1 tosca_definitions_version: tosca_simple_yaml_1_0_0
3 template_name: GlobalSubstitutionTypes
5 - openecomp_heat_index:
6 file: openecomp-heat/_index.yml
8 org.openecomp.resource.abstract.nodes.heat.pcm_server:
9 derived_from: org.openecomp.resource.abstract.nodes.VFC
13 description: UID of OAM network
18 description: UID of OAM network
21 availabilityzone_name:
23 description: availabilityzone name
28 description: CPS network gateway
33 description: PCRF CM image name
38 description: the name of security group
43 description: CPS network ip
48 description: flavor name of PCRF CM instance
53 description: CPS Cluman Cinder Volume
58 description: PCRF CM server name
63 description: CPS network name
68 description: CPS network mask
73 description: OAM network ip
78 description: CPS network mask
83 description: OAM network name
89 description: the pcm nova service id
92 - dependency_pcm_port_1:
93 capability: tosca.capabilities.Node
94 node: tosca.nodes.Root
95 relationship: tosca.relationships.DependsOn
100 capability: tosca.capabilities.network.Linkable
101 relationship: tosca.relationships.network.LinksTo
105 - dependency_server_pcm:
106 capability: tosca.capabilities.Node
107 node: tosca.nodes.Root
108 relationship: tosca.relationships.DependsOn
112 - local_storage_server_pcm:
113 capability: tosca.capabilities.Attachment
114 node: tosca.nodes.BlockStorage
115 relationship: tosca.relationships.AttachesTo
119 - dependency_pcm_port_0:
120 capability: tosca.capabilities.Node
121 node: tosca.nodes.Root
122 relationship: tosca.relationships.DependsOn
127 capability: tosca.capabilities.network.Linkable
128 relationship: tosca.relationships.network.LinksTo
133 network.incoming.packets.rate_pcm_port_0:
134 type: org.openecomp.capabilities.metric.Ceilometer
135 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
140 type: org.openecomp.capabilities.metric.Ceilometer
141 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
145 network.incoming.packets.rate_pcm_port_1:
146 type: org.openecomp.capabilities.metric.Ceilometer
147 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
151 network.outpoing.packets_pcm_port_1:
152 type: org.openecomp.capabilities.metric.Ceilometer
153 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
158 type: org.openecomp.capabilities.metric.Ceilometer
159 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
163 disk.write.requests_server_pcm:
164 type: org.openecomp.capabilities.metric.Ceilometer
165 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
169 network.outpoing.packets_pcm_port_0:
170 type: org.openecomp.capabilities.metric.Ceilometer
171 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
175 disk.device.iops_server_pcm:
176 type: org.openecomp.capabilities.metric.Ceilometer
177 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
181 memory.resident_server_pcm:
182 type: org.openecomp.capabilities.metric.Ceilometer
183 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
187 disk.device.write.requests_server_pcm:
188 type: org.openecomp.capabilities.metric.Ceilometer
189 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
193 disk.device.usage_server_pcm:
194 type: org.openecomp.capabilities.metric.Ceilometer
195 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
199 disk.allocation_server_pcm:
200 type: org.openecomp.capabilities.metric.Ceilometer
201 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
205 disk.usage_server_pcm:
206 type: org.openecomp.capabilities.metric.Ceilometer
207 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
211 disk.device.write.bytes_server_pcm:
212 type: org.openecomp.capabilities.metric.Ceilometer
213 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
217 disk.root.size_server_pcm:
218 type: org.openecomp.capabilities.metric.Ceilometer
219 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
223 disk.ephemeral.size_server_pcm:
224 type: org.openecomp.capabilities.metric.Ceilometer
225 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
229 disk.device.latency_server_pcm:
230 type: org.openecomp.capabilities.metric.Ceilometer
231 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
235 network.incoming.bytes_pcm_port_0:
236 type: org.openecomp.capabilities.metric.Ceilometer
237 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
241 network.incoming.bytes_pcm_port_1:
242 type: org.openecomp.capabilities.metric.Ceilometer
243 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
248 type: tosca.capabilities.network.Bindable
250 - org.openecomp.resource.cp.nodes.heat.network.contrailV2.VLANSubInterface
255 type: tosca.capabilities.network.Bindable
257 - org.openecomp.resource.cp.nodes.heat.network.contrailV2.VLANSubInterface
261 memory.usage_server_pcm:
262 type: org.openecomp.capabilities.metric.Ceilometer
263 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
267 disk.read.requests_server_pcm:
268 type: org.openecomp.capabilities.metric.Ceilometer
269 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
273 disk.capacity_server_pcm:
274 type: org.openecomp.capabilities.metric.Ceilometer
275 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
280 type: tosca.capabilities.OperatingSystem
284 disk.read.bytes_server_pcm:
285 type: org.openecomp.capabilities.metric.Ceilometer
286 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
290 network.outgoing.packets.rate_pcm_port_0:
291 type: org.openecomp.capabilities.metric.Ceilometer
292 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
296 network.outgoing.packets.rate_pcm_port_1:
297 type: org.openecomp.capabilities.metric.Ceilometer
298 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
303 type: tosca.capabilities.Node
307 network.outgoing.bytes_pcm_port_0:
308 type: org.openecomp.capabilities.metric.Ceilometer
309 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
313 disk.device.read.bytes_server_pcm:
314 type: org.openecomp.capabilities.metric.Ceilometer
315 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
320 type: tosca.capabilities.Node
324 network.outgoing.bytes_pcm_port_1:
325 type: org.openecomp.capabilities.metric.Ceilometer
326 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
330 attachment_pcm_port_0:
331 type: tosca.capabilities.Attachment
335 attachment_pcm_port_1:
336 type: tosca.capabilities.Attachment
341 type: tosca.capabilities.Endpoint.Admin
345 disk.device.read.requests.rate_server_pcm:
346 type: org.openecomp.capabilities.metric.Ceilometer
347 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
352 type: org.openecomp.capabilities.metric.Ceilometer
353 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
357 disk.write.bytes_server_pcm:
358 type: org.openecomp.capabilities.metric.Ceilometer
359 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
363 disk.iops_server_pcm:
364 type: org.openecomp.capabilities.metric.Ceilometer
365 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
369 disk.read.bytes.rate_server_pcm:
370 type: org.openecomp.capabilities.metric.Ceilometer
371 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
375 disk.device.allocation_server_pcm:
376 type: org.openecomp.capabilities.metric.Ceilometer
377 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
382 type: tosca.capabilities.Scalable
386 disk.device.read.bytes.rate_server_pcm:
387 type: org.openecomp.capabilities.metric.Ceilometer
388 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
393 type: org.openecomp.capabilities.metric.Ceilometer
394 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
398 disk.write.requests.rate_server_pcm:
399 type: org.openecomp.capabilities.metric.Ceilometer
400 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
404 disk.device.write.bytes.rate_server_pcm:
405 type: org.openecomp.capabilities.metric.Ceilometer
406 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
411 type: tosca.capabilities.Container
413 - tosca.nodes.SoftwareComponent
417 cpu.delta_server_pcm:
418 type: org.openecomp.capabilities.metric.Ceilometer
419 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
423 network.outgoing.bytes.rate_pcm_port_1:
424 type: org.openecomp.capabilities.metric.Ceilometer
425 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
429 network.incoming.packets_pcm_port_0:
430 type: org.openecomp.capabilities.metric.Ceilometer
431 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
436 type: tosca.capabilities.network.Bindable
440 network.outgoing.bytes.rate_pcm_port_0:
441 type: org.openecomp.capabilities.metric.Ceilometer
442 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
446 disk.device.capacity_server_pcm:
447 type: org.openecomp.capabilities.metric.Ceilometer
448 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
452 network.incoming.packets_pcm_port_1:
453 type: org.openecomp.capabilities.metric.Ceilometer
454 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
459 type: org.openecomp.capabilities.metric.Ceilometer
460 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
464 disk.device.write.requests.rate_server_pcm:
465 type: org.openecomp.capabilities.metric.Ceilometer
466 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
470 disk.latency_server_pcm:
471 type: org.openecomp.capabilities.metric.Ceilometer
472 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
476 disk.device.read.requests_server_pcm:
477 type: org.openecomp.capabilities.metric.Ceilometer
478 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
483 type: tosca.capabilities.Node
487 network.incoming.bytes.rate_pcm_port_0:
488 type: org.openecomp.capabilities.metric.Ceilometer
489 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
493 disk.write.bytes.rate_server_pcm:
494 type: org.openecomp.capabilities.metric.Ceilometer
495 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
499 network.incoming.bytes.rate_pcm_port_1:
500 type: org.openecomp.capabilities.metric.Ceilometer
501 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
505 org.openecomp.resource.abstract.nodes.heat.oam_server:
506 derived_from: org.openecomp.resource.abstract.nodes.VFC
510 description: UID of OAM network
513 availabilityzone_name:
515 description: availabilityzone name
520 description: CPS network gateway
525 description: flavor name of PCRF CM instance
530 description: the name of security group
535 description: CPS network ip
540 description: oam server name
545 description: CPS Cluman Cinder Volume
550 description: oam image name
555 description: CPS network name
560 description: CPS network mask
565 description: OAM network ip
570 description: CPS network mask
573 shared_security_group_id1:
575 description: UID of OAM network
580 description: OAM network name
586 description: the oam nova service id
589 - dependency_oam_port_0:
590 capability: tosca.capabilities.Node
591 node: tosca.nodes.Root
592 relationship: tosca.relationships.DependsOn
597 capability: tosca.capabilities.network.Linkable
598 relationship: tosca.relationships.network.LinksTo
602 - dependency_server_oam:
603 capability: tosca.capabilities.Node
604 node: tosca.nodes.Root
605 relationship: tosca.relationships.DependsOn
609 - local_storage_server_oam:
610 capability: tosca.capabilities.Attachment
611 node: tosca.nodes.BlockStorage
612 relationship: tosca.relationships.AttachesTo
616 - dependency_oam_port_1:
617 capability: tosca.capabilities.Node
618 node: tosca.nodes.Root
619 relationship: tosca.relationships.DependsOn
624 capability: tosca.capabilities.network.Linkable
625 relationship: tosca.relationships.network.LinksTo
631 type: org.openecomp.capabilities.metric.Ceilometer
632 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
637 type: org.openecomp.capabilities.metric.Ceilometer
638 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
642 disk.write.requests_server_oam:
643 type: org.openecomp.capabilities.metric.Ceilometer
644 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
648 network.incoming.bytes.rate_oam_port_1:
649 type: org.openecomp.capabilities.metric.Ceilometer
650 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
654 network.incoming.bytes.rate_oam_port_0:
655 type: org.openecomp.capabilities.metric.Ceilometer
656 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
660 network.outgoing.bytes_oam_port_0:
661 type: org.openecomp.capabilities.metric.Ceilometer
662 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
666 memory.resident_server_oam:
667 type: org.openecomp.capabilities.metric.Ceilometer
668 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
672 network.outgoing.bytes_oam_port_1:
673 type: org.openecomp.capabilities.metric.Ceilometer
674 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
678 disk.device.iops_server_oam:
679 type: org.openecomp.capabilities.metric.Ceilometer
680 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
684 network.incoming.bytes_oam_port_0:
685 type: org.openecomp.capabilities.metric.Ceilometer
686 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
690 network.incoming.bytes_oam_port_1:
691 type: org.openecomp.capabilities.metric.Ceilometer
692 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
696 disk.device.write.requests_server_oam:
697 type: org.openecomp.capabilities.metric.Ceilometer
698 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
702 network.outgoing.bytes.rate_oam_port_0:
703 type: org.openecomp.capabilities.metric.Ceilometer
704 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
708 disk.allocation_server_oam:
709 type: org.openecomp.capabilities.metric.Ceilometer
710 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
714 network.outgoing.bytes.rate_oam_port_1:
715 type: org.openecomp.capabilities.metric.Ceilometer
716 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
720 disk.device.usage_server_oam:
721 type: org.openecomp.capabilities.metric.Ceilometer
722 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
726 network.outgoing.packets.rate_oam_port_0:
727 type: org.openecomp.capabilities.metric.Ceilometer
728 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
732 network.outgoing.packets.rate_oam_port_1:
733 type: org.openecomp.capabilities.metric.Ceilometer
734 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
738 disk.usage_server_oam:
739 type: org.openecomp.capabilities.metric.Ceilometer
740 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
744 disk.device.write.bytes_server_oam:
745 type: org.openecomp.capabilities.metric.Ceilometer
746 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
750 attachment_oam_port_1:
751 type: tosca.capabilities.Attachment
755 attachment_oam_port_0:
756 type: tosca.capabilities.Attachment
760 disk.ephemeral.size_server_oam:
761 type: org.openecomp.capabilities.metric.Ceilometer
762 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
766 disk.device.latency_server_oam:
767 type: org.openecomp.capabilities.metric.Ceilometer
768 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
772 disk.root.size_server_oam:
773 type: org.openecomp.capabilities.metric.Ceilometer
774 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
778 memory.usage_server_oam:
779 type: org.openecomp.capabilities.metric.Ceilometer
780 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
784 disk.read.bytes_server_oam:
785 type: org.openecomp.capabilities.metric.Ceilometer
786 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
791 type: tosca.capabilities.OperatingSystem
795 disk.read.requests_server_oam:
796 type: org.openecomp.capabilities.metric.Ceilometer
797 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
801 disk.capacity_server_oam:
802 type: org.openecomp.capabilities.metric.Ceilometer
803 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
808 type: tosca.capabilities.Node
812 disk.device.read.bytes_server_oam:
813 type: org.openecomp.capabilities.metric.Ceilometer
814 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
819 type: tosca.capabilities.Endpoint.Admin
823 disk.device.read.requests.rate_server_oam:
824 type: org.openecomp.capabilities.metric.Ceilometer
825 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
830 type: org.openecomp.capabilities.metric.Ceilometer
831 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
836 type: tosca.capabilities.Node
840 disk.read.bytes.rate_server_oam:
841 type: org.openecomp.capabilities.metric.Ceilometer
842 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
846 disk.write.bytes_server_oam:
847 type: org.openecomp.capabilities.metric.Ceilometer
848 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
852 disk.iops_server_oam:
853 type: org.openecomp.capabilities.metric.Ceilometer
854 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
858 network.incoming.packets.rate_oam_port_0:
859 type: org.openecomp.capabilities.metric.Ceilometer
860 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
864 disk.device.allocation_server_oam:
865 type: org.openecomp.capabilities.metric.Ceilometer
866 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
870 network.incoming.packets.rate_oam_port_1:
871 type: org.openecomp.capabilities.metric.Ceilometer
872 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
876 disk.write.requests.rate_server_oam:
877 type: org.openecomp.capabilities.metric.Ceilometer
878 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
882 network.outpoing.packets_oam_port_0:
883 type: org.openecomp.capabilities.metric.Ceilometer
884 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
889 type: tosca.capabilities.Scalable
893 disk.device.read.bytes.rate_server_oam:
894 type: org.openecomp.capabilities.metric.Ceilometer
895 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
900 type: tosca.capabilities.network.Bindable
902 - org.openecomp.resource.cp.nodes.heat.network.contrailV2.VLANSubInterface
906 network.incoming.packets_oam_port_1:
907 type: org.openecomp.capabilities.metric.Ceilometer
908 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
912 network.incoming.packets_oam_port_0:
913 type: org.openecomp.capabilities.metric.Ceilometer
914 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
919 type: org.openecomp.capabilities.metric.Ceilometer
920 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
925 type: tosca.capabilities.network.Bindable
927 - org.openecomp.resource.cp.nodes.heat.network.contrailV2.VLANSubInterface
931 network.outpoing.packets_oam_port_1:
932 type: org.openecomp.capabilities.metric.Ceilometer
933 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
937 cpu.delta_server_oam:
938 type: org.openecomp.capabilities.metric.Ceilometer
939 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
944 type: tosca.capabilities.Container
946 - tosca.nodes.SoftwareComponent
950 disk.device.write.bytes.rate_server_oam:
951 type: org.openecomp.capabilities.metric.Ceilometer
952 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
957 type: tosca.capabilities.network.Bindable
961 disk.device.capacity_server_oam:
962 type: org.openecomp.capabilities.metric.Ceilometer
963 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
967 disk.latency_server_oam:
968 type: org.openecomp.capabilities.metric.Ceilometer
969 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
974 type: org.openecomp.capabilities.metric.Ceilometer
975 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
979 disk.device.read.requests_server_oam:
980 type: org.openecomp.capabilities.metric.Ceilometer
981 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
985 disk.device.write.requests.rate_server_oam:
986 type: org.openecomp.capabilities.metric.Ceilometer
987 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
992 type: tosca.capabilities.Node
996 disk.write.bytes.rate_server_oam:
997 type: org.openecomp.capabilities.metric.Ceilometer
998 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1002 org.openecomp.resource.abstract.nodes.compute:
1003 derived_from: org.openecomp.resource.abstract.nodes.VFC
1005 compute_compute_user_data_format:
1017 description: Index value of this substitution service template runtime instance
1022 - greater_or_equal: 0
1023 compute_compute_metadata:
1029 compute_compute_name:
1039 compute_compute_config_drive:
1046 - dependency_compute:
1047 capability: tosca.capabilities.Node
1048 node: tosca.nodes.Root
1049 relationship: tosca.relationships.DependsOn
1053 - local_storage_compute:
1054 capability: tosca.capabilities.Attachment
1055 node: tosca.nodes.BlockStorage
1056 relationship: tosca.relationships.AttachesTo
1061 disk.device.usage_compute:
1062 type: org.openecomp.capabilities.metric.Ceilometer
1063 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1067 disk.write.requests_compute:
1068 type: org.openecomp.capabilities.metric.Ceilometer
1069 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1074 type: org.openecomp.capabilities.metric.Ceilometer
1075 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1079 disk.ephemeral.size_compute:
1080 type: org.openecomp.capabilities.metric.Ceilometer
1081 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1085 disk.device.read.bytes.rate_compute:
1086 type: org.openecomp.capabilities.metric.Ceilometer
1087 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1091 disk.latency_compute:
1092 type: org.openecomp.capabilities.metric.Ceilometer
1093 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1097 memory.resident_compute:
1098 type: org.openecomp.capabilities.metric.Ceilometer
1099 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1104 type: org.openecomp.capabilities.metric.Ceilometer
1105 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1110 type: org.openecomp.capabilities.metric.Ceilometer
1111 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1115 disk.root.size_compute:
1116 type: org.openecomp.capabilities.metric.Ceilometer
1117 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1121 disk.write.requests.rate_compute:
1122 type: org.openecomp.capabilities.metric.Ceilometer
1123 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1127 disk.read.requests_compute:
1128 type: org.openecomp.capabilities.metric.Ceilometer
1129 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1133 disk.device.read.requests.rate_compute:
1134 type: org.openecomp.capabilities.metric.Ceilometer
1135 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1139 disk.read.bytes_compute:
1140 type: org.openecomp.capabilities.metric.Ceilometer
1141 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1145 disk.device.read.bytes_compute:
1146 type: org.openecomp.capabilities.metric.Ceilometer
1147 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1151 disk.write.bytes_compute:
1152 type: org.openecomp.capabilities.metric.Ceilometer
1153 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1158 type: org.openecomp.capabilities.metric.Ceilometer
1159 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1164 type: tosca.capabilities.OperatingSystem
1168 disk.write.bytes.rate_compute:
1169 type: org.openecomp.capabilities.metric.Ceilometer
1170 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1175 type: org.openecomp.capabilities.metric.Ceilometer
1176 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1180 disk.capacity_compute:
1181 type: org.openecomp.capabilities.metric.Ceilometer
1182 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1187 type: org.openecomp.capabilities.metric.Ceilometer
1188 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1192 disk.read.bytes.rate_compute:
1193 type: org.openecomp.capabilities.metric.Ceilometer
1194 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1198 disk.device.latency_compute:
1199 type: org.openecomp.capabilities.metric.Ceilometer
1200 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1204 disk.device.write.requests_compute:
1205 type: org.openecomp.capabilities.metric.Ceilometer
1206 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1210 disk.device.iops_compute:
1211 type: org.openecomp.capabilities.metric.Ceilometer
1212 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1216 disk.device.write.requests.rate_compute:
1217 type: org.openecomp.capabilities.metric.Ceilometer
1218 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1223 type: tosca.capabilities.Endpoint.Admin
1227 memory.usage_compute:
1228 type: org.openecomp.capabilities.metric.Ceilometer
1229 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1234 type: tosca.capabilities.Container
1236 - tosca.nodes.SoftwareComponent
1241 type: tosca.capabilities.Node
1245 disk.device.write.bytes_compute:
1246 type: org.openecomp.capabilities.metric.Ceilometer
1247 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1252 type: org.openecomp.capabilities.metric.Ceilometer
1253 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1257 disk.device.write.bytes.rate_compute:
1258 type: org.openecomp.capabilities.metric.Ceilometer
1259 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1264 type: tosca.capabilities.Scalable
1268 disk.device.read.requests_compute:
1269 type: org.openecomp.capabilities.metric.Ceilometer
1270 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1274 disk.allocation_compute:
1275 type: org.openecomp.capabilities.metric.Ceilometer
1276 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1280 disk.device.capacity_compute:
1281 type: org.openecomp.capabilities.metric.Ceilometer
1282 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1286 disk.device.allocation_compute:
1287 type: org.openecomp.capabilities.metric.Ceilometer
1288 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1293 type: org.openecomp.capabilities.metric.Ceilometer
1294 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1299 type: tosca.capabilities.network.Bindable