1 tosca_definitions_version: tosca_simple_yaml_1_0_0
3 template_name: Nested_pd_server_1b
5 - openecomp_heat_index:
6 file: openecomp-heat/_index.yml
7 - GlobalSubstitutionTypes:
8 file: GlobalSubstitutionTypesServiceTemplate.yaml
10 org.openecomp.resource.vfc.compute.nodes.heat.pd_server_1b:
11 derived_from: org.openecomp.resource.vfc.nodes.heat.nova.Server
14 port_ps_server_1b_port_vlan_requirements:
18 type: org.openecomp.datatypes.network.VlanRequirements
19 compute_pd_server_1b_name:
24 port_ps_server_1b_port_mac_requirements:
25 type: org.openecomp.datatypes.network.MacRequirements
27 port_ps_server_1b_port_network_role_tag:
30 port_ps_server_1b_port_fixed_ips:
34 type: org.openecomp.datatypes.heat.neutron.port.FixedIps
37 description: Index value of this substitution service template runtime instance
42 port_ps_server_1b_port_order:
48 port_ps_server_1b_port_related_networks:
52 type: org.openecomp.datatypes.network.RelatedNetworksAssignments
53 port_ps_server_1b_port_network:
58 port_ps_server_1b_port_exCP_naming:
59 type: org.openecomp.datatypes.Naming
61 port_ps_server_1b_port_ip_requirements:
65 type: org.openecomp.datatypes.network.IpRequirements
69 port_ps_server_1b_port_network_role:
72 port_ps_server_1b_port_replacement_policy:
77 port_ps_server_1b_port_subnetpoolid:
80 compute_pd_server_1b_availability_zone:
87 type: org.openecomp.resource.vfc.compute.nodes.heat.pd_server_1b
91 - compute_pd_server_1b_availability_zone
94 get_input: vm_flavor_name
96 get_input: vm_image_name
99 - compute_pd_server_1b_name
101 pd_server_1b_ps_server_1b_port:
102 type: org.openecomp.resource.cp.nodes.heat.network.neutron.Port
106 - port_ps_server_1b_port_replacement_policy
109 get_input: port_ps_server_1b_port_mac_requirements
111 get_input: port_ps_server_1b_port_order
113 get_input: port_ps_server_1b_port_exCP_naming
115 get_input: port_ps_server_1b_port_vlan_requirements
116 subinterface_indicator: false
118 get_input: port_ps_server_1b_port_ip_requirements
120 get_input: port_ps_server_1b_port_related_networks
122 get_input: port_ps_server_1b_port_network_role_tag
124 get_input: port_ps_server_1b_port_network_role
127 - port_ps_server_1b_port_fixed_ips
130 get_input: port_ps_server_1b_port_subnetpoolid
133 - port_ps_server_1b_port_network
137 capability: tosca.capabilities.network.Bindable
139 relationship: tosca.relationships.network.BindsTo
140 substitution_mappings:
141 node_type: org.openecomp.resource.abstract.nodes.pd_server_1b
143 disk.device.read.bytes_pd_server_1b:
145 - disk.device.read.bytes
149 network.outpoing.packets_pd_server_1b_ps_server_1b_port:
150 - pd_server_1b_ps_server_1b_port
151 - network.outpoing.packets
152 disk.read.bytes.rate_pd_server_1b:
154 - disk.read.bytes.rate
155 disk.allocation_pd_server_1b:
158 network.incoming.bytes.rate_pd_server_1b_ps_server_1b_port:
159 - pd_server_1b_ps_server_1b_port
160 - network.incoming.bytes.rate
161 feature_pd_server_1b_ps_server_1b_port:
162 - pd_server_1b_ps_server_1b_port
164 cpu.delta_pd_server_1b:
167 network.incoming.packets_pd_server_1b_ps_server_1b_port:
168 - pd_server_1b_ps_server_1b_port
169 - network.incoming.packets
170 forwarder_pd_server_1b_ps_server_1b_port:
171 - pd_server_1b_ps_server_1b_port
173 disk.device.read.requests_pd_server_1b:
175 - disk.device.read.requests
176 feature_pd_server_1b:
179 disk.device.iops_pd_server_1b:
182 network.outgoing.bytes.rate_pd_server_1b_ps_server_1b_port:
183 - pd_server_1b_ps_server_1b_port
184 - network.outgoing.bytes.rate
188 disk.write.bytes.rate_pd_server_1b:
190 - disk.write.bytes.rate
191 disk.device.read.requests.rate_pd_server_1b:
193 - disk.device.read.requests.rate
194 endpoint_pd_server_1b:
197 disk.device.allocation_pd_server_1b:
199 - disk.device.allocation
200 memory.usage_pd_server_1b:
206 network.outgoing.bytes_pd_server_1b_ps_server_1b_port:
207 - pd_server_1b_ps_server_1b_port
208 - network.outgoing.bytes
209 disk.device.read.bytes.rate_pd_server_1b:
211 - disk.device.read.bytes.rate
212 disk.device.latency_pd_server_1b:
214 - disk.device.latency
215 disk.read.bytes_pd_server_1b:
218 disk.device.usage_pd_server_1b:
221 disk.device.write.requests_pd_server_1b:
223 - disk.device.write.requests
224 disk.latency_pd_server_1b:
227 disk.ephemeral.size_pd_server_1b:
229 - disk.ephemeral.size
230 binding_pd_server_1b_ps_server_1b_port:
231 - pd_server_1b_ps_server_1b_port
233 scalable_pd_server_1b:
236 disk.write.requests_pd_server_1b:
238 - disk.write.requests
239 disk.device.write.bytes.rate_pd_server_1b:
241 - disk.device.write.bytes.rate
242 disk.root.size_pd_server_1b:
245 disk.iops_pd_server_1b:
248 disk.write.bytes_pd_server_1b:
251 disk.device.write.bytes_pd_server_1b:
253 - disk.device.write.bytes
260 instance_pd_server_1b:
263 network.outgoing.packets.rate_pd_server_1b_ps_server_1b_port:
264 - pd_server_1b_ps_server_1b_port
265 - network.outgoing.packets.rate
266 binding_pd_server_1b:
269 cpu_util_pd_server_1b:
272 memory.resident_pd_server_1b:
275 network.incoming.packets.rate_pd_server_1b_ps_server_1b_port:
276 - pd_server_1b_ps_server_1b_port
277 - network.incoming.packets.rate
278 attachment_pd_server_1b_ps_server_1b_port:
279 - pd_server_1b_ps_server_1b_port
281 network.incoming.bytes_pd_server_1b_ps_server_1b_port:
282 - pd_server_1b_ps_server_1b_port
283 - network.incoming.bytes
284 disk.device.write.requests.rate_pd_server_1b:
286 - disk.device.write.requests.rate
287 disk.device.capacity_pd_server_1b:
289 - disk.device.capacity
290 disk.read.requests_pd_server_1b:
293 disk.capacity_pd_server_1b:
296 disk.usage_pd_server_1b:
299 disk.write.requests.rate_pd_server_1b:
301 - disk.write.requests.rate
303 dependency_pd_server_1b:
306 local_storage_pd_server_1b:
309 dependency_pd_server_1b_ps_server_1b_port:
310 - pd_server_1b_ps_server_1b_port
312 link_pd_server_1b_ps_server_1b_port:
313 - pd_server_1b_ps_server_1b_port