1 tosca_definitions_version: tosca_simple_yaml_1_0_0
3 template_name: GlobalSubstitutionTypes
5 - openecomp_heat_index:
6 file: openecomp-heat/_index.yml
8 org.openecomp.resource.abstract.nodes.heat.nested:
9 derived_from: org.openecomp.resource.abstract.nodes.AbstractSubstitute
13 description: CMAUI1, CMAUI2 server names
20 description: UID of OAM network
25 description: Image for CMAUI server
30 description: Flavor for CMAUI server
35 description: availabilityzone name
40 description: cmaui_port_1
45 description: UID of OAM network
48 shared_security_group_id1:
50 description: UID of OAM network
58 - dependency_cmaui_port_2:
59 capability: tosca.capabilities.Node
60 node: tosca.nodes.Root
61 relationship: tosca.relationships.DependsOn
66 capability: tosca.capabilities.network.Linkable
67 relationship: tosca.relationships.network.LinksTo
71 - dependency_test_nested2:
72 capability: tosca.capabilities.Node
73 node: tosca.nodes.Root
74 relationship: tosca.relationships.DependsOn
78 - dependency_cmaui_port_11_test_nested2:
79 capability: tosca.capabilities.Node
80 node: tosca.nodes.Root
81 relationship: tosca.relationships.DependsOn
85 - link_cmaui_port_11_test_nested2:
86 capability: tosca.capabilities.network.Linkable
87 relationship: tosca.relationships.network.LinksTo
91 - dependency_cmaui_port_22_test_nested2:
92 capability: tosca.capabilities.Node
93 node: tosca.nodes.Root
94 relationship: tosca.relationships.DependsOn
98 - link_cmaui_port_22_test_nested2:
99 capability: tosca.capabilities.network.Linkable
100 relationship: tosca.relationships.network.LinksTo
104 - dependency_server_cmaui_test_nested2:
105 capability: tosca.capabilities.Node
106 node: tosca.nodes.Root
107 relationship: tosca.relationships.DependsOn
111 - local_storage_server_cmaui_test_nested2:
112 capability: tosca.capabilities.Attachment
113 node: tosca.nodes.BlockStorage
114 relationship: tosca.relationships.AttachesTo
118 - dependency_server_cmaui:
119 capability: tosca.capabilities.Node
120 node: tosca.nodes.Root
121 relationship: tosca.relationships.DependsOn
125 - local_storage_server_cmaui:
126 capability: tosca.capabilities.Attachment
127 node: tosca.nodes.BlockStorage
128 relationship: tosca.relationships.AttachesTo
132 - dependency_cmaui_port_1:
133 capability: tosca.capabilities.Node
134 node: tosca.nodes.Root
135 relationship: tosca.relationships.DependsOn
140 capability: tosca.capabilities.network.Linkable
141 relationship: tosca.relationships.network.LinksTo
146 cpu.delta_server_cmaui:
147 type: org.openecomp.capabilities.metric.Ceilometer
148 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
152 disk.device.write.requests.rate_server_cmaui:
153 type: org.openecomp.capabilities.metric.Ceilometer
154 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
158 network.incoming.packets.rate_cmaui_port_22_test_nested2:
159 type: org.openecomp.capabilities.metric.Ceilometer
160 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
164 disk.device.allocation_server_cmaui:
165 type: org.openecomp.capabilities.metric.Ceilometer
166 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
170 disk.write.requests.rate_server_cmaui_test_nested2:
171 type: org.openecomp.capabilities.metric.Ceilometer
172 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
176 disk.capacity_server_cmaui_test_nested2:
177 type: org.openecomp.capabilities.metric.Ceilometer
178 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
182 scalable_server_cmaui:
183 type: tosca.capabilities.Scalable
187 disk.read.bytes.rate_server_cmaui:
188 type: org.openecomp.capabilities.metric.Ceilometer
189 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
193 disk.latency_server_cmaui_test_nested2:
194 type: org.openecomp.capabilities.metric.Ceilometer
195 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
199 disk.read.bytes.rate_server_cmaui_test_nested2:
200 type: org.openecomp.capabilities.metric.Ceilometer
201 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
206 type: tosca.capabilities.Container
208 - tosca.nodes.SoftwareComponent
212 cpu_util_server_cmaui:
213 type: org.openecomp.capabilities.metric.Ceilometer
214 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
218 binding_cmaui_port_11_test_nested2:
219 type: tosca.capabilities.network.Bindable
221 - org.openecomp.resource.cp.nodes.heat.network.contrailV2.VLANSubInterface
225 endpoint_server_cmaui_test_nested2:
226 type: tosca.capabilities.Endpoint.Admin
230 disk.device.read.bytes_server_cmaui_test_nested2:
231 type: org.openecomp.capabilities.metric.Ceilometer
232 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
236 disk.device.write.requests_server_cmaui:
237 type: org.openecomp.capabilities.metric.Ceilometer
238 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
242 network.outgoing.bytes_cmaui_port_2:
243 type: org.openecomp.capabilities.metric.Ceilometer
244 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
248 network.outgoing.bytes_cmaui_port_1:
249 type: org.openecomp.capabilities.metric.Ceilometer
250 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
254 memory.usage_server_cmaui_test_nested2:
255 type: org.openecomp.capabilities.metric.Ceilometer
256 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
260 network.incoming.packets.rate_cmaui_port_11_test_nested2:
261 type: org.openecomp.capabilities.metric.Ceilometer
262 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
266 instance_server_cmaui:
267 type: org.openecomp.capabilities.metric.Ceilometer
268 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
272 disk.device.read.bytes_server_cmaui:
273 type: org.openecomp.capabilities.metric.Ceilometer
274 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
278 disk.root.size_server_cmaui:
279 type: org.openecomp.capabilities.metric.Ceilometer
280 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
284 binding_cmaui_port_22_test_nested2:
285 type: tosca.capabilities.network.Bindable
287 - org.openecomp.resource.cp.nodes.heat.network.contrailV2.VLANSubInterface
291 binding_server_cmaui_test_nested2:
292 type: tosca.capabilities.network.Bindable
296 network.incoming.packets_cmaui_port_2:
297 type: org.openecomp.capabilities.metric.Ceilometer
298 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
303 type: tosca.capabilities.OperatingSystem
307 disk.device.write.bytes.rate_server_cmaui:
308 type: org.openecomp.capabilities.metric.Ceilometer
309 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
313 disk.allocation_server_cmaui_test_nested2:
314 type: org.openecomp.capabilities.metric.Ceilometer
315 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
319 network.incoming.packets_cmaui_port_1:
320 type: org.openecomp.capabilities.metric.Ceilometer
321 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
325 disk.read.requests_server_cmaui_test_nested2:
326 type: org.openecomp.capabilities.metric.Ceilometer
327 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
331 network.incoming.bytes.rate_cmaui_port_22_test_nested2:
332 type: org.openecomp.capabilities.metric.Ceilometer
333 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
337 disk.write.requests_server_cmaui_test_nested2:
338 type: org.openecomp.capabilities.metric.Ceilometer
339 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
343 network.outpoing.packets_cmaui_port_11_test_nested2:
344 type: org.openecomp.capabilities.metric.Ceilometer
345 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
349 os_server_cmaui_test_nested2:
350 type: tosca.capabilities.OperatingSystem
354 feature_cmaui_port_22_test_nested2:
355 type: tosca.capabilities.Node
359 cpu_util_server_cmaui_test_nested2:
360 type: org.openecomp.capabilities.metric.Ceilometer
361 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
365 feature_server_cmaui:
366 type: tosca.capabilities.Node
370 binding_cmaui_port_1:
371 type: tosca.capabilities.network.Bindable
373 - org.openecomp.resource.cp.nodes.heat.network.contrailV2.VLANSubInterface
377 binding_cmaui_port_2:
378 type: tosca.capabilities.network.Bindable
380 - org.openecomp.resource.cp.nodes.heat.network.contrailV2.VLANSubInterface
384 disk.write.bytes_server_cmaui_test_nested2:
385 type: org.openecomp.capabilities.metric.Ceilometer
386 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
390 vcpus_server_cmaui_test_nested2:
391 type: org.openecomp.capabilities.metric.Ceilometer
392 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
396 memory.usage_server_cmaui:
397 type: org.openecomp.capabilities.metric.Ceilometer
398 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
402 disk.ephemeral.size_server_cmaui:
403 type: org.openecomp.capabilities.metric.Ceilometer
404 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
408 network.outgoing.bytes.rate_cmaui_port_2:
409 type: org.openecomp.capabilities.metric.Ceilometer
410 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
414 cpu_server_cmaui_test_nested2:
415 type: org.openecomp.capabilities.metric.Ceilometer
416 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
420 memory.resident_server_cmaui_test_nested2:
421 type: org.openecomp.capabilities.metric.Ceilometer
422 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
426 network.outgoing.packets.rate_cmaui_port_22_test_nested2:
427 type: org.openecomp.capabilities.metric.Ceilometer
428 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
432 network.outgoing.bytes.rate_cmaui_port_1:
433 type: org.openecomp.capabilities.metric.Ceilometer
434 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
438 network.outgoing.bytes.rate_cmaui_port_11_test_nested2:
439 type: org.openecomp.capabilities.metric.Ceilometer
440 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
444 disk.iops_server_cmaui:
445 type: org.openecomp.capabilities.metric.Ceilometer
446 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
450 host_server_cmaui_test_nested2:
451 type: tosca.capabilities.Container
453 - tosca.nodes.SoftwareComponent
457 disk.usage_server_cmaui_test_nested2:
458 type: org.openecomp.capabilities.metric.Ceilometer
459 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
463 disk.device.iops_server_cmaui:
464 type: org.openecomp.capabilities.metric.Ceilometer
465 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
469 network.incoming.bytes_cmaui_port_2:
470 type: org.openecomp.capabilities.metric.Ceilometer
471 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
475 disk.read.bytes_server_cmaui:
476 type: org.openecomp.capabilities.metric.Ceilometer
477 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
481 network.incoming.bytes_cmaui_port_1:
482 type: org.openecomp.capabilities.metric.Ceilometer
483 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
487 disk.ephemeral.size_server_cmaui_test_nested2:
488 type: org.openecomp.capabilities.metric.Ceilometer
489 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
493 network.incoming.packets_cmaui_port_11_test_nested2:
494 type: org.openecomp.capabilities.metric.Ceilometer
495 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
499 network.incoming.bytes_cmaui_port_11_test_nested2:
500 type: org.openecomp.capabilities.metric.Ceilometer
501 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
505 disk.device.read.requests.rate_server_cmaui_test_nested2:
506 type: org.openecomp.capabilities.metric.Ceilometer
507 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
511 network.incoming.packets.rate_cmaui_port_1:
512 type: org.openecomp.capabilities.metric.Ceilometer
513 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
517 network.incoming.packets.rate_cmaui_port_2:
518 type: org.openecomp.capabilities.metric.Ceilometer
519 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
524 type: org.openecomp.capabilities.metric.Ceilometer
525 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
529 feature_cmaui_port_1:
530 type: tosca.capabilities.Node
534 feature_cmaui_port_2:
535 type: tosca.capabilities.Node
539 disk.write.bytes.rate_server_cmaui:
540 type: org.openecomp.capabilities.metric.Ceilometer
541 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
545 disk.device.read.bytes.rate_server_cmaui:
546 type: org.openecomp.capabilities.metric.Ceilometer
547 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
551 disk.device.write.bytes_server_cmaui_test_nested2:
552 type: org.openecomp.capabilities.metric.Ceilometer
553 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
557 network.incoming.bytes.rate_cmaui_port_11_test_nested2:
558 type: org.openecomp.capabilities.metric.Ceilometer
559 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
563 attachment_cmaui_port_2:
564 type: tosca.capabilities.Attachment
568 scalable_server_cmaui_test_nested2:
569 type: tosca.capabilities.Scalable
573 feature_test_nested2:
574 type: tosca.capabilities.Node
578 disk.device.latency_server_cmaui:
579 type: org.openecomp.capabilities.metric.Ceilometer
580 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
584 disk.read.requests_server_cmaui:
585 type: org.openecomp.capabilities.metric.Ceilometer
586 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
590 attachment_cmaui_port_22_test_nested2:
591 type: tosca.capabilities.Attachment
595 disk.device.capacity_server_cmaui:
596 type: org.openecomp.capabilities.metric.Ceilometer
597 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
601 network.outgoing.packets.rate_cmaui_port_1:
602 type: org.openecomp.capabilities.metric.Ceilometer
603 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
607 network.outgoing.packets.rate_cmaui_port_2:
608 type: org.openecomp.capabilities.metric.Ceilometer
609 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
613 disk.device.allocation_server_cmaui_test_nested2:
614 type: org.openecomp.capabilities.metric.Ceilometer
615 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
619 disk.read.bytes_server_cmaui_test_nested2:
620 type: org.openecomp.capabilities.metric.Ceilometer
621 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
625 disk.usage_server_cmaui:
626 type: org.openecomp.capabilities.metric.Ceilometer
627 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
631 disk.device.usage_server_cmaui:
632 type: org.openecomp.capabilities.metric.Ceilometer
633 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
637 attachment_cmaui_port_1:
638 type: tosca.capabilities.Attachment
642 memory_server_cmaui_test_nested2:
643 type: org.openecomp.capabilities.metric.Ceilometer
644 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
648 disk.capacity_server_cmaui:
649 type: org.openecomp.capabilities.metric.Ceilometer
650 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
654 disk.write.requests.rate_server_cmaui:
655 type: org.openecomp.capabilities.metric.Ceilometer
656 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
660 disk.device.read.requests_server_cmaui_test_nested2:
661 type: org.openecomp.capabilities.metric.Ceilometer
662 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
666 disk.device.read.bytes.rate_server_cmaui_test_nested2:
667 type: org.openecomp.capabilities.metric.Ceilometer
668 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
672 disk.device.read.requests_server_cmaui:
673 type: org.openecomp.capabilities.metric.Ceilometer
674 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
678 disk.device.latency_server_cmaui_test_nested2:
679 type: org.openecomp.capabilities.metric.Ceilometer
680 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
684 network.outgoing.bytes_cmaui_port_11_test_nested2:
685 type: org.openecomp.capabilities.metric.Ceilometer
686 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
690 disk.device.write.bytes.rate_server_cmaui_test_nested2:
691 type: org.openecomp.capabilities.metric.Ceilometer
692 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
696 instance_server_cmaui_test_nested2:
697 type: org.openecomp.capabilities.metric.Ceilometer
698 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
703 type: org.openecomp.capabilities.metric.Ceilometer
704 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
708 disk.write.bytes.rate_server_cmaui_test_nested2:
709 type: org.openecomp.capabilities.metric.Ceilometer
710 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
714 disk.device.usage_server_cmaui_test_nested2:
715 type: org.openecomp.capabilities.metric.Ceilometer
716 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
720 binding_server_cmaui:
721 type: tosca.capabilities.network.Bindable
725 disk.iops_server_cmaui_test_nested2:
726 type: org.openecomp.capabilities.metric.Ceilometer
727 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
731 disk.device.read.requests.rate_server_cmaui:
732 type: org.openecomp.capabilities.metric.Ceilometer
733 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
737 feature_server_cmaui_test_nested2:
738 type: tosca.capabilities.Node
742 disk.write.bytes_server_cmaui:
743 type: org.openecomp.capabilities.metric.Ceilometer
744 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
748 disk.device.iops_server_cmaui_test_nested2:
749 type: org.openecomp.capabilities.metric.Ceilometer
750 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
754 disk.device.write.requests.rate_server_cmaui_test_nested2:
755 type: org.openecomp.capabilities.metric.Ceilometer
756 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
760 network.outgoing.packets.rate_cmaui_port_11_test_nested2:
761 type: org.openecomp.capabilities.metric.Ceilometer
762 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
766 disk.device.write.requests_server_cmaui_test_nested2:
767 type: org.openecomp.capabilities.metric.Ceilometer
768 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
772 network.outgoing.bytes_cmaui_port_22_test_nested2:
773 type: org.openecomp.capabilities.metric.Ceilometer
774 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
778 memory.resident_server_cmaui:
779 type: org.openecomp.capabilities.metric.Ceilometer
780 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
784 disk.latency_server_cmaui:
785 type: org.openecomp.capabilities.metric.Ceilometer
786 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
791 type: org.openecomp.capabilities.metric.Ceilometer
792 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
796 network.outgoing.bytes.rate_cmaui_port_22_test_nested2:
797 type: org.openecomp.capabilities.metric.Ceilometer
798 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
802 disk.device.write.bytes_server_cmaui:
803 type: org.openecomp.capabilities.metric.Ceilometer
804 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
808 network.incoming.bytes.rate_cmaui_port_1:
809 type: org.openecomp.capabilities.metric.Ceilometer
810 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
814 network.incoming.bytes.rate_cmaui_port_2:
815 type: org.openecomp.capabilities.metric.Ceilometer
816 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
820 disk.root.size_server_cmaui_test_nested2:
821 type: org.openecomp.capabilities.metric.Ceilometer
822 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
826 disk.allocation_server_cmaui:
827 type: org.openecomp.capabilities.metric.Ceilometer
828 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
832 disk.write.requests_server_cmaui:
833 type: org.openecomp.capabilities.metric.Ceilometer
834 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
838 network.outpoing.packets_cmaui_port_1:
839 type: org.openecomp.capabilities.metric.Ceilometer
840 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
844 network.outpoing.packets_cmaui_port_2:
845 type: org.openecomp.capabilities.metric.Ceilometer
846 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
850 network.incoming.packets_cmaui_port_22_test_nested2:
851 type: org.openecomp.capabilities.metric.Ceilometer
852 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
856 network.incoming.bytes_cmaui_port_22_test_nested2:
857 type: org.openecomp.capabilities.metric.Ceilometer
858 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
862 cpu.delta_server_cmaui_test_nested2:
863 type: org.openecomp.capabilities.metric.Ceilometer
864 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
868 network.outpoing.packets_cmaui_port_22_test_nested2:
869 type: org.openecomp.capabilities.metric.Ceilometer
870 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
874 endpoint_server_cmaui:
875 type: tosca.capabilities.Endpoint.Admin
879 feature_cmaui_port_11_test_nested2:
880 type: tosca.capabilities.Node
884 attachment_cmaui_port_11_test_nested2:
885 type: tosca.capabilities.Attachment
889 disk.device.capacity_server_cmaui_test_nested2:
890 type: org.openecomp.capabilities.metric.Ceilometer
891 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
895 org.openecomp.resource.abstract.nodes.heat.nested2level:
896 derived_from: org.openecomp.resource.abstract.nodes.AbstractSubstitute
900 description: CMAUI1, CMAUI2 server names
907 description: UID of OAM network
912 description: Image for CMAUI server
917 description: Flavor for CMAUI server
922 description: availabilityzone name
927 description: cmaui_port_1
932 description: UID of OAM network
935 shared_security_group_id1:
937 description: UID of OAM network
941 - dependency_cmaui_port_11:
942 capability: tosca.capabilities.Node
943 node: tosca.nodes.Root
944 relationship: tosca.relationships.DependsOn
948 - link_cmaui_port_11:
949 capability: tosca.capabilities.network.Linkable
950 relationship: tosca.relationships.network.LinksTo
954 - dependency_cmaui_port_22:
955 capability: tosca.capabilities.Node
956 node: tosca.nodes.Root
957 relationship: tosca.relationships.DependsOn
961 - link_cmaui_port_22:
962 capability: tosca.capabilities.network.Linkable
963 relationship: tosca.relationships.network.LinksTo
967 - dependency_server_cmaui:
968 capability: tosca.capabilities.Node
969 node: tosca.nodes.Root
970 relationship: tosca.relationships.DependsOn
974 - local_storage_server_cmaui:
975 capability: tosca.capabilities.Attachment
976 node: tosca.nodes.BlockStorage
977 relationship: tosca.relationships.AttachesTo
982 cpu.delta_server_cmaui:
983 type: org.openecomp.capabilities.metric.Ceilometer
984 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
988 disk.device.write.requests.rate_server_cmaui:
989 type: org.openecomp.capabilities.metric.Ceilometer
990 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
994 disk.device.allocation_server_cmaui:
995 type: org.openecomp.capabilities.metric.Ceilometer
996 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1000 network.outpoing.packets_cmaui_port_11:
1001 type: org.openecomp.capabilities.metric.Ceilometer
1002 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1006 network.outgoing.packets.rate_cmaui_port_22:
1007 type: org.openecomp.capabilities.metric.Ceilometer
1008 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1012 binding_cmaui_port_22:
1013 type: tosca.capabilities.network.Bindable
1015 - org.openecomp.resource.cp.nodes.heat.network.contrailV2.VLANSubInterface
1019 scalable_server_cmaui:
1020 type: tosca.capabilities.Scalable
1024 disk.read.bytes.rate_server_cmaui:
1025 type: org.openecomp.capabilities.metric.Ceilometer
1026 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1031 type: org.openecomp.capabilities.metric.Ceilometer
1032 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1036 disk.write.bytes.rate_server_cmaui:
1037 type: org.openecomp.capabilities.metric.Ceilometer
1038 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1042 disk.device.read.bytes.rate_server_cmaui:
1043 type: org.openecomp.capabilities.metric.Ceilometer
1044 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1049 type: tosca.capabilities.Container
1051 - tosca.nodes.SoftwareComponent
1055 cpu_util_server_cmaui:
1056 type: org.openecomp.capabilities.metric.Ceilometer
1057 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1061 network.incoming.packets.rate_cmaui_port_22:
1062 type: org.openecomp.capabilities.metric.Ceilometer
1063 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1067 disk.device.latency_server_cmaui:
1068 type: org.openecomp.capabilities.metric.Ceilometer
1069 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1073 disk.device.write.requests_server_cmaui:
1074 type: org.openecomp.capabilities.metric.Ceilometer
1075 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1079 disk.read.requests_server_cmaui:
1080 type: org.openecomp.capabilities.metric.Ceilometer
1081 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1085 disk.device.capacity_server_cmaui:
1086 type: org.openecomp.capabilities.metric.Ceilometer
1087 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1091 disk.usage_server_cmaui:
1092 type: org.openecomp.capabilities.metric.Ceilometer
1093 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1097 disk.device.usage_server_cmaui:
1098 type: org.openecomp.capabilities.metric.Ceilometer
1099 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1103 network.outgoing.bytes.rate_cmaui_port_22:
1104 type: org.openecomp.capabilities.metric.Ceilometer
1105 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1109 disk.capacity_server_cmaui:
1110 type: org.openecomp.capabilities.metric.Ceilometer
1111 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1115 disk.write.requests.rate_server_cmaui:
1116 type: org.openecomp.capabilities.metric.Ceilometer
1117 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1121 network.outpoing.packets_cmaui_port_22:
1122 type: org.openecomp.capabilities.metric.Ceilometer
1123 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1127 disk.device.read.requests_server_cmaui:
1128 type: org.openecomp.capabilities.metric.Ceilometer
1129 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1133 instance_server_cmaui:
1134 type: org.openecomp.capabilities.metric.Ceilometer
1135 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1139 disk.device.read.bytes_server_cmaui:
1140 type: org.openecomp.capabilities.metric.Ceilometer
1141 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1145 memory_server_cmaui:
1146 type: org.openecomp.capabilities.metric.Ceilometer
1147 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1151 feature_cmaui_port_22:
1152 type: tosca.capabilities.Node
1156 disk.root.size_server_cmaui:
1157 type: org.openecomp.capabilities.metric.Ceilometer
1158 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1162 network.incoming.bytes.rate_cmaui_port_22:
1163 type: org.openecomp.capabilities.metric.Ceilometer
1164 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1168 binding_server_cmaui:
1169 type: tosca.capabilities.network.Bindable
1173 disk.device.read.requests.rate_server_cmaui:
1174 type: org.openecomp.capabilities.metric.Ceilometer
1175 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1179 disk.write.bytes_server_cmaui:
1180 type: org.openecomp.capabilities.metric.Ceilometer
1181 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1186 type: tosca.capabilities.OperatingSystem
1190 disk.device.write.bytes.rate_server_cmaui:
1191 type: org.openecomp.capabilities.metric.Ceilometer
1192 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1196 network.outgoing.bytes.rate_cmaui_port_11:
1197 type: org.openecomp.capabilities.metric.Ceilometer
1198 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1202 feature_cmaui_port_11:
1203 type: tosca.capabilities.Node
1207 attachment_cmaui_port_22:
1208 type: tosca.capabilities.Attachment
1212 network.incoming.bytes.rate_cmaui_port_11:
1213 type: org.openecomp.capabilities.metric.Ceilometer
1214 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1218 network.outgoing.bytes_cmaui_port_11:
1219 type: org.openecomp.capabilities.metric.Ceilometer
1220 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1224 network.incoming.packets_cmaui_port_22:
1225 type: org.openecomp.capabilities.metric.Ceilometer
1226 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1230 memory.resident_server_cmaui:
1231 type: org.openecomp.capabilities.metric.Ceilometer
1232 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1236 network.incoming.bytes_cmaui_port_22:
1237 type: org.openecomp.capabilities.metric.Ceilometer
1238 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1242 disk.latency_server_cmaui:
1243 type: org.openecomp.capabilities.metric.Ceilometer
1244 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1248 feature_server_cmaui:
1249 type: tosca.capabilities.Node
1254 type: org.openecomp.capabilities.metric.Ceilometer
1255 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1259 disk.device.write.bytes_server_cmaui:
1260 type: org.openecomp.capabilities.metric.Ceilometer
1261 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1265 disk.allocation_server_cmaui:
1266 type: org.openecomp.capabilities.metric.Ceilometer
1267 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1271 disk.write.requests_server_cmaui:
1272 type: org.openecomp.capabilities.metric.Ceilometer
1273 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1277 network.outgoing.packets.rate_cmaui_port_11:
1278 type: org.openecomp.capabilities.metric.Ceilometer
1279 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1283 binding_cmaui_port_11:
1284 type: tosca.capabilities.network.Bindable
1286 - org.openecomp.resource.cp.nodes.heat.network.contrailV2.VLANSubInterface
1290 memory.usage_server_cmaui:
1291 type: org.openecomp.capabilities.metric.Ceilometer
1292 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1296 disk.ephemeral.size_server_cmaui:
1297 type: org.openecomp.capabilities.metric.Ceilometer
1298 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1302 attachment_cmaui_port_11:
1303 type: tosca.capabilities.Attachment
1307 network.incoming.packets.rate_cmaui_port_11:
1308 type: org.openecomp.capabilities.metric.Ceilometer
1309 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1313 endpoint_server_cmaui:
1314 type: tosca.capabilities.Endpoint.Admin
1318 network.outgoing.bytes_cmaui_port_22:
1319 type: org.openecomp.capabilities.metric.Ceilometer
1320 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1324 disk.iops_server_cmaui:
1325 type: org.openecomp.capabilities.metric.Ceilometer
1326 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1330 network.incoming.packets_cmaui_port_11:
1331 type: org.openecomp.capabilities.metric.Ceilometer
1332 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1336 disk.device.iops_server_cmaui:
1337 type: org.openecomp.capabilities.metric.Ceilometer
1338 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1342 network.incoming.bytes_cmaui_port_11:
1343 type: org.openecomp.capabilities.metric.Ceilometer
1344 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.
1348 disk.read.bytes_server_cmaui:
1349 type: org.openecomp.capabilities.metric.Ceilometer
1350 description: A node type that includes the Metric capability indicates that it can be monitored using ceilometer.