c5977ee47216543f0877a5776da7b45bf069dee4
[policy/parent.git] / docs / clamp / acm / controlloop-architecture.rst
1 .. This work is licensed under a Creative Commons Attribution 4.0 International License.
2
3 .. _clamp-controlloop_architecture-label:
4
5 TOSCA Defined Control Loops: Architecture and Design
6 ####################################################
7
8
9 .. contents::
10     :depth: 4
11
12 The idea of using control loops to automatically (or autonomously) perform network management
13 has been the subject of much research in the Network Management research community, see
14 :download:`this paper <files/ControlLoops.pdf>` for some background. However, it is only with
15 the advent of ONAP that we have a platform that supports control loops for network management.
16 Before ONAP, Control Loops have been implemented by hard-coding components together and hard
17 coding logic into components. ONAP has taken a step forward towards automatic implementation
18 of Control Loops by allowing parameterization of Control Loops that work on the premise that
19 the Control Loops use a set of analytic, policy, and control components connected together in
20 set ways.
21
22 The goal of the work is to extend and enhance the current ONAP Control Loop support to provide
23 a complete open-source framework for Control Loops. This will enhance the current support to
24 provide TOSCA based Control Loop definition and development, commissioning and run-time management.
25 The participants that comprise a Control Loop and the metadata needed to link the participants
26 together to create a Control Loop are specified in a standardized way using the `OASIS TOSCA
27 modelling language <http://docs.oasis-open.org/tosca/TOSCA-Simple-Profile-YAML/>`_. The TOSCA
28 description is then used to commission, instantiate, and manage the Control Loops in the run
29 time system.
30
31 .. image:: images/01-controlloop-overview.png
32
33 1 Terminology
34 =============
35
36 This section describes the terminology used in the system.
37
38 1.1 Control Loop Terminology
39 ----------------------------
40
41 **Control Loop Type:** A definition of a Control Loop in the TOSCA language. This definition describes
42 a certain type of a control loop. The life cycle of instances of a Control Loop Type are managed
43 by CLAMP.
44
45 **Control Loop Instance:** An instance of a Control Loop Type. The life cycle of a Control Loop
46 Instance is managed by CLAMP. A Control Loop Instance is a set of executing elements on which
47 Life Cycle Management (LCM) is executed collectively. For example, a set of microservices may be
48 spawned and executed together to deliver a service. This collection of services is a control loop.
49
50 **Control Loop Element Type:** A definition of a Control Loop Element in the TOSCA language. This
51 definition describes a certain type of Control Loop Element for a control loop in a Control
52 Loop Type.
53
54 **Control Loop Element Instance:** A single entity executing on a participant, with its Life Cycle
55 being managed as part of the overall control loop. For example, a single microservice that is
56 executing as one microservice in a service.
57
58 **CLAMP Control Loop Runtime:** The CLAMP server that holds Control Loop Type definitions and manages
59 the life cycle of Control Loop Instances and their Control Loop Elements in cooperation with
60 participants.
61
62
63 1.2 Participant Terminology
64 ---------------------------
65
66 **Participant Type:** Definition of a type of system or framework that can take part in control
67 loops and a definition of the capabilities of that participant type. A participant advertises
68 its type to the CLAMP Control Loop Runtime.
69
70 **Participant:** A system or framework that takes part in control loops by executing Control Loop
71 Elements in cooperation with the CLAMP Control Loop Runtime. A participant chooses to partake
72 in control loops, to manage Control Loop Elements for CLAMP, and to receive, send and act on
73 LCM messages for the CLAMP runtime.
74
75 1.3 Terminology for Properties
76 ------------------------------
77
78 **Common Properties:** Properties that apply to all Control Loop Instances of a certain Control
79 Loop Type and are specified when a Control Loop Type is commissioned.
80
81 **Instance Specific Properties:** Properties that must be specified for each Control Loop Instance
82 and are specified when a Control Loop Instance is Initialized.
83
84 1.4 Concepts and their relationships
85 ------------------------------------
86
87 The UML diagram below shows the concepts described in the terminology sections above and how
88 they are interrelated.
89
90 .. image:: images/02-controlloop-concepts.png
91
92 The Control Loop Definition concepts describe the types of things that are in the system. These
93 concepts are defined at design time and are passed to the runtime in a TOSCA document. The
94 concepts in the Control Loop Runtime are created by the runtime part of the system using the
95 definitions created at design time.
96
97 .. _controlloop-capabilities:
98
99 2 Capabilities
100 ==============
101
102 We consider the capabilities of Control Loops at Design Time and Run Time.
103
104 At Design Time, three capabilities are supported:
105
106 #. **Control Loop Element Definition Specification.** This capability allows users to define Control
107    Loop Element Types and the metadata that can be used on and configured on a Control Loop Element
108    Type. Users also define the Participant Type that will run the Control Loop Element when it is
109    taking part in in a control loop. The post condition of an execution of this capability is that
110    metadata for a Control Loop Element Type is defined in the Control Loop Design Time Catalogue.
111
112 #. **Control Loop Element Definition Onboarding.** This capability allows external users and systems
113    (such as SDC or DCAE-MOD) to define the metadata that can be used on and configured on a Control
114    Loop Element Type and to define the Participant Type that will run the Control Loop Element when
115    it is taking part in in a control loop. The post condition of an execution of this capability
116    is that metadata for a Control Loop Element Type is defined in the Control Loop Design Time
117    Catalogue.
118
119 #. **Control Loop Type Definition.** This capability allows users and other systems to create Control
120    Loop Type definitions by specifying a set of Control Loop Element Definitions from those that
121    are available in the Control Loop Design Time Catalogue. These Control Loop Elements will
122    work together to form Control Loops. In an execution of this capability, a user specifies the
123    metadata for the Control Loop and specifies the set of Control Loop Elements and their Participant
124    Types. The user also selects the correct metadata sets for each participant in the Control Loop
125    Type and defines the overall Control Loop Type metadata. The user also specifies the Common
126    Property Types that apply to all instances of a control loop type and the Instance Specific
127    Property Types that apply to individual instances of a Control Loop Type. The post condition for
128    an execution of this capability is a Control Loop definition in TOSCA stored in the Control Loop
129    Design Time Catalogue.
130
131 .. note::
132     Once a Control Loop Definition is commissioned to the Control Loop Runtime and has been
133     stored in the Run Time Inventory, it cannot be further edited unless it is decommissioned.
134
135
136 At Run Time, the following participant related capabilities are supported:
137
138 #. **System Pre-Configuration.** This capability allows participants to register and deregister
139    with CLAMP. Participants explicitly register with CLAMP when they start. Control Loop Priming
140    is performed on each participant once it registers. The post condition for an execution of this
141    capability is that a participant becomes available (registration) or is no longer available
142    (deregistration) for participation in a control loop.
143
144 #. **Control Loop Priming on Participants.** A participant is primed to support a Control Loop Type.
145    Priming a participant means that the definition of a control loop and the values of Common
146    Property Types that apply to all instances of a control loop type on a participant are sent
147    to a participant. The participant can then take whatever actions it need to do to support
148    the control loop type in question. Control Loop Priming takes place at participant
149    registration and at Control Loop Commissioning. The post condition for an execution of this
150    capability is that all participants in this control loop type are commissioned, that is they
151    are prepared to run instances of their Control Loop Element types.
152
153
154 At Run Time, the following Control Loop Life Cycle management capabilities are supported:
155
156 #. **Control Loop Commissioning:** This capability allows version controlled Control Loop Type
157    definitions to be taken from the Control Loop Design Time Catalogue and be placed in the
158    Commissioned Control Loop Inventory. It also allows the values of Common Property Types
159    that apply to all instances of a Control Loop Type to be set. Further, the Control Loop
160    Type is primed on all concerned participants. The post condition for an execution of this
161    capability is that the Control Loop Type definition is in the Commissioned Control Loop
162    Inventory and the Control Loop Type is primed on concerned participants.
163
164 #. **Control Loop Instance Life Cycle Management:** This capability allows a Control Loop
165    Instance to have its life cycle managed.
166
167    #. **Control Loop Instance Creation:** This capability allows a Control Loop Instance to be
168       created. The Control Loop Type definition is read from the Commissioned Control Loop
169       Inventory and values are assigned to the Instance Specific Property Types defined for
170       instances of the Control Loop Type in the same manner as the existing CLAMP client does.
171       A Control Loop Instance that has been created but has not yet been instantiated on
172       participants is in state UNINITIALIZED. In this state, the Instance Specific Property Type
173       values can be revised and updated as often as the user requires. The post condition for an
174       execution of this capability is that the Control Loop instance is created in the
175       Instantiated Control Loop Inventory but has not been instantiated on Participants.
176
177    #. **Control Loop Instance Update on Participants:** Once the user is happy with the property
178       values, the Control Loop Instance is updated on participants and the Control Loop Elements
179       for this Control Loop Instance are initialized or updated by participants using the control
180       loop metadata. The post condition for an execution of this capability is that the Control
181       Loop instance is updated on Participants.
182
183    #. **Control Loop State Change:** The user can now order the participants to change the state
184       of the Control Loop Instance. If the Control Loop is set to state RUNNING, each participant
185       begins accepting and processing control loop events and the Control Loop Instance is set
186       to state RUNNING in the Instantiated Control Loop inventory. The post condition for an
187       execution of this capability is that the Control Loop instance state is changed on
188       participants.
189
190    #. **Control Loop Instance Monitoring:** This capability allows Control Loop Instances to be
191       monitored. Users can check the status of Participants, Control Loop Instances, and Control
192       Loop Elements. Participants report their overall status and the status of Control Loop
193       Elements they are running periodically to CLAMP. Clamp aggregates these status reports
194       into an aggregated Control Loop Instance status record, which is available for monitoring.
195       The post condition for an execution of this capability is that Control Loop Instances are
196       being monitored.
197
198    #. **Control Loop Instance Supervision:** This capability allows Control Loop Instances to be
199       supervised. The CLAMP runtime expects participants to report on Control Loop Elements
200       periodically. The CLAMP runtime checks that periodic reports are received and that each
201       Control Loop Element is in the state it should be in. If reports are missed or if a
202       Control Loop Element is in an incorrect state, remedial action is taken and notifications
203       are issued. The post condition for an execution of this capability is that Control Loop
204       Instances are being supervised by the CLAMP runtime.
205
206    #. **Control Loop Instance Removal from Participants:** A user can order the removal of a Control
207       Loop Instance from participants. The post condition for an execution of this capability is
208       that the Control Loop instance is removed from Participants.
209
210    #. **Control Loop Instance Deletion:** A user can order the removal of a Control Loop Instance
211       from the CLAMP runtime. Control Loop Instances that are instantiated on participants cannot
212       be removed from the CLAMP runtime. The post condition for an execution of this capability
213       is that the Control Loop instance is removed from Instantiated Control Loop Inventory.
214
215 #. **Control Loop Decommissioning:** This capability allows version controlled Control Loop Type
216    definitions to be removed from the Commissioned Control Loop Inventory. A Control Loop
217    Definition that has instances in the Instantiated Control Loop Inventory cannot be removed.
218    The post condition for an execution of this capability is that the Control Loop Type
219    definition removed from the Commissioned Control Loop Inventory.
220
221 .. note::
222     The system dialogues for run time capabilities are described in detail on the
223     :ref:`System Level Dialogues <system-level-label>` page.
224
225 .. _controlloop-instance-states:
226
227 2.1 Control Loop Instance States
228 --------------------------------
229
230 When a control loop definition has been commissioned, instances of the control loop can be
231 created, updated, and deleted. The system manages the lifecycle of control loops and control
232 loop elements following the state transition diagram below.
233
234 .. image:: images/03-controlloop-instance-states.png
235
236 3 Overall Target Architecture
237 =============================
238
239 The diagram below shows an overview of the architecture of TOSCA based Control Loop
240 Management in CLAMP.
241
242 .. image:: images/04-overview.png
243
244 Following the ONAP Reference Architecture, the architecture has a Design Time part and
245 a Runtime part.
246
247 The Design Time part of the architecture allows a user to specify metadata for participants.
248 It also allows users to compose control loops. The Design Time Catalogue contains the metadata
249 primitives and control loop definition primitives for composition of control loops. As shown
250 in the figure above, the Design Time component provides a system where Control Loops can be
251 designed and defined in metadata. This means that a Control Loop can have any arbitrary
252 structure and the Control Loop developers can use whatever analytic, policy, or control
253 participants they like to implement their Control Loop. At composition time, the user
254 parameterises the Control Loop and stores it in the design time catalogue. This catalogue
255 contains the primitive metadata for any participants that can be used to compose a Control
256 Loop. A Control Loop SDK is used to compose a Control Loop by aggregating the metadata for
257 the participants chosen to be used in a Control Loop and by constructing the references between
258 the participants. The architecture of the Control Loop Design Time part will be elaborated in
259 future releases.
260
261 Composed Control Loops are commissioned on the run time part of the system, where they are
262 stored in the Commissioned Control Loop inventory and are available for instantiation. The
263 Commissioning component provides a CRUD REST interface for Control Loop Types, and implements
264 CRUD of Control Loop Types. Commissioning also implements validation and persistence of incoming
265 Control Loop Types. It also guarantees the integrity of updates and deletions of Control Loop
266 Types, such as performing updates in accordance with semantic versioning rules and ensuring that
267 deletions are not allowed on Control Loop Types that have instances defined.
268
269 The Instantiation component manages the Life Cycle Management of Control Loop Instances and
270 their Control Loop Elements. It publishes a REST interface that is used to create Control Loop
271 Instances and set values for Common and Instance Specific properties. This REST interface is
272 public and is used by the CLAMP GUI. It may also be used by any other client via the public
273 REST interface. the REST interface also allows the state of Control Loop Instances to be changed.
274 A user can change the state of Control Loop Instances as described in the state transition
275 diagram shown in section 2 above. The Instantiation component issues update and state change
276 messages via DMaaP to participants so that they can update and manage the state of the Control
277 Loop Elements they are responsible for. The Instantiation component also implements persistence
278 of Control Loop Instances, control loop elements, and their state changes.
279
280 The Monitoring component reads updates sent by participants. Participants report on the
281 state of their Control Loop Elements periodically and in response to a message they have
282 received from the Instantiation component. The Monitoring component reads the contents of
283 the participant messages and persists their state updates and statistics records. It also
284 publishes a REST interface that publishes the current state of all Participants, Control
285 Loop Instances and their Control Loop Elements, as well as publishing Participant and
286 Control Loop statistics.
287
288 The Supervision component is responsible for checking that Control Loop Instances are correctly
289 instantiated and are in the correct state (UNINITIALIZED/READY/RUNNING). It also handles
290 timeouts and on state changes to Control Loop Instances, and retries and rolls back state
291 changes where state changes failed.
292
293 A Participant is an executing component that partakes in control loops. More explicitly, a
294 Participant is something that implements the Participant Instantiation and Participant
295 Monitoring messaging protocol over DMaaP for Life Cycle management of Control Loop Elements.
296 A Participant runs Control Loop Elements and manages and reports on their life cycle
297 following the instructions it gets from the CLAMP runtime in messages delivered over DMaaP.
298
299 In the figure above, five participants are shown. A Configuration Persistence Participant
300 manages Control Loop Elements that interact with the `ONAP Configuration Persistence Service
301 <https://docs.onap.org/projects/onap-cps/en/latest/overview.html>`_
302 to store common data. The DCAE Participant runs Control Loop Elements that manage DCAE
303 microservices. The Kubernetes Participant hosts the Control Loop Elements that are managing
304 the life cycle of microservices in control loops that are in a Kubernetes ecosystem. The
305 Policy Participant handles the Control Loop Elements that interact with the Policy Framework
306 to manage policies for control loops. A Controller Participant such as the CDS Participant
307 runs Control Loop Elements that load metadata and configure controllers so that they can
308 partake in control loops. Any third party Existing System Participant can be developed to
309 run Control Loop Elements that interact with any existing system (such as an operator's
310 analytic, machine learning, or artificial intelligence system) so that those systems can
311 partake in control loops.
312
313 4. Other Considerations
314 =======================
315
316 .. _management-cl-instance-configs:
317
318 4.1 Management of Control Loop Instance Configurations
319 ------------------------------------------------------
320
321 In order to keep management of versions of the configuration of control loop instances
322 straightforward and easy to implement, the following version management scheme using
323 semantic versioning is implemented. Each configuration of a Control Loop Instance and
324 configuration of a Control Loop Element has a semantic version with 3 digits indicating
325 the **major.minor.patch** number of the version.
326
327 .. note::
328     A **configuration** means a full set of parameter values for a Control Loop Instance.
329
330 .. image:: images/05-upgrade-states.png
331
332 Change constraints:
333
334 #. A Control Loop or Control Loop Element in state **RUNNING** can be changed to a higher patch
335    level or rolled back to a lower patch level. This means that hot changes that do not
336    impact the structure of a Control Loop or its elements can be executed.
337
338 #. A Control Loop or Control Loop Element in state **PASSIVE** can be changed to a higher
339    minor/patch level or rolled back to a lower minor/patch level. This means that structural
340    changes to Control Loop Elements that do not impact the Control Loop as a whole can be
341    executed by taking the control loop to state **PASSIVE**.
342
343 #. A Control Loop or Control Loop Element in state **UNINITIALIZED** can be changed to a higher
344    major/minor/patch level or rolled back to a lower major/minor/patch level. This means
345    that where the structure of the entire control loop is changed, the control loop must
346    be uninitialized and reinitialized.
347
348 #. If a Control Loop Element has a **minor** version change, then its Control Loop Instance
349    must have at least a **minor** version change.
350
351 #. If a Control Loop Element has a **major** version change, then its Control Loop Instance
352    must have a **major** version change.
353
354 4.2 Scalability
355 ---------------
356
357 The system is designed to be inherently scalable. The CLAMP runtime is stateless, all state
358 is preserved in the Instantiated Control Loop inventory in the database. When the user
359 requests an operation such as an instantiation, activation, passivation, or an uninitialization
360 on a Control Loop Instance, the CLAMP runtime broadcasts the request to participants over
361 DMaaP and saves details of the request to the database. The CLAMP runtime does not directly
362 wait for responses to requests.
363
364 When a request is broadcast on DMaaP, the request is asynchronously picked up by participants
365 of the types required for the Control Loop Instance and those participants manage the life
366 cycle of its control loop elements. Periodically, each participant reports back on the status
367 of operations it has picked up for the Control Loop Elements it controls, together with
368 statistics on the Control Loop Elements over DMaaP. On reception of these participant messages,
369 the CLAMP runtime stores this information to its database.
370
371 The participant to use on a control loop can be selected from the registered participants
372 in either of two ways:
373
374 **Runtime-side Selection:** The CLAMP runtime selects a suitable participant from the list of
375 participants and sends the participant ID that should be used in the Participant Update message.
376 In this case, the CLAMP runtime decides on which participant will run the Control Loop Element
377 based on a suitable algorithm. Algorithms could be round robin based or load based.
378
379 **Participant-side Selection:** The CLAMP runtime sends a list of Participant IDs that may be used
380 in the Participant Update message. In this case, the candidate participants decide among
381 themselves which participant should host the Control Loop Element.
382
383 This approach makes it easy to scale Control Loop life cycle management. As Control Loop
384 Instance counts increase, more than one CLAMP runtime can be deployed and REST/supervision
385 operations on Control Loop Instances can run in parallel. The number of participants can
386 scale because an asynchronous broadcast mechanism is used for runtime-participant communication
387 and there is no direct connection or communication channel between participants and CLAMP
388 runtime servers. Participant state, Control Loop Instance state, and Control Loop Element
389 state is held in the database, so any CLAMP runtime server can handle operations for any
390 participant. Because many participants of a particular type can be deployed and participant
391 instances can load balance control loop element instances for different Control Loop Instances
392 of many types across themselves using a mechanism such as a Kubernetes cluster.
393
394
395 4.3 Sandboxing and API Gateway Support
396 --------------------------------------
397
398 At runtime, interaction between ONAP platform services and application microservices are
399 relatively unconstrained, so interactions between Control Loop Elements for a given Control
400 Loop Instance remain relatively unconstrained. A
401 `proposal to support access-controlled access to and between ONAP services
402 <https://wiki.onap.org/pages/viewpage.action?pageId=103417456>`_
403 will improve this. This can be complemented by intercepting and controlling services
404 accesses between Control Loop Elements for Control Loop Instances for some/all Control
405 Loop types.
406
407 API gateways such as `Kong <https://konghq.com/kong/>`_ have emerged as a useful technology
408 for exposing and controlling service endpoint access for applications and services. When a
409 Control Loop Type is onboarded, or when Control Loop Instances are created in the Participants,
410 CLAMP can configure service endpoints between Control Loop Elements to redirect through an
411 API Gateway.
412
413 Authentication and access-control rules can then be dynamically configured at the API gateway
414 to support constrained access between Control Loop Elements and Control Loop Instances.
415
416 The diagram below shows the approach for configuring API Gateway access at Control Loop
417 Instance and Control Loop Element level.
418
419 .. image:: images/06-api-gateway-sandbox.png
420
421 At design time, the Control Loop type definition specifies the type of API gateway configuration
422 that should be supported at Control Loop and Control Loop Element levels.
423
424 At runtime, the CLAMP can configure the API gateway to enable (or deny) interactions between
425 Control Loop Instances and individually for each Control Loop Element. All service-level
426 interactions in/out of a Control Loop Element, except that to/from the API Gateway, can be
427 blocked by networking policies, thus sandboxing a Control Loop Element and an entire Control
428 Loop Instance if desired. Therefore, a Control Loop Element will only have access to the APIs
429 that are configured and enabled for the Control Loop Element/Instance in the API gateway.
430
431 For some Control Loop Element Types the Participant can assist with service endpoint
432 reconfiguration, service request/response redirection to/from the API Gateway, or
433 annotation of requests/responses.
434
435 Once the Control Loop instance is instantiated on participants, the participants configure
436 the API gateway with the Control Loop Instance level configuration and with the specific
437 configuration for their Control Loop Element.
438
439 Monitoring and logging of the use of the API gateway may also be provided. Information and
440 statistics on API gateway use can be read from the API gateway and passed back in monitoring
441 messages to the CLAMP runtime.
442
443 Additional isolation and execution-environment sandboxing can be supported depending on the
444 Control Loop Element Type. For example: ONAP policies for given Control Loop Instances/Types
445 can be executed in a dedicated PDP engine instances; DCAE or K8S-hosted services can executed
446 in isolated namespaces or in dedicated workers/clusters; etc..
447
448
449 5 APIs and Protocols
450 ====================
451
452 The APIs and Protocols used by CLAMP for Control Loops are described on the pages below:
453
454 #. :ref:`System Level Dialogues <system-level-label>`
455 #. :ref:`The CLAMP Control Loop Participant Protocol <controlloop-participant-protocol-label>`
456 #. :ref:`REST APIs for CLAMP Control Loops <controlloop-rest-apis-label>`
457
458
459 6 Design and Implementation
460 ===========================
461
462 The design and implementation of TOSCA Control Loops in CLAMP is described for each executable entity on the pages below:
463
464 #. :ref:`The CLAMP Control Loop Runtime Server <clamp-controlloop-runtime>`
465 #. :ref:`CLAMP Control Loop Participants <clamp-controlloop-participants>`
466 #. :ref:`Managing Control Loops using The CLAMP GUI <clamp-gui-controlloop>`