port_1:
458 type: org.openecomp.capabilities.metric.Ceilometer
459 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
464 type: org.openecomp.capabilities.metric.Ceilometer
465 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
469 disk.device.write.requests.rate_server_pcm:
470 type: org.openecomp.capabilities.metric.Ceilometer
471 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
475 disk.latency_server_pcm:
476 type: org.openecomp.capabilities.metric.Ceilometer
477 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
481 disk.device.read.requests_server_pcm:
482 type: org.openecomp.capabilities.metric.Ceilometer
483 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
488 type: tosca.capabilities.Node
492 network.incoming.bytes.rate_pcm_port_0:
493 type: org.openecomp.capabilities.metric.Ceilometer
494 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
498 disk.write.bytes.rate_server_pcm:
499 type: org.openecomp.capabilities.metric.Ceilometer
500 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
504 network.incoming.bytes.rate_pcm_port_1:
505 type: org.openecomp.capabilities.metric.Ceilometer
506 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
510 org.openecomp.resource.abstract.nodes.heat.oam_server:
511 derived_from: org.openecomp.resource.abstract.nodes.VFC
513 availabilityzone_name:
515 description: availabilityzone name
520 description: CPS network gateway
525 description: flavor name of PCRF CM instance
530 description: the name of security group
535 description: CPS network ip
540 description: oam server name
545 description: CPS Cluman Cinder Volume
550 description: oam image name
555 description: CPS network name
560 description: CPS network mask
565 description: OAM network ip
570 description: CPS network mask
575 description: OAM network name
581 description: the oam nova service id
584 - dependency_server_oam:
585 capability: tosca.capabilities.Node
586 node: tosca.nodes.Root
587 relationship: tosca.relationships.DependsOn
591 - local_storage_server_oam:
592 capability: tosca.capabilities.Attachment
593 node: tosca.nodes.BlockStorage
594 relationship: tosca.relationships.AttachesTo
598 - dependency_pcm_port_1:
599 capability: tosca.capabilities.Node
600 node: tosca.nodes.Root
601 relationship: tosca.relationships.DependsOn
606 capability: tosca.capabilities.network.Linkable
607 relationship: tosca.relationships.network.LinksTo
611 - dependency_pcm_port_0:
612 capability: tosca.capabilities.Node
613 node: tosca.nodes.Root
614 relationship: tosca.relationships.DependsOn
619 capability: tosca.capabilities.network.Linkable
620 relationship: tosca.relationships.network.LinksTo
626 type: org.openecomp.capabilities.metric.Ceilometer
627 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
631 network.incoming.packets.rate_pcm_port_0:
632 type: org.openecomp.capabilities.metric.Ceilometer
633 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
637 network.incoming.packets.rate_pcm_port_1:
638 type: org.openecomp.capabilities.metric.Ceilometer
639 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
643 network.outpoing.packets_pcm_port_1:
644 type: org.openecomp.capabilities.metric.Ceilometer
645 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
650 type: org.openecomp.capabilities.metric.Ceilometer
651 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
655 network.outpoing.packets_pcm_port_0:
656 type: org.openecomp.capabilities.metric.Ceilometer
657 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
661 disk.write.requests_server_oam:
662 type: org.openecomp.capabilities.metric.Ceilometer
663 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
667 memory.resident_server_oam:
668 type: org.openecomp.capabilities.metric.Ceilometer
669 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
673 disk.device.iops_server_oam:
674 type: org.openecomp.capabilities.metric.Ceilometer
675 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
679 disk.device.write.requests_server_oam:
680 type: org.openecomp.capabilities.metric.Ceilometer
681 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
685 disk.allocation_server_oam:
686 type: org.openecomp.capabilities.metric.Ceilometer
687 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
691 disk.device.usage_server_oam:
692 type: org.openecomp.capabilities.metric.Ceilometer
693 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
697 disk.usage_server_oam:
698 type: org.openecomp.capabilities.metric.Ceilometer
699 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
703 disk.device.write.bytes_server_oam:
704 type: org.openecomp.capabilities.metric.Ceilometer
705 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
709 network.incoming.bytes_pcm_port_0:
710 type: org.openecomp.capabilities.metric.Ceilometer
711 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
715 disk.ephemeral.size_server_oam:
716 type: org.openecomp.capabilities.metric.Ceilometer
717 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
721 disk.device.latency_server_oam:
722 type: org.openecomp.capabilities.metric.Ceilometer
723 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
727 disk.root.size_server_oam:
728 type: org.openecomp.capabilities.metric.Ceilometer
729 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
733 memory.usage_server_oam:
734 type: org.openecomp.capabilities.metric.Ceilometer
735 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
739 network.incoming.bytes_pcm_port_1:
740 type: org.openecomp.capabilities.metric.Ceilometer
741 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
746 type: tosca.capabilities.network.Bindable
748 - org.openecomp.resource.cp.nodes.heat.network.contrailV2.VLANSubInterface
753 type: tosca.capabilities.network.Bindable
755 - org.openecomp.resource.cp.nodes.heat.network.contrailV2.VLANSubInterface
759 disk.read.bytes_server_oam:
760 type: org.openecomp.capabilities.metric.Ceilometer
761 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
766 type: tosca.capabilities.OperatingSystem
770 disk.read.requests_server_oam:
771 type: org.openecomp.capabilities.metric.Ceilometer
772 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
776 disk.capacity_server_oam:
777 type: org.openecomp.capabilities.metric.Ceilometer
778 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
782 network.outgoing.packets.rate_pcm_port_0:
783 type: org.openecomp.capabilities.metric.Ceilometer
784 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
788 network.outgoing.packets.rate_pcm_port_1:
789 type: org.openecomp.capabilities.metric.Ceilometer
790 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
795 type: tosca.capabilities.Node
799 network.outgoing.bytes_pcm_port_0:
800 type: org.openecomp.capabilities.metric.Ceilometer
801 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
806 type: tosca.capabilities.Node
810 network.outgoing.bytes_pcm_port_1:
811 type: org.openecomp.capabilities.metric.Ceilometer
812 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
816 attachment_pcm_port_0:
817 type: tosca.capabilities.Attachment
821 attachment_pcm_port_1:
822 type: tosca.capabilities.Attachment
826 disk.device.read.bytes_server_oam:
827 type: org.openecomp.capabilities.metric.Ceilometer
828 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
833 type: tosca.capabilities.Endpoint.Admin
837 disk.device.read.requests.rate_server_oam:
838 type: org.openecomp.capabilities.metric.Ceilometer
839 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
844 type: org.openecomp.capabilities.metric.Ceilometer
845 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
849 disk.read.bytes.rate_server_oam:
850 type: org.openecomp.capabilities.metric.Ceilometer
851 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
855 disk.write.bytes_server_oam:
856 type: org.openecomp.capabilities.metric.Ceilometer
857 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
861 disk.iops_server_oam:
862 type: org.openecomp.capabilities.metric.Ceilometer
863 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
867 disk.device.allocation_server_oam:
868 type: org.openecomp.capabilities.metric.Ceilometer
869 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
873 disk.write.requests.rate_server_oam:
874 type: org.openecomp.capabilities.metric.Ceilometer
875 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
880 type: tosca.capabilities.Scalable
884 disk.device.read.bytes.rate_server_oam:
885 type: org.openecomp.capabilities.metric.Ceilometer
886 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
891 type: org.openecomp.capabilities.metric.Ceilometer
892 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
896 cpu.delta_server_oam:
897 type: org.openecomp.capabilities.metric.Ceilometer
898 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
903 type: tosca.capabilities.Container
905 - tosca.nodes.SoftwareComponent
909 disk.device.write.bytes.rate_server_oam:
910 type: org.openecomp.capabilities.metric.Ceilometer
911 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
915 network.outgoing.bytes.rate_pcm_port_1:
916 type: org.openecomp.capabilities.metric.Ceilometer
917 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
921 network.incoming.packets_pcm_port_0:
922 type: org.openecomp.capabilities.metric.Ceilometer
923 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
928 type: tosca.capabilities.network.Bindable
932 network.outgoing.bytes.rate_pcm_port_0:
933 type: org.openecomp.capabilities.metric.Ceilometer
934 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
938 disk.device.capacity_server_oam:
939 type: org.openecomp.capabilities.metric.Ceilometer
940 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
944 network.incoming.packets_pcm_port_1:
945 type: org.openecomp.capabilities.metric.Ceilometer
946 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
950 disk.latency_server_oam:
951 type: org.openecomp.capabilities.metric.Ceilometer
952 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
957 type: org.openecomp.capabilities.metric.Ceilometer
958 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
962 disk.device.read.requests_server_oam:
963 type: org.openecomp.capabilities.metric.Ceilometer
964 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
968 disk.device.write.requests.rate_server_oam:
969 type: org.openecomp.capabilities.metric.Ceilometer
970 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
975 type: tosca.capabilities.Node
979 network.incoming.bytes.rate_pcm_port_0:
980 type: org.openecomp.capabilities.metric.Ceilometer
981 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
985 disk.write.bytes.rate_server_oam:
986 type: org.openecomp.capabilities.metric.Ceilometer
987 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
991 network.incoming.bytes.rate_pcm_port_1:
992 type: org.openecomp.capabilities.metric.Ceilometer
993 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
997 org.openecomp.resource.abstract.nodes.compute:
998 derived_from: org.openecomp.resource.abstract.nodes.VFC
1000 compute_compute_user_data_format:
1012 description: Index value of this substitution service template runtime instance
1017 - greater_or_equal: 0
1018 compute_compute_metadata:
1024 compute_compute_name:
1034 compute_compute_config_drive:
1041 compute_instance_name:
1047 - dependency_compute:
1048 capability: tosca.capabilities.Node
1049 node: tosca.nodes.Root
1050 relationship: tosca.relationships.DependsOn
1054 - local_storage_compute:
1055 capability: tosca.capabilities.Attachment
1056 node: tosca.nodes.BlockStorage
1057 relationship: tosca.relationships.AttachesTo
1062 disk.device.usage_compute:
1063 type: org.openecomp.capabilities.metric.Ceilometer
1064 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1068 disk.write.requests_compute:
1069 type: org.openecomp.capabilities.metric.Ceilometer
1070 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1075 type: org.openecomp.capabilities.metric.Ceilometer
1076 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1080 disk.ephemeral.size_compute:
1081 type: org.openecomp.capabilities.metric.Ceilometer
1082 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1086 disk.device.read.bytes.rate_compute:
1087 type: org.openecomp.capabilities.metric.Ceilometer
1088 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1092 disk.latency_compute:
1093 type: org.openecomp.capabilities.metric.Ceilometer
1094 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1098 memory.resident_compute:
1099 type: org.openecomp.capabilities.metric.Ceilometer
1100 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1105 type: org.openecomp.capabilities.metric.Ceilometer
1106 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1111 type: org.openecomp.capabilities.metric.Ceilometer
1112 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1116 disk.root.size_compute:
1117 type: org.openecomp.capabilities.metric.Ceilometer
1118 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1122 disk.write.requests.rate_compute:
1123 type: org.openecomp.capabilities.metric.Ceilometer
1124 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1128 disk.read.requests_compute:
1129 type: org.openecomp.capabilities.metric.Ceilometer
1130 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1134 disk.device.read.requests.rate_compute:
1135 type: org.openecomp.capabilities.metric.Ceilometer
1136 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1140 disk.read.bytes_compute:
1141 type: org.openecomp.capabilities.metric.Ceilometer
1142 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1146 disk.device.read.bytes_compute:
1147 type: org.openecomp.capabilities.metric.Ceilometer
1148 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1152 disk.write.bytes_compute:
1153 type: org.openecomp.capabilities.metric.Ceilometer
1154 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1159 type: org.openecomp.capabilities.metric.Ceilometer
1160 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1165 type: tosca.capabilities.OperatingSystem
1169 disk.write.bytes.rate_compute:
1170 type: org.openecomp.capabilities.metric.Ceilometer
1171 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1176 type: org.openecomp.capabilities.metric.Ceilometer
1177 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1181 disk.capacity_compute:
1182 type: org.openecomp.capabilities.metric.Ceilometer
1183 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1188 type: org.openecomp.capabilities.metric.Ceilometer
1189 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1193 disk.read.bytes.rate_compute:
1194 type: org.openecomp.capabilities.metric.Ceilometer
1195 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1199 disk.device.latency_compute:
1200 type: org.openecomp.capabilities.metric.Ceilometer
1201 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1205 disk.device.write.requests_compute:
1206 type: org.openecomp.capabilities.metric.Ceilometer
1207 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1211 disk.device.iops_compute:
1212 type: org.openecomp.capabilities.metric.Ceilometer
1213 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1217 disk.device.write.requests.rate_compute:
1218 type: org.openecomp.capabilities.metric.Ceilometer
1219 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1224 type: tosca.capabilities.Endpoint.Admin
1228 memory.usage_compute:
1229 type: org.openecomp.capabilities.metric.Ceilometer
1230 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1235 type: tosca.capabilities.Container
1237 - tosca.nodes.SoftwareComponent
1242 type: tosca.capabilities.Node
1246 disk.device.write.bytes_compute:
1247 type: org.openecomp.capabilities.metric.Ceilometer
1248 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1253 type: org.openecomp.capabilities.metric.Ceilometer
1254 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1258 disk.device.write.bytes.rate_compute:
1259 type: org.openecomp.capabilities.metric.Ceilometer
1260 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1265 type: tosca.capabilities.Scalable
1269 disk.device.read.requests_compute:
1270 type: org.openecomp.capabilities.metric.Ceilometer
1271 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1275 disk.allocation_compute:
1276 type: org.openecomp.capabilities.metric.Ceilometer
1277 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1281 disk.device.capacity_compute:
1282 type: org.openecomp.capabilities.metric.Ceilometer
1283 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1287 disk.device.allocation_compute:
1288 type: org.openecomp.capabilities.metric.Ceilometer
1289 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1294 type: org.openecomp.capabilities.metric.Ceilometer
1295 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1300 type: tosca.capabilities.network.Bindable